PubMed Health⌕ Search

Biomedical subjects

U Resch-Genger

Publications and source records attributed to U Resch-Genger.

9 recordsLinked to original sources

Bifunctional charge transfer operated fluorescent probes with acceptor and donor receptors. 1. Biphenyl-type sensor molecules with protonation-induced anti-energy gap rule behavior.

On the basis of biphenyl (b) type molecules bpb-R substituted with a 2,2':6',2' '-terpyridine acceptor (bp) and either amino-type donor receptors (R = dimethylamino (DMA), A15C5 = monoaza-15-crown-5) or nonbinding substituents (R = CF(3), H, OMe) of various donor strengths, we developed a family of charge transfer (CT) operated monofunctional and bifunctional fluorescent sensors for protons and metal ions. These molecules are designed to communicate the interaction of an analyte with the acceptor and the donor receptor differing in basicity and cation selectivity by clearly distinguishable spectral shifts and intensity modulations in absorption and in emission as well as in fluorescence lifetime. From the dependence of the fluorescence spectra, fluorescence quantum yields, and fluorescence lifetimes of bpb-R on solvent polarity and proton concentration, the photophysics of bpb-R and their protonated analogues can be shown to be governed by the relaxation to a CT state of forbidden nature and by the switching between anti-energy and energy gap law type behaviors. This provides the basis for analytically favorable red shifted emission spectra in combination with comparatively high fluorescence quantum yields. Accordingly, bpb-H and bpb-OMe are capable of ratiometric emission signaling of protons. bpb-DMA reveals a protonation-induced ON-OFF-ON switching of its emission.

Journal Article↗

Bifunctional charge transfer operated fluorescent probes with acceptor and donor receptors. 2. Bifunctional cation coordination behavior of biphenyl-type sensor molecules incorporating 2,2':6',2' '-terpyridine acceptors.

Based on donor (D)-acceptor (A) biphenyl (b) type molecules, a family of fluorescent reporters with integrated acceptor receptors and noncoordinating and coordinating donor substituents of varying strength has been designed for ratiometric emission sensing and multimodal signaling of metal ions and protons. In part 2 of this series on such charge transfer (CT) operated mono- and bifunctional fluorescent devices, the cation coordination behavior of the sensor molecules bpb-R equipped with a proton- and cation-responsive 2,2':6',2' '-terpyridine (bp) acceptor and either amino-type donor receptors (R = DMA, A15C5 = monoaza-15-crown-5) or nonbinding substituents (R = CF(3), H, OMe) is investigated employing the representative metal ions Na(I), Ca(II), Zn(II), Hg(II), and Cu(II) and steady-state and time-resolved fluorometry. The bpb-R molecules, the spectroscopic behavior and protonation behavior of which have been detailed in part 1 of this series, present rare examples for CT-operated bifunctional fluorescent probes that can undergo consecutive and/or simultaneous analyte recognition. The analyte-mediated change of the probes' intramolecular CT processes yields complexation site- and analyte-specific outputs, i.e., absorption and fluorescence modulations in energy, intensity, and lifetime. As revealed by the photophysical studies of the cation complexes of these fluoroionophores and the comparison to other neutral and charged D-A biphenyls, the spectroscopic properties of the acceptor chelates of bpb-R and A- and D-coordinated bpb-R are governed by CT control of an excited-state barrier toward formation of a forbidden charge transfer state, by the switching between analytically favorable anti-energy and common energy gap law type behavior, and by the electronic nature of the ligated metal ion. This accounts for the astonishingly high fluorescence quantum yields of the acceptor chelates of bpb-R equipped with weak or medium-sized donors and the red emission of D- and A-coordinated bpb-R observed for nonquenching metal ions.

Biphenyl Compounds↗

The Calibration Kit Spectral Fluorescence Standards--a simple and certified tool for the standardization of the spectral characteristics of fluorescence instruments.

With the Calibration Kit Spectral Fluorescence Standards BAM-F001-BAM-F005, we developed a simple tool for the characterization of the relative spectral responsivity and the long-term stability of the emission channel of fluorescence instruments under routine measurement conditions thereby providing the basis for an improved comparability of fluorescence measurements and eventually standardization. This first set of traceable fluorescence standards, which links fluorescence measurements to the spectral radiance scale in the spectral range of 300-770 nm and has been optimized for spectrofluorometers, can be employed for different measurement geometries and can be adapted to different fluorescence techniques with proper consideration of the underlying measurement principles.

Calibration↗

CT-operated bifunctional fluorescent probe based on a pretwisted donor-donor-biphenyl.

Taking into account the structural requirements for TICT-type sensor molecules, a general synthetic route to derive pH and cation-responsive pretwisted donor (D)-donor (D) biphenyls (b) equipped with donor receptors is developed and a first model compound containing a mono aza-15-crown-5 and a DMA receptor is synthesized, see Scheme 1. The spectroscopic properties of this new bifunctional D-D biphenyl are studied in the non-polar and polar solvents cyclohexane, acetonitrile, and methanol. Protonation as well as complexation studies are performed with the representative metal ions Na(I), K(I), Ca(II), Ag(I), Zn(II), Cd(II), Hg(II), and Pb(II) to reveal the potential of this molecule for communication of whether none, only one, or both binding sites are engaged in analyte coordination by spectroscopically distinguishable outputs. The results are compared to those obtained with closely related donor (D)-acceptor (A) substituted biphenyl-type sensor molecules and are discussed within the framework of neutral and ionic D-A biphenyls.

Biphenyl Compounds↗

Fluorescence spectroscopic studies on plasma-chemically modified polymer surfaces with fluorophore-labeled functionalities.

Molecular engineering of polymer surfaces that includes the attachment of functional molecules to existing or previously generated reactive chemical groups like e.g., -OH, -NH2, or -CHO requires simple strategies and tools for the controlled generation of surface functionalities and their derivatization as well as for their identification and eventually quantification. Here, we systematically investigate the plasma-chemical surface modification of polypropylene films in combination with dansyl labeling chemistry and conventional, yet costly, XPS and highly sensitive fluorescence spectroscopy for the detection of surface groups. Based on these results, the potential of and requirements on the fluorometric characterization and quantification of surfaces functionalities are discussed.

Fluorescent Dyes↗

Traceability in fluorometry--Part I: Physical standards.

The inter-instrument, inter-laboratory, and long-term comparability of fluorescence data requires the correction of the measured emission and excitation spectra for the wavelength- and polarization-dependent spectral irradiance of the excitation channel at the sample position and the spectral responsivity of the emission channel employing procedures that guarantee traceability to the respective primary standards. In this respect the traceability chain of fluorometry is discussed from a radiometrist's point of view. This involves, in a first step, the realization of the spectral radiance scale, based on the blackbody radiator and electron storage ring, and the spectral responsivity scale, based on the cryogenic radiometer and their control via key comparisons of the national metrology institutes. In a second step, the characterization including state-of-the art uncertainties of the respective source and detector transfer standards such as tungsten strip lamps, integrating sphere radiators, and trap detectors used to disseminate these radiometric quantities to users of spectroscopic techniques is presented.

Journal Article↗

Traceability in fluorometry: Part II. Spectral fluorescence standards.

The need for the traceable characterization of fluorescence instruments is emphasized from a chemist's point of view, focusing on spectral fluorescence standards for the determination of the wavelength- and polarization-dependent relative spectral responsivity and relative spectral irradiance of fluorescence measuring systems, respectively. In a first step, major sources of error of fluorescence measurements and instrument calibration are revealed to underline the importance of this issue and to illustrate advantages and disadvantages of physical and chemical transfer standards for generation of spectral correction curves. Secondly, examples for sets of traceable chemical emission and excitation standards are shown that cover a broad spectral region and simple procedures for the determination of corrected emission spectra with acceptable uncertainties are presented. With proper consideration of the respective measurement principle and geometry, these dye-based characterization procedures can be not only applied to spectrofluorometers but also to other types of fluorescence measuring systems and even to Raman spectrometers.

Journal Article↗

How to improve quality assurance in fluorometry: fluorescence-inherent sources of error and suited fluorescence standards.

The scope of this paper is to illustrate the need for an improved quality assurance in fluorometry. For this purpose, instrumental sources of error and their influences on the reliability and comparability of fluorescence data are highlighted for frequently used photoluminescence techniques ranging from conventional macro- and microfluorometry over fluorescence microscopy and flow cytometry to microarray technology as well as in vivo fluorescence imaging. Particularly, the need for and requirements on fluorescence standards for the characterization and performance validation of fluorescence instruments, to enhance the comparability of fluorescence data, and to enable quantitative fluorescence analysis are discussed. Special emphasis is dedicated to spectral fluorescence standards and fluorescence intensity standards.

Journal Article↗

Cu(II)- and Hg(II)-induced modulation of the fluorescence behavior of a redox-active sensor molecule.

Here, we report on a fluorescent 1,2,4-thiadiazole derivative (oxidized form) and its reduced form, the corresponding iminoyl thiourea. The thiadiazole displays a strong modulation of its fluorescence behavior, selectively upon addition of Cu(II), while the iminoyl thiourea functions as a chemodosimeter for Hg(II). Additionally, the Cu(II)-thiadiazole complex is characterized by HRMS, and the Hg(II)-induced desulfurization of the iminoyl thiourea is monitored by mass spectrometry.

Journal Article↗