[Comparison of four digital and one conventional radiographic image systems for the chest in a patient study with subsequent system optimization].

PURPOSE: Using a patient study to prove the clinical relevance of a comparison of five different radiographic systems for the chest conducted with an anthropomorphic chest phantom. Depending on the results, it was tested whether the performance of a modern digital system with a transparent imaging plate can be improved by changing the post-processing of the image. METHOD: Chest radiographs of patients were taken with a CsI/aSi-flat panel detector (FDR), transparent imaging plate (tDLR), selenium drum detector (DSR), conventional storage phosphor plate (DLR) and asymmetrical screen-film-system (aFFS), and compared using image criteria scoring (ICS) and visual grading analysis (VGA) for anatomical structures (modified criterions of the EUR 16 260 EN guidelines). After optimizing the post processing, the images of the tDLR-system were evaluated once more in a phantom ROC study and patient VGA study. RESULTS: The flat panel detector-system proved to meet best the anatomical image quality criteria, followed by DSR, tDLR, aFFS and DLR. The modified post processing of the tDLR-images resulted in a significantly better detection of simulated pathological lung-structures, but improved the perceptibility of anatomical structures only slightly. CONCLUSIONS: The results of the patient VGA study and the phantom ROC study are similar and considered valid. The new digital imaging systems with flat panel detector and transparent imaging plate provide the best image quality of the tested radiographic devices for chest imaging, assuming that all system components are attuned and optimized for the type of structure to be detected. Image processing is of primary importance for system optimization.

Humans↗

Aspirin and clopidogrel taken until 2 days prior to coronary artery bypass graft surgery is associated with increased postoperative drainage loss.

OBJECTIVE: Platelet aggregation inhibitors, such as aspirin and clopidogrel, are associated with increased bleeding in patients undergoing cardiac surgery with cardiopulmonary bypass. We investigated the impact of time between the last intake of aspirin and clopidogrel before CABG surgery and drainage loss, transfusion requirements and rate of reoperation. PATIENTS AND METHODS: The records of patients who had coronary artery bypass graft surgery (CABG) were reviewed for intake of aspirin and clopidogrel within 7 days prior to surgery. Drainage loss, transfusion requirements and rate of reoperation for bleeding within 5 days after the operation, were recorded. RESULTS: Out of 261 analysed patients, 225 patients (86.2 %) had no anti-platelet medication and 36 patients (13.8 %) were on aspirin and clopidogrel. Aspirin and clopidogrel, taken all until 2 days prior to operation, were associated with a significantly higher postoperative blood loss (1840 mL [1230 - 3710] vs. 280 mL [185 - 765], p = 0.005 for one day and 850 mL [345 - 1725] vs. 277 mL [165 - 778], p = 0.026, for 2 days prior to surgery). The trend showed that patients in the study group received more platelet concentrates (PC: 5.3 % vs. 13.9 %, p = 0.067). The rate of reoperation for bleeding was not different ( p = 0.25). CONCLUSION: Aspirin and clopidogrel up to 2 days prior to CABG were associated with a significantly higher postoperative drainage loss.

Aged↗

Assessment and optimisation of the image quality of chest-radiography systems.

A complete evaluation strategy had been developed for thoracic X-ray imaging. It has been validated by investigating five chest-radiography systems, two of these systems after optimising image processing. The systems were a screen-film combination, a selenium drum, a conventional and a transparent imaging plate and a Cs/I-based flat panel detector (the two latter ones have been optimised using different post processing). At first all detectors have been characterised using physical parameters like DQE and MTF. After that all systems have been evaluated by human observer studies using anatomy in clinical images (VGA, ICS) and added pathological structures in thoracic phantom images (ROC). The ranking of the image quality of the systems was nearly the same in all studies. There was a similar assessment of main image quality parameters like spatial resolution, dynamic range and MTF. The modification of image post processing changed the visibility of pathological structures more than the visualisation of the anatomical criteria. The assessment of the clinical image quality has to be done for anatomical structures, and the recognition of pathological structures has to be evaluated.

Cesium↗

[Chest radiography: ROC phantom study of four different digital systems and one conventional radiographic system].

PURPOSE: To compare the diagnostic quality of five different radiographic systems used in chest radiography for visualization of differently configured, clinically relevant pathologic pulmonary structures. MATERIALS AND METHODS: Four digital detector systems using as detection unit a CsI/aSi-based flat panel detector, a transparent imaging plate, a selenium detector and a conventional storage phosphor plate were analyzed for this study, as well as an asymmetrical film-screen system. The analyzed imaging material consisted of radiographs of an anthropomorphic chest-phantom with superimposed simulated pulmonary structures. The images were evaluated for different pathologic structures by a newly developed multiple structure ROC (ms-ROC). RESULTS: The performance of each system was found to have a strong structure-related variability. The flat panel detector system had the best overall performance. The theoretical advantage of the 4k-matrix of the transparent imaging plate over the 3k-matrix of the flat panel detector was only confirmed for reticular structures. CONCLUSIONS: In addition to comparing the image quality of the different systems, this study shows that the performance of a radiographic system depends on the structure to be analyzed. The modified ROC (ms-ROC) provides valid results with less effort.

Humans↗

[Optimized image processing with modified preprocessing of image data sets of a transparent imaging plate by way of the lateral view of the cervical spine].

PURPOSE: To improve the diagnostic quality of lateral radiographs of the cervical spine by pre-processing the image data sets produced by a transparent imaging plate with both-side reading and to evaluate any possible impact on minimizing the number of additional radiographs and supplementary investigations. MATERIAL AND METHODS: One hundred lateral digital radiographs of the cervical spine were processed with two different methods: processing of each data set using the system-imminent parameters and using the manual mode. The difference between the two types of processing is the level of the latitude value. Hard copies of the processed images were judged by five radiologists and three neurosurgeons. The evaluation applied the image criteria score (ICS) without conventional reference images. RESULTS: In 99 % of the lateral radiographs of the cervical spine, all vertebral bodies could be completed delineated using the manual mode, but only 76 % oft the images processed by the system-imminent parameters showed all vertebral bodies. Thus, the manual mode enabled the evaluation of up to two additional more caudal vertebral bodies. The manual mode processing was significantly better concerning object size and processing artifacts. This optimized image processing and the resultant minimization of supplementary investigations was calculated to correspond to a theoretical dose reduction of about 50 %. CONCLUSION: The introduction of optimized organ programs for the upper and lower cervical spine based on the 12-bit data of the images should improve the evaluation of the lateral radiograph of the cervical spine without reducing the latitude value.

Cervical Vertebrae↗

Risk factors for prolonged ventilation after cardiac surgery using APACHE II, SAPS II, and TISS: comparison of three different models.

OBJECTIVE: To identify the risk for prolonged mechanical ventilation in cardiac surgical patients. DESIGN: Prospective study with retrospective combination of a second database. PATIENTS: Six hundred and eighty-seven patients after cardiac surgery over a period of 12 months. MEASUREMENTS: Demographic data were recorded preoperatively, and surgical procedures intraoperatively using a surgical database designed for quality control. Length of ICU and hospital stay, and hospital outcome were recorded. Severity of illness was assessed daily using APACHE II, SAPS II, and Organ Failure Score. Intensity of treatment and nursing care was monitored by means of the Therapeutic Intervention Scoring System (TISS). Univariate and multivariate analyses were performed using logistic regression. The predictive value of the identified variables was tested by the Wilcoxon test using the receiver operating characteristic curve. MAIN RESULTS: Sixty-two patients (9.0%) were ventilated for > 48 h and accounted for 42.8% of the total costs in the ICU. The pre- and intraoperatively collected data produced a model with weak predictive capacity for prolonged ventilation [area under curve (AUC) 73.22 and 71.08, respectively]. The use of TISS and SAPS postoperatively resulted in an effective model of prediction (AUC 93.76). Adding the occurrence of reoperation, reintubation, emergency transfusion, intraaortic balloon pumping, and need for total parenteral nutrition to the model further improved its predictive capacity (AUC 94.74). CONCLUSIONS: The present results strongly suggest that data collected postoperatively using established scoring systems as well as documented events of high clinical impact for risk assessment and quality control are reliable predictors of prolonged ventilation.

APACHE↗

Downward movement of syringe pumps reduces syringe output.

We studied how lowering a syringe pump and changing the outflow pressure could affect syringe pump output. We experimentally reduced the height of three different syringe pump systems by 80 cm (adult setting) or 130 cm (neonatal setting), as can happen clinically, using five flow rates. We measured the time of backward flow, no flow and the total time without flow. An exponential negative correlation was present between infusion rate and time without flow (r2=0.809 to 0.972, P<0.01). Minimum flow rates of 4.4 and 2.6 ml h(-1) respectively were calculated to give 60 and 120 s without infusion. The compliance of the different syringe pumps and their infusion systems was linearly correlated with the effective time without infusion (r2=0.863, P<0.05). We conclude that the height of the syringe pumps should not be changed during transportation. If vertical movement of the syringe pump is necessary, the drugs should be diluted so that the flow rate is at least 5 ml h(-1).

Adult↗

[Paraproctic fistula in acetabulum loosening after implantation of a total hip endoprosthesis. A rare complication].

In this paper we present the unusual case of a fistula after implantation of a total hip prosthesis. In a 75-year old woman with a fracture of the thigh bone, we observed a paraproctic fistula 42 months after implantation of a total hip prosthesis. To our knowledge there have been no such cases reported with this complication. Thus, we wound like to demonstrate the progress of the illness, the first symptoms, and the kind and success of the treatment.

Acetabulum↗