PubMed Health⌕ Search

Biomedical subjects

U Wild

Publications and source records attributed to U Wild.

18 recordsLinked to original sources

Diesel engine exhaust emission: oxidative behavior and microstructure of black smoke soot particulate.

Soot particulate collected from a Euro III heavy duty diesel engine run under black smoke conditions was investigated using thermogravimetry, transmission electron microscopy, electron energy loss spectroscopy, and X-ray photoelectron spectroscopy. The characterization results are compared with those of commercial carbon black. The onset temperature toward oxidation of the diesel engine soot in 5% O2 is 150 degrees C lower than that for carbon black. The burn out temperature for the diesel engine soot is 60 degrees C lower than that of the carbon black. The soot primary particles exhibit a core-shell structure. The shell of the soot particles consists of homogeneously stacked basic structure units. The commercial carbon lamp black is more graphitized than the diesel engine soot, whereas the diesel engine soot contains more carbon in aromatic nature than the carbon black and is highly surface-functionalized. Our findings reveal that technical carbon black is not a suitable model for the chemistry of the diesel engine soot.

Air Pollutants↗

Surface state and composition of a disperse Pd catalyst after its exposure to ethylene.

Pd black was exposed to ethylene alone or in its mixture with hydrogen at 300 and 573 K. The samples were investigated by X-ray photoelectron spectroscopy (XPS) and ultraviolet photoelectron spectroscopy (UPS). Room temperature introduction of C(2)H(4) (also in the presence of H(2)) induced a binding-energy (BE) shift in the Pd 3d doublet and changed its full width at half-maximum (fwhm). The UPS features indicate shifting of electrons from the Pd d-band to Pd-H, Pd-C, and even Pd-OH species. Vinylidene (BE approximately 284.1 eV) may be the most abundant individual surface species on disperse Pd black, along with carbon in various stages of polymerization: "disordered C" (BE approximately 284 eV), graphite (approximately 284.6 eV), and ethylene polymer (approximately 286 eV), and also some "atomic" C (BE approximately 283.5 eV). Introduction of H(2) followed by ethylene brought about stronger changes in the state of Pd than exposure in the reverse sequence. This may indicate that the presence of some surface C may hinder the decomposition of bulk PdH. Formation of Pd hydride was blocked when ethylene was introduced prior to H(2). The C 1s intensity increased, the low-binding-energy C components disappeared, and graphitic carbon (BE approximately equal to 284.6 eV) prevailed after ethylene treatment at 573 K. The loss of the Pd surface state and "PdH" signal were observed in the corresponding valence band and UPS spectra. Hydrogen treatment at 540 K was not able to decrease the concentration of surface carbon and re-establish the near-surface H-rich state. UPS showed overlayer-type C in these samples. The interaction of Pd with components from the feed gas modified its electronic structure that is consistent with lattice strain induced by dissolution of carbon and hydrogen into Pd, as indicated by the d-band shift and the dilution of the electron density at E(F).

Journal Article↗

Analysis of the comparative workflow and performance characteristics of the VITEK 2 and Phoenix systems.

The VITEK 2 (bioMérieux, Marcy L'Etoile, France) and the Phoenix systems (BD Diagnostic Systems, Sparks, Md.) are automated instruments for rapid organism identification and susceptibility testing. We evaluated the workflow, the time to result, and the performance of identification and susceptibility testing of both instruments. A total of 307 fresh clinical isolates were tested: 141 Enterobacteriaceae, 22 nonfermenters, 93 Staphylococcus spp., and 51 Enterococcus spp. Manipulation time was measured in batches, each with seven isolates, for a total of 39 batches. The mean (+/- standard deviation [SD]) manipulation time per batch was 20.9 +/- 1.8 min for Phoenix and 10.6 +/- 1.0 min for VITEK 2 (P < 0.001). Mean (+/-SD) time to result for all bacterial groups was 727 +/- 162 min for Phoenix and 506 +/- 120 min for VITEK 2 (P < 0.001). Concerning identification, Phoenix and VITEK 2 yielded the same results for nonfermenters (100%), staphylococci (97%), and enterococci (100%). For 140 Enterobacteriaceae strains evaluated, 135 (96%) were correctly identified by Phoenix and 137 (98%) by VITEK 2 (P = 0.72). The overall category agreement for all isolates was 97.0% for both instruments. The minor error rate, major error rate, and very major error rate for all bacterial isolates tested were 3.0, 0.3, and 0.6 and 2.8, 0.2, and 1.7 for Phoenix and VITEK 2, respectively (P values of 0.76, 0.75, and 0.09). The VITEK 2 system required less manual manipulation time and less time than the Phoenix system to yield results.

Automation↗

Nitrogen and phosphorus budget in rewetted fens.

A former dewatered fen was flooded for a multi-purpose landuse system including cattail production, fen protection, and water purification. These research plants with an area of 6 ha consist of three constructed surface-flow wetlands. The inflowing water is polluted by non-point sources due to intensive agriculture. The focus of this paper is the estimation of the potential of rewetted fens to reduce phosphorus and nitrogen. The dominating forms of nitrogen in the inflow are organic nitrogen and nitrate. The reduction rate is higher for nitrate than for organic nitrogen, although the nitrate reductions occur only during the summer season. If no nitrate is available for denitrification, there is a release of ammonia from the peat into the water. The main form of phosphorus in the in- and outflow is ortho-phosphate. In contrast to the values of nitrate, the concentrations of phosphorus are very regular with no significant seasonal pattern. When nitrate isn't available in the water any more, the release of phosphorus begins and the rewetted fens change from a sink for phosphorus to a source of it. Rewetted fens can be a sink for phosphorus and nitrogen with nitrate as the limiting factor. Only if denitrification can occur, can the release of ammonia and phosphorus from the peat layer be prevented.

Ammonia↗

[Experimental autoimmune uveitis. Characterization of retina infiltrating cells].

UNLABELLED: The chronic model of murine EAU induced by interphotoreceptor retinoid binding protein represents a disease similar to clinical chorioretinitis. In this study we characterized the kinetics of retina infiltrating T-cells, macrophages and expression of the adhesion molecules ICAM-1 and ICAM-2. METHODS: B10.A mice were immunized subcutaneously with IRBP, and the eyes were analyzed on days 10, 18, 24 and 28. The infiltrating cells were characterized by mAbs recognizing T-cell receptors (TCR) Vss6 and Vss8, T-cell markers, macrophages and ICAM-1 and ICAM-2. RESULTS: While CD8+ T-cells and ICAM-2 were detectable from day 10 (retina is intact) until day 28, CD4+ T-cells, macrophages and ICAM-1 appear with the onset of retinal destruction. Starting at day 10 the dominating TCR was Vss6; Vss8 was noticed from day 18 on. CONCLUSION: CD8+ T-cells infiltrating the intact retina and stimulating the expression of high endothelial venules (HEVs) could be responsible for the onset of uveitis.

Acute Disease↗

Evidence from ultraviolet absorbance measurements for a codon-induced conformational change in lysine tRNA from Escherichia coli.

From experiments with equilibrium dialysis it was concluded earlier that formation of the codon-anticodon complex triggers a conformational change in the tertiary structure of tRNAPhe from Escherichia coli. A similar conformational transition is demonstrated here in the poly(A)/tRNALys system. C-G-A or C-G-A-A was used as a probe for the conformational transition in tRNA. These probes bound to tRNAPhe and tRNALys more strongly in the presence of the corresponding codons than in the absence. In order to verify these data by an independent method, the decrease in absorbance at 300 nm that occurs on formation of the codon-anticodon complex in tRNALys (which contains 2-thio-5-methylaminomethyluridine, s2mam5U) was used. The binding constants for formation of A3 . tRNALys (Ka = 2.4 . 10(4) M-1) and A4 . tRNALys (Ka = 2.5 . 10(5) M-1) are very close to those obtained by equilibrium dialysis. In the presence of C-G-A the apparent binding constant of A3 to tRNA was raised 10-fold to 2.5 . 10(-5) M-1. It was calculated that the constant for the binding of C-G-A to the binary complex A3 . tRNALys is approximately 2 . 10(4) M-1, whereas binding to the free tRNA is lower than 10(3) M-1. Under appropriate conditions binding of A3 to tRNALys can be induced directly by the addition of C-G-A. These data demonstrate that codon-anticodon complex formation induces a conformational change in the tRNA that as a consequence allows the binding of a trinucleoside diphosphate, presumably to the T-psi-G region.

Anticodon↗

[Influence of spontaneous collaterals on the fibrillation threshold of the heart following acute coronary occlusion].

Fibrillation threshold (FS) were determined in 27 mongrel dogs by direct electrical stimulation of the myocardium by 50 Hz AC impulses of 0.20-0.28 sec during the vulnerable period. The FS is the current which just suffices to produce ventricular fibrillation. Sinus rhythm was restored 10 sec after onset of ventricular fibrillation by defibrillation. Determinations of FS were carried out for each animal repeatedly before and 3 min after acute ligation of the circumflex ramus respectively the descendens ramus of the left coronary artery. Post mortem selective coronary angiography was performed in all cases and the extent of spontaneous collateral vessels was estimated by the rate of retrograde contrast radiography of the ligated coronary artery. The FS fell appreciably following acute ligation of both the circumflex ramus and the sescendens ramus. Beside the size of the ligated area (the circumflex ramus supplies a larger area of the myocardium in the dog than the ramus descendens) the extent of collateral supply was the determining factor for the reductions of the FS: Following coronary ligation of the circumflex ramus the FS fell on the average from 24.0 mA to 4.1 mA if no collateral vessels were detectable; in the animals with well developed collaterals the FS was reduced from 24.8 to only 14.1 mA. After acute occlusion of the descendens ramus the FS fell from 27.9 mA to 11.5 mA in the group with not sufficient collateral supply and from 31.2 mA to only 21.5 mA in the group with well developed collaterals. The comparison of the different decreases of the FS after coronary occlusion clearly shows that the influence of the in size differing ischemic areas on the decrease of the FS is particularly evident if no collateral vessels are existent. If collateral vessels are well developed this difference is not significant. These results demonstrate that the influence of well developed collaterals on the decrease of the FS after coronary occlusion exceeds the dependence on the size of the ischemic area.

Acute Disease↗