A lysine dehydrogenase-based electrode for biosensing of L-lysine.

An amperometric biosensor for L-lysine based on the recently isolated enzyme lysine dehydrogenase is described. Immobilization of the enzyme onto a platinum electrode is achieved via entrapment within a gelatin support on a cellulose membrane. Anodic detection (at 0.4 V vs. Ag/AgCl) is facilitated by the presence of a redox-mediating ferricyanide ion. The effect of experimental variables such as pH, enzyme loading, applied potential, cofactor and mediator concentrations were evaluated in order to optimize the analytical performance. A detection limit of 7 x 10(-8) M, and linearity up to 7 x 10(-4) M are reported. The fast response permits adaptation for flow injection operation with good precision (RSD = 1.9%) and high sample throughout (40 samples per hour). The high specificity offered by this new enzyme is indicated by the lack of interference by other L-amino acids, alcohols or carbohydrates.

Amino Acid Oxidoreductases

Enzyme sensor-FIA-system for on-line monitoring of glucose, lactate and glutamine in animal cell cultures.

Enzyme sensors for glucose, lactate and glutamine were connected via flow-injection analysis (FIA) devices to two different bioprocesses. They were used for on-line process control of perfused bioreactor systems containing mammalian cell lines producing a monoclonal antibody and recombinant interleukin-2. The biosensor system gives direct access to important process data which can be used as control parameters for long term cell cultivation systems.

Animals

Second generation biosensors.

Enzyme-membrane electrodes using glucose oxidase in combination with peroxide detection dominate in the field of laboratory analyzers for diluted samples. Using the same indication principle, extremely fast responding glucose sensors have been fabricated by covering thin metal electrodes with a porous enzyme layer. In the second generation auxiliary enzymes and/or co-reactants are coimmobilized with the analyte converting enzyme in order to improve the analytical quality and to simplify the performance. Following this line oxidizable interferences are suppressed by using a glucose oxidase/peroxidase complex which communicates with the electrode at a low working potential. Furthermore, fluctuations of pH or buffer capacity are ineffective when using a glucose oxidase/peroxidase layer covered fluoride FET in the potentiometric glucose determination. Enzymatic recycling of the analyte and/or accumulation of intermediates increase the sensitivity by several orders of magnitude. Inclusion of NAD bound to PEG in the glucose dehydrogenase layer allows a reagentless glucose measurement.

Biosensing Techniques

Enzyme electrodes and their application.

Starting from the state of the art, principles for improving the analytical characteristics of enzyme electrodes are discussed. Coupling of appropriate amperometric electrode processes with enzyme systems, e.g. urease or aminopeptidases, results in a simplification of operation. Optimal sample frequencies are realized on the basis of enzyme membranes, with both a small characteristic diffusion time and a high enzyme activity, applied in a well-designed sample-processing system. Coupled enzyme reactions of the sequence or competition type are successfully used for extension to new analytes, e.g. inhibitors, cofactors or alternative substrates. Cyclization of the analyte enhances the sensitivity of enzyme electrodes to the nanomolar concentration range. Enzymic anti-interference layers are a tool for improving the sensor specificity. The operational characteristics of enzyme electrodes are thus adaptable to any given analytical problem.

Biotechnology