Fluorescence spectroscopy for identification of atherosclerotic tissue.

OBJECTIVE: Vessel perforation and limited steerability of the laser light are the major limitations of laser angioplasty. To improve steerability fluorescence spectroscopy has been proposed for identification of atherosclerotic plaques. The aim was to investigate this. METHODS: Fluorescence spectroscopy with three different excitation wavelengths (325 nm, 380 nm, 450 nm) was tested in an emission range of 400 nm to 600 nm. Intensity ratios at 480/420 nm were determined in different types of blood vessels. Necropsy material from 40 patients (punch biopsies of 4 mm diameter from the coronary and carotid artery as well as from the ascending and descending aorta) was studied spectroscopically. Histological alterations of the vessel wall were assessed by a semiquantitative score (0 to 10 points): (a) normal tissue, 0 to 2 points (mean = 0.25; n = 38); (b) mild atherosclerotic lesions, 3 to 5 points (mean = 3.35; n = 39); (c) severe atherosclerotic lesions, greater than or equal to 6 points (mean = 6.75; n = 43). RESULTS: Best spectroscopic results were obtained with an excitation wavelength of 325 nm. In samples with severe atherosclerotic lesions the fluorescence spectra showed a significant reduction of the emitted wavelength intensities when compared to normal tissue. There was a clear separation of the fluorescence spectra between normal and mild as well as between normal and severe atherosclerotic lesions; normal tissue showed an increased intensity in the range from 420 nm to 540 nm, whereas atherosclerotic lesions had no or only a small peak at 480 nm. There was a significant correlation between the semiquantitative score (n = 120) and the fluorescence ratio at 480/420 nm (excitation wavelength 325 nm) with a correlation coefficient of 0.87. The spectroscopic results showed no differences between the samples taken from different types of vessels. CONCLUSIONS: Fluorescence spectroscopy allows a reliable identification of normal and atherosclerotic lesions. The close correlation between the emitted light intensity ratio at 480/420 nm and the histological alterations of the vessel wall suggests a relationship between vessel wall fluorescence and the atherosclerotic alterations of the wall.

Adolescent

Wearable digital speech processor for cochlear implants using a TMS320C25.

Based on a single-chip DSP (TMS320C25, Texas Instruments) a programmable battery-operated sound processor with a digital encoder interface for the Nucleus-22 cochlear implant (CI) was built. The number of quasi-simultaneously addressed electrodes is only limited by the selected pulse width and the maximum rate of stimulation and can be as high as 10 electrodes at 300 Hz repetition rate. Implementation of various processing strategies (formant or channel vocoder, filterbank, zero crossings, etc.) is possible as well as sophisticated adaptive noise reduction. Programs and stimulation parameters are stored in electrically erasable memory and may be updated via a host computer. The built-in analog output may be used for single-channel stimulation or acoustic verifications of the sound processing algorithms. The power consumption with current 16K word data memory and at maximum stimulation rate is about 1 Watt, which necessitates recharging of batteries after 11 h.

Cochlear Implants