PubMed Health⌕ Search

Biomedical subjects

U Sinha

Publications and source records attributed to U Sinha.

69 records · Page 4Linked to original sources

Chloral hydrate induced haploidization in Aspergillus nidulans.

This is the first report of induction of haploidization in Aspergillus nidulans by chloral hydrate, which is an efficient polyploidizing agent for higher plants and a psychotropic drug for man. A new procedure has been described to isolate haploids from diploids with a very high frequency, as compared to p-fluorophenylalanine, which is generally used for this purpose.

Aspergillus nidulans↗

MR imaging signal response to sustained stimulation in human visual cortex.

The response of signal intensity to transient (on-off) motor and sensory stimulation has been well studied; however, the dependence of signal response on the duration of stimulus requires further characterization. The objective of this study was to determine the time course of signal response in the human visual cortex to prolonged, sustained stimulation and to examine possible contributory physiologic mechanisms. Nine healthy volunteers underwent magnetic resonance (MR) imaging during sustained visual stimulation with light-proof binocular goggles. With photic stimulation, activation was observed in all subjects as an increase in signal intensity of the visual cortex. With sustained stimulation, a gradual decrease in signal intensity was subsequently observed, with progression toward an apparent steady state. Correlation with positron emission tomographic, MR spectroscopic, and visual evoked-potential data suggests that the initial uncoupling of cerebral blood flow and oxidative metabolism with a neuronal activation burst may represent a transient phenomenon. This quick-response phase may proceed to an equilibrium coupling of flow and oxidative metabolism, with a gradual normalization of venous deoxyhemoglobin levels and signal intensity.

Adult↗

Black blood dual phase turbo FLASH MR imaging of the heart.

An MR imaging scheme for dark blood cardiac images acquired simultaneously in end diastolic and end systolic phases, in breath-hold times, is presented. The sequence consists of a magnetization preparation period followed by two segmented k-space acquisitions. Image quality was investigated with respect to different sequence parameters (optimal values are indicated in brackets): (a) echo time (TE)/repetition time (TR)/ flip angle (FA) (3/6.2 msec/20 degrees); (b) number of lines/ segments in the acquisition window (11 lines/segment); (c) location of acquisition windows and inversion time; and (d) thickness of slice "reinverted" during preparation (1.53 times the acquisition slice thickness). The image quality of the basal slices at end systole was critically dependent on the last parameter. High quality short axis views of the heart, with good blood signal suppression, were acquired with the optimized sequence on four volunteers from apex to base at two phases in 10 breath-holds.

Blood↗

High speed diffusion imaging in the presence of eddy currents.

This paper describes two schemes for fast diffusion imaging on a 1.5T MRI unit with unshielded gradients and 10-mT/m gradient system. The prepared longitudinal magnetization is sampled by a turbo fast low-angle shot (FLASH) sequence. The first scheme involves modifications to a diffusion-weighted driven-equilibrium preparation sequence that yields quantitative diffusion imaging. The second scheme consists of four 90 degree pulses that form the preparatory period with diffusion gradients applied between the first and last two 90 degrees pulses. Sufficient time is allowed between the diffusion gradients and the beginning of the echo readout to allow eddy currents to decay to an acceptable level. Phantom studies show agreement between diffusion coefficients in the literature with those determined using the above schemes. The potential application of these sequences in monitoring temperature is demonstrated in phantoms. Artifact-free quantitative diffusion-weighted images of the brain using the second scheme are presented.

Algorithms↗

Segmentation strategies for breast tumors from dynamic MR images.

This paper describes two semiautomated methods of segmentation of breast tumors from dynamic MR images obtained subsequent to administration of gadopentate dimeglumine. The first method, based on temporal correlation, generates a similarity map from the dynamic scans in which the value of each pixel is determined by its temporal similarity to a reference region of interest. The second method uses multispectral analysis and generates a feature map from a scatterplot of pixel intensities in the pre- and postcontrast images. The segmentation methods were tested on malignant and benign breast lesions in 11 patients with a range of tumor volumes and percentage contrast enhancement. The accuracy of both segmentation techniques and reproducibility of the multispectral method were investigated. A comparison of the two methods established that the temporal correlation method was superior based on accuracy, extent of user interaction, and speed of segmentation.

Breast Neoplasms↗

Phase imaging on a .2-T MR scanner: application to temperature monitoring during ablation procedures.

Proton phase shift imaging methods with keyholing were developed to rapidly monitor temperature during MR-guided radiofrequency (RF) interventional procedures on a .2-T open configuration scanner. Temperature calibration was performed on thermally controlled gel phantom and ex vivo bovine liver samples. Keyholing methods were implemented for rapid imaging and tested both in simulation experiments and in the gel phantom. Phase drifts from extraneous sources were monitored and compensated for using reference phantoms. Sequence parameters TE, TR, and flip angle (FA) were optimized for maximum temperature sensitivity and minimum noise. Reduction of phase noise from coupling of the magnetic field to external perturbations using navigator-echo-based correction schemes were also investigated. The extraneous phase drifts from the magnet could be minimized by keeping the electromagnet on continuously. Navigator echo corrected keyholed FLASH sequences (TE = 30 msec, TR = 60 msec, FA = 40 degrees, 64 x 128 matrix) were used to monitor the RF lesioning process in gel phantoms yielding images every 4 seconds with a temperature sensitivity of .015 ppm/degree C. RF ablation in the bovine tissue was monitored using navigator-echo-corrected keyholed fast low angle shot (FLASH) sequences (TE = 30 msec, TR = 100 msec, FA = 40 degrees, 128 x 256 matrix) with a temporal resolution of 13 seconds and a temperature sensitivity of .007 ppm/degree C. The results indicate that monitoring of an RF ablation procedure by mapping temperature with sufficient temporal resolution is possible using phase images of FLASH sequences on a .2-T open scanner.

Animals↗

Pulse sequence optimization for use with a biopsy needle in MRI.

The purpose of this study was to assess the degree of conspicuity and amount of field distortion caused by a biopsy needle designed specifically for use in MRI studies. Toward this, a number of pulse sequences including spin and field echo were used. Parameters such as field of view, strength of read gradient, direction of read gradient, echo time and slice thickness were varied. The effect of these manipulations on needle visualization was studied. Partial voluming errors with thicker slices decreased needle conspicuity. Smaller field of view improved needle visualization as a result of magnification effect. Shallow read gradient strengths also increased needle conspicuity. Increased image artifacts were noted on field-echo sequences compared to spin echo. This effect increased with longer echo times. This reflects T2* effects on field-echo images.

Biopsy, Needle↗

Effect of field strength on susceptibility artifacts in magnetic resonance imaging.

In magnetic resonance imaging susceptibility artifacts occur at the interface of substances with large magnetic susceptibility differences, resulting in geometric distortions of the image at those boundaries. The susceptibility artifacts are often subtle on clinical images and if not carefully examined they may lead to misdiagnosis. Magnetic susceptibility artifacts are prevalent on the boundary of air-containing paranasal sinuses, as well as bone-soft tissue interfaces in the spinal canal. The appearance of these artifacts on images from three different magnetic field strength instruments, 0.3, 0.5, and 1.5 Tesla were studied. T1- and T2-weighted spin echo and gradient recalled echo pulse sequences were selected to image a water phantom containing substances of varying susceptibilities. The effects were also studied in MR images of the head in a normal human volunteer. At any given field strength the artifacts were more prominent in the gradient echo imaging than in the corresponding spin echo pulse sequence. As expected, the distortions were also greater at higher field strengths. The results in human subjects paralleled the findings in the phantom study.

Head↗

PACS database architecture and design.

PACS (Picture Archiving and Communication Systems) database design requires careful understanding of the data and processing needs of radiologists, referring physicians, radiology staff, administrators, and researchers. Due to access requirements, the physical implementation for the management of small text data sets differs from the implementation strategy for large image data sets (centralized vs. distributed storage strategies). In this paper we discuss the database structure, storage architecture, file placement strategies, and administration considerations of the UCLA PACS.

Database Management Systems↗

Teleradiology as a foundation for an enterprise-wide health care delivery system.

An effective, integrated telemedicine system has been developed that allows (a) teleconsultation between local primary health care providers (primary care physicians and general radiologists) and remote imaging subspecialists and (b) active patient participation related to his or her medical condition and patient education. The initial stage of system development was a traditional teleradiology consultation service between general radiologists and specialists; this established system was expanded to include primary care physicians and patients. The system was developed by using a well-defined process model, resulting in three integrated modules: a patient module, a primary health care provider module, and a specialist module. A middle agent layer enables tailoring and customization of the modules for each specific user type. Implementation by using Java and the Common Object Request Broker Architecture standard facilitates platform independence and interoperability. The system supports (a) teleconsultation between a local primary health care provider and an imaging subspecialist regardless of geographic location and (b) patient education and online scheduling. The developed system can potentially form a foundation for an enterprise-wide health care delivery system. In such a system, the role of radiologist specialists is enhanced from that of a diagnostician to the management of a patient's process of care.

Appointments and Schedules↗

Image content extraction: application to MR images of the brain.

A system for automatically extracting image content features was developed that combines registration to a labeled atlas with natural language processing of free-text radiology reports. The system was then tested with T1-weighted, spoiled gradient-echo magnetic resonance (MR) imaging studies of the brain performed in nine patients. The locations of 599 structures were visually assessed by an experienced radiologist and compared with the locations indicated by automated output. The in-plane accuracy of the contours was subjectively evaluated as either good, moderate, or poor. The criterion for classifying a structure as correctly located was that 90% or more of all the images containing the structure had to be correctly identified. For 98% of the structures, the images identified by the automated algorithm agreed with those identified by the radiologist, and in 83% of cases, image contours showed a good in-plane overlap. The results of this validation study demonstrate that this combination of registration and natural language processing is accurate in identifying relevant images from brain MR imaging studies. However, the range of applicability of this technique has yet to be determined by applying the technique to a large number of studies.

Algorithms↗