Quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPECT: validation of an elastic surface model approach in comparison to cardiac magnetic resonance imaging, 4D-MSPECT and QGS.

PURPOSE: The segmentation algorithm ESM based on an elastic surface model was validated for the assessment of left ventricular volumes and ejection fraction from ECG-gated myocardial perfusion SPECT. Additionally, it was compared with the commercially available quantification packages 4D-MSPECT and QGS. Cardiac MRI was used as the reference method. METHODS: SPECT and MRI were performed on 70 consecutive patients with suspected or proven coronary artery disease. End-diastolic (EDV) and end-systolic (ESV) volumes and left ventricular ejection fraction (LVEF) were derived from SPECT studies by using the segmentation algorithms ESM, 4D-MSPECT and QGS and from cardiac MRI. RESULTS: ESM-derived values for EDV and ESV correlated well with those from cardiac MRI (correlation coefficients R=0.90 and R=0.95, respectively), as did the measurements for LVEF (R=0.86). Both EDV and ESV were slightly overestimated for larger ventricles but not for smaller ventricles; LVEF was slightly overestimated irrespective of ventricle size. The above correlation coefficients are comparable to those for the 4D-MSPECT and QGS segmentation algorithms. However, results obtained with the three segmentation algorithms are not interchangeable. CONCLUSION: The ESM algorithm can be used to assess EDV, ESV and LVEF from gated perfusion SPECT images. Overall, the performance was similar to that of 4D-MSPECT and QGS when compared with cardiac MRI. Results obtained with the three tested segmentation methods are not interchangeable, so that the same algorithm should be used for follow-up studies and control subjects.

Adult↗

Strain rate analysis allows detection of differences in diastolic function between viable and nonviable myocardial segments.

Analysis of diastolic function for assessment of myocardial viability has not been evaluated. Strain rate (SR) analysis allows quantitative segmental analysis of myocardial function and has been used during dobutamine stimulation for assessment of systolic functional reserve. In 37 patients with ischemic left ventricular dysfunction diastolic function was evaluated at rest and during low-dose dobutamine stimulation (10 mug/kg/min) using SR imaging and related to F18-fluorodeoxyglucose positron emission tomography. Analysis of peak early (E waves) and late (A waves) diastolic myocardial SR was performed using apical views. In all, 317 segments had normal function at rest by 2-dimensional echocardiography. A total of 192 segments with dyssynergy at rest were classified by positron emission tomography as viable in 94 cases and nonviable in 98 cases. Dys-synergic segments had lower E and A waves SR compared with normal contracting segments. There were no significant differences in peak E and A waves SR at rest between dys-synergic viable and nonviable segments. With dobutamine stimulation peak E waves SR increased significantly for viable segments (0.89 +/- 0.51-1.06 +/- 0.51 L/s, P < .01) whereas it was unchanged for nonviable segments (0.77 +/- 0.49-0.78 +/- 0.48 L/s, P = .835). Peak A waves SR increased for viable (0.71 +/- 0.55-1.00 +/- 0.56 L/s, P < .01) and nonviable (0.57 +/- 0.47-0.71 +/- 0.58 L/s, P = .023) segments. However, during dobutamine stimulation peak A waves SR was larger ( P < .001) for viable than for nonviable segments. In conclusion, normal contracting segments at rest have higher E and A waves SR compared with dys-synergic segments. Dys-synergic viable myocardial segments demonstrate an increase in E and A waves SR with dobutamine stimulation whereas nonviable segments are less responsive to dobutamine.

Analysis of Variance↗

Use of fractional flow reserve versus stress perfusion scintigraphy in stent restenosis.

BACKGROUND: Fractional flow reserve (FFR) is a valid surrogate for hemodynamic significance in stenotic native coronary arteries. The aim of this study was to examine the value of FFR compared to stress perfusion myocardial scintigraphy (SPMS) in patients with coronary stent restenosis. METHODS: We studied 42 patients, aged 62+/-10 years, with stent restenosis 5.3+/-1.6 months after coronary stent implantation. All patients had a single coronary lesion of intermediate severity (diameter stenosis 40-70%). FFR measurement, SPMS, and quantitative angiography of the stent stenosis were performed in all patients. RESULTS: The mean percentage in stent diameter stenosis was 53+/-9%. FFR was 0.77+/-0.15. In 20 patients FFR was below 0.75. Nineteen patients had reversible perfusion defects in SPMS. FFR showed good diagnostic accuracy for the detection of reversible perfusion defects in SPMS (AUROC 0.86, 95% CI 0.74-0.98). The percentage of agreement of SPMS and FFR was 88%, with the best cutoff value of 0.75 for FFR. CONCLUSIONS: A FFR value of 0.75 is not only valid for diagnosing significant native coronary stenosis, but also for stent restenosis. Thus, FFR measurement should be taken into account when making decisions regarding patients with stent restenosis.

Journal Article↗

Quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPECT: MRI validation and comparison of the Emory Cardiac Tool Box with QGS and 4D-MSPECT.

UNLABELLED: The goal of this study was to validate the accuracy of the Emory Cardiac Tool Box (ECTB) in assessing left ventricular end-diastolic or end-systolic volume (EDV, ESV) and ejection fraction (LVEF) from gated (99m)Tc-methoxyisobutylisonitrile ((99m)Tc-MIBI) SPECT using cardiac MRI (cMRI) as a reference. Furthermore, software-specific characteristics of ECTB were analyzed in comparison with 4D-MSPECT and Quantitative Gated SPECT (QGS) results (all relative to cMRI). METHODS: Seventy patients with suspected or known coronary artery disease were examined using gated (99m)Tc-MIBI SPECT (8 gates/cardiac cycle) 60 min after tracer injection at rest. EDV, ESV, and LVEF were calculated from gated (99m)Tc-MIBI SPECT using ECTB, 4D-MSPECT, and QGS. Directly before or after gated SPECT, cMRI (20 gates/cardiac cycle) was performed as a reference. EDV, ESV, and LVEF were calculated using Simpson's rule. RESULTS: Correlation between results of gated (99m)Tc-MIBI SPECT and cMRI was high for EDV (R = 0.90 [ECTB], R = 0.88 [4D-MSPECT], R = 0.92 [QGS]), ESV (R = 0.94 [ECTB], R = 0.96 [4D-MSPECT], R = 0.96 [QGS]), and LVEF (R = 0.85 [ECTB], R = 0.87 [4D-MSPECT], R = 0.89 [QGS]). EDV (ECTB) did not differ significantly from cMRI, whereas 4D-MSPECT and QGS underestimated EDV significantly compared with cMRI (mean +/- SD: 131 +/- 43 mL [ECTB], 127 +/- 42 mL [4D-MSPECT], 120 +/- 38 mL [QGS], 137 +/- 36 mL [cMRI]). For ESV, only ECTB yielded values that were significantly lower than cMRI. For LVEF, ECTB and 4D-MSPECT values did not differ significantly from cMRI, whereas QGS values were significantly lower than cMRI (mean +/- SD: 62.7% +/- 13.7% [ECTB], 59.0% +/- 12.7% [4DM-SPECT], 53.2% +/- 11.5% [QGS], 60.6% +/- 13.9% [cMRI]). CONCLUSION: EDV, ESV, and LVEF as determined by ECTB, 4D-MSPECT, and QGS from gated (99m)Tc-MIBI SPECT agree over a wide range of clinically relevant values with cMRI. Nevertheless, any algorithm-inherent over- or underestimation of volumes and LVEF should be accounted for and an interchangeable use of different software packages should be avoided.

Adult↗

FDG PET and tumour markers in the diagnosis of recurrent and metastatic breast cancer.

Breast cancer continues to be one of the most common cancers in North America and Western Europe. Positron emission tomography with 2-[fluorine-18]-fluoro-2-deoxy-D-glucose (FDG PET) represents a non-invasive functional imaging modality that is based on metabolic characteristics of malignant tumours. In breast cancer, FDG PET is more accurate than conventional methods for staging of distant metastases or local recurrences and enables early assessment of treatment response in patients undergoing primary chemotherapy. Recent data indicate a rationale for the use of FDG PET in cases of asymptomatically elevated tumour marker levels in the presence of uncertain results of conventional imaging. Despite the fact that PET cannot rule out microscopic disease, it does have particular value in providing, in a single examination, a reliable assessment of the true extent of the disease. This technique is complementary to morphological imaging for primary diagnosis, staging and re-staging. It may become the method of choice for the assessment of asymptomatic patients with elevated tumour marker levels. This method, however, cannot replace invasive procedures if microscopic disease is of clinical relevance.

Biomarkers, Tumor↗

Validation of 4D-MSPECT and QGS for quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPET: comparison with cardiac magnetic resonance imaging.

The main aim of this study was to validate the accuracy of 4D-MSPECT in the assessment of left ventricular (LV) end-diastolic/end-systolic volumes (EDV, ESV) and ejection fraction (LVEF) from gated technetium-99m methoxyisobutylisonitrile single-photon emission tomography ((99m)Tc-MIBI SPET), using cardiac magnetic resonance imaging (cMRI) as the reference method. By further comparing 4D-MSPECT and QGS with cMRI, the software-specific characteristics were analysed to elucidate clinical applicability. Fifty-four patients with suspected or proven coronary artery disease (CAD) were examined with gated (99m)Tc-MIBI SPET (8 gates/cardiac cycle) about 60 min after tracer injection at rest. LV EDV, ESV and LVEF were calculated from gated (99m)Tc-MIBI SPET using 4D-MSPECT and QGS. On the same day, cMRI (20 gates/cardiac cycle) was performed, with LV EDV, ESV and LVEF calculated using Simpson's rule. Both algorithms worked with all data sets. Correlation between the results of gated (99m)Tc-MIBI SPET and cMRI was high for EDV [ R=0.89 (4D-MSPECT), R=0.92 (QGS)], ESV [ R=0.96 (4D-MSPECT), R=0.96 (QGS)] and LVEF [ R=0.89 (4D-MSPECT), R=0.90 (QGS)]. In contrast to ESV, EDV was significantly underestimated by 4D-MSPECT and QGS compared to cMRI [130+/-45 ml (4D-MSPECT), 122+/-41 ml (QGS), 139+/-36 ml (cMRI)]. For LVEF, 4D-MSPECT and cMRI revealed no significant differences, whereas QGS yielded significantly lower values than cMRI [57.5%+/-13.7% (4D-MSPECT), 52.2%+/-12.4% (QGS), 60.0%+/-15.8% (cMRI)]. In conclusion, agreement between gated (99m)Tc-MIBI SPET and cMRI is good across a wide range of clinically relevant LV volume and LVEF values assessed by 4D-MSPECT and QGS. However, algorithm-varying underestimation of LVEF should be accounted for in the clinical context and limits interchangeable use of software.

Adult↗

Preoperative mapping of cortical motor function: prospective comparison of functional magnetic resonance imaging and [15O]-H2O-positron emission tomography in the same co-ordinate system.

BACKGROUND: Two of the most widely accepted approaches to map eloquent cortical areas preoperatively are positron emission tomography (PET) and functional magnetic resonance imaging (fMRI). As yet, no study has compared these two modalities within the same frame of reference in tumour patients. AIM: We employed [15O]-H2O-PET and fMRI in patients undergoing presurgical evaluation and compared the results with those obtained by direct electrical cortical stimulation (DECS). METHODS: Twenty-five patients with tumours of different aetiology near the central region were investigated. fMRI and PET were processed using the same methods, i.e. statistical parametric mapping (SPM) without anatomical normalization, and transformed into the same frame of reference. RESULTS: fMRI activity was found in more cranial and lateral sections, i.e. closer to the brain surface, in comparison with PET, which demonstrated parenchymal activation. The mean localization difference between fMRI and PET was 8.1 +/- 4.6 mm (range, 2-18 mm). fMRI and [15O]-H2O-PET could reliably identify the central sulcus, as demonstrated by DECS. CONCLUSIONS: fMRI and [15O]-H2O-PET demonstrate comparable results and are sensitive and reliable tools to map the central region, especially in cases of infiltrating brain tumours. However, fMRI is more prone to artefacts, such as the visualization of draining veins, which may explain the more cranial and lateral activation visualized by fMRI, whereas PET depicts capillary perfusion changes and therefore shows activation closer to the parenchyma.

Adult↗

Validation of QGS and 4D-MSPECT for quantification of left ventricular volumes and ejection fraction from gated 18F-FDG PET: comparison with cardiac MRI.

UNLABELLED: The aim of this study was to validate Quantitative Gated SPECT (QGS) and 4D-MSPECT for assessing left ventricular end-diastolic and systolic volumes (EDV and ESV, respectively) and left ventricular ejection fraction (LVEF) from gated (18)F-FDG PET. METHODS: Forty-four patients with severe coronary artery disease were examined with gated (18)F-FDG PET (8 gates per cardiac cycle). EDV, ESV, and LVEF were calculated from gated (18)F-FDG PET using QGS and 4D-MSPECT. Within 2 d (median), cardiovascular cine MRI (cMRI) (20 gates per cardiac cycle) was done as a reference. RESULTS: QGS failed to accurately detect myocardial borders in 1 patient; 4D-MSPECT, in 2 patients. For the remaining 42 patients, correlation between the results of gated (18)F-FDG PET and cMRI was high for EDV (R = 0.94 for QGS and 0.94 for 4D-MSPECT), ESV (R = 0.95 for QGS and 0.95 for 4D-MSPECT), and LVEF (R = 0.94 for QGS and 0.90 for 4D-MSPECT). QGS significantly (P < 0.0001) underestimated LVEF, whereas no other parameter differed significantly between gated (18)F-FDG PET and cMRI for either algorithm. CONCLUSION: Despite small systematic differences that, among other aspects, limit interchangeability, agreement between gated (18)F-FDG PET and cMRI is good across a wide range of clinically relevant volumes and LVEF values assessed by QGS and 4D-MSPECT.

Aged↗

Prone versus supine patient positioning during gated 99mTc-sestamibi SPECT: effect on left ventricular volumes, ejection fraction, and heart rate.

UNLABELLED: Gated myocardial perfusion SPECT allows assessment of left ventricular end-diastolic volume (EDV), left ventricular end-systolic volume (ESV), left ventricular stroke volume (SV), and left ventricular ejection fraction (LVEF). Acquiring images with the patient both prone and supine is an approved method of identifying and reducing artifacts. Yet prone positioning alters physiologic conditions. This study investigated how prone versus supine patient positioning during gated SPECT affects EDV, ESV, SV, LVEF, and heart rate. METHODS: Forty-eight patients scheduled for routine myocardial perfusion imaging were examined with gated (99m)Tc-sestamibi SPECT (at rest) while positioned prone and supine (consecutively, in random order). All parameters for both acquisitions were calculated using the commercially available QGS algorithm. RESULTS: Whereas EDV and SV were significantly lower (P < 0.0004) for prone acquisitions (EDV, 110.5 +/- 39.1 mL; SV, 55.9 +/- 13.3 mL) than for supine acquisitions (EDV, 116.9 +/- 36.2 mL; SV, 61.0 +/- 14.5 mL), ESV and LVEF did not differ significantly. Heart rate was significantly higher (P < 0.0001) during prone acquisitions (69.1 +/- 10.5 min(-1)) than during supine acquisitions (66.5 +/- 10.0 min(-1)). CONCLUSION: The observed position-dependent effect on EDV, SV, and heart rate might be explained by decreased arterial filling and increased sympathetic nerve activity. Hence, supine reference data should not be used to classify the results of prone acquisitions.

Adult↗

Preoperative mapping of cortical language areas in adult brain tumour patients using PET and individual non-normalised SPM analyses.

In patients scheduled for the resection of perisylvian brain tumours, knowledge of the cortical topography of language functions is crucial in order to avoid neurological deficits. We investigated the applicability of statistical parametric mapping (SPM) without stereotactic normalisation for individual preoperative language function brain mapping using positron emission tomography (PET). Seven right-handed adult patients with left-sided brain tumours (six frontal and one temporal) underwent 12 oxygen-15 labelled water PET scans during overt verb generation and rest. Individual activation maps were calculated for P<0.005 and P<0.001 without anatomical normalisation and overlaid onto the individuals' magnetic resonance images for preoperative planning. Activations corresponding to Broca's and Wernicke's areas were found in five and six cases, respectively, for P<0.005 and in three and six cases, respectively, for P<0.001. One patient with a glioma located in the classical Broca's area without aphasic symptoms presented an activation of the adjacent inferior frontal cortex and of a right-sided area homologous to Broca's area. Four additional patients with left frontal tumours also presented activations of the right-sided Broca's homologue; two of these showed aphasic symptoms and two only a weak or no activation of Broca's area. Other frequently observed activations included bilaterally the superior temporal gyri, prefrontal cortices, anterior insulae, motor areas and the cerebellum. The middle and inferior temporal gyri were activated predominantly on the left. An SPM group analysis ( P<0.05, corrected) in patients with left frontal tumours confirmed the activation pattern shown by the individual analyses. We conclude that SPM analyses without stereotactic normalisation offer a promising alternative for analysing individual preoperative language function brain mapping studies. The observed right frontal activations agree with proposed reorganisation processes, but they may also reflect an unspecific recruitment of the right-sided Broca's homologue in the effort to perform the task.

Adult↗

Cardiac resynchronization therapy homogenizes myocardial glucose metabolism and perfusion in dilated cardiomyopathy and left bundle branch block.

OBJECTIVES: We investigated whether cardiac resynchronization therapy (CRT) affects myocardial glucose metabolism and perfusion in dilated cardiomyopathy (DCM) and left bundle branch block (LBBB). BACKGROUND: Patients with DCM and LBBB present with asynchronous left ventricular (LV) activation, leading to reduced septal glucose metabolism. Cardiac resynchronization therapy recoordinates LV activation, but its effects on myocardial glucose metabolism and perfusion remain unknown. METHODS: In 15 patients (10 females; 61 +/- 13 years) with DCM and LBBB (QRS width 165 +/- 15 ms), gated (18)F-fluorodeoxyglucose (FDG) positron emission tomography (PET) and technetium-99m ((99m)Tc)-sestamibi single-photon emission computed tomography were performed before and after two weeks of CRT. Uptake of FDG and (99m)Tc-sestamibi was determined in four LV wall areas. Ejection fraction and volumes were calculated from gated PET. RESULTS: Baseline FDG uptake was heterogeneous (p < 0.0001), with lowest uptake in the septal region (56 +/- 12%) and highest uptake in the lateral region (89 +/- 6%). During CRT, septal and anterior increases (p < 0.01) and lateral decreases (p < 0.01) resulted in homogeneously distributed glucose metabolism. Baseline heterogeneity (p < 0.0001) in (99m)Tc-sestamibi uptake was modest (lowest septal 65 +/- 10%; maximum lateral 84 +/- 5%) and also reduced with CRT, although some heterogeneity (p < 0.05) remained. The septal-to-lateral ratio increased with CRT for FDG (0.62 +/- 0.12 to 0.91 +/- 0.26, p < 0.001) and (99m)Tc-sestamibi uptake (0.77 +/- 0.13 to 0.85 +/- 0.16, p < 0.01). The LV end-diastolic and end-systolic volumes decreased from 293 +/- 160 to 272 +/- 158 ml (p < 0.05) and from 244 +/- 164 to 220 +/- 160 ml (p < 0.01), respectively. Ejection fraction increased from 22 +/- 12% to 25 +/- 13% (p < 0.01). CONCLUSIONS: Glucose metabolism is reduced more than perfusion in the septal compared with LV lateral wall in patients with DCM and LBBB. Cardiac resynchronization therapy restores homogeneous myocardial glucose metabolism with less influence on perfusion.

Aged↗

Validation of an evaluation routine for left ventricular volumes, ejection fraction and wall motion from gated cardiac FDG PET: a comparison with cardiac magnetic resonance imaging.

The aim of this study was to validate the estimation of left ventricular end-diastolic and end-systolic volumes (EDV, ESV) and ejection fraction (LVEF) as well as wall motion analysis from gated fluorine-18 fluorodeoxyglucose (FDG) positron emission tomography (PET) in patients with severe coronary artery disease (CAD) using software originally designed for gated single-photon emission tomography (SPET). Thirty patients with severe CAD referred for myocardial viability diagnostics were investigated using a standard FDG PET protocol enhanced with gated acquisition (8 gates per cardiac cycle). EDV, ESV and LVEF were calculated using standard software designed for gated SPET (QGS). Wall motion was analysed using a visual four-point wall motion score on a 17-segment model. As a reference, all patients were also examined within a median of 3 days with cardiovascular cine magnetic resonance imaging (cMRI) (20 gates per cardiac cycle). Furthermore, all gated FDG PET data sets were reoriented in a second run with deliberately misaligned axes to test the quantification procedure for robustness. Correlation between the results of gated FDG PET and cMRI was very high for EDV and ESV ( R=0.96 and R=0.97) and for LVEF ( R=0.95). With gated FDG PET, there was a non-significant tendency to underestimate EDV (174+/-61 ml vs 179+/-59 ml, P=0.21) and to overestimate ESV (124+/-58 ml vs 122+/-60 ml, P=0.65), resulting in underestimated LVEF values (31.5%+/-9.4% vs 34.2%+/-12.4%, P<0.003). The results of reorientations 1 and 2 showed very high correlations (for all R>/=0.99). Segmental wall motion analysis revealed good agreement between gated FDG PET data and cMRI (kappa =0.62+/-0.03). In conclusion, despite small systematic differences which contributed mainly to the lower temporal resolution of gated FDG PET, agreement between gated FDG PET and cMRI was good across a wide range of volumes and LVEF values as well as for wall motion analysis. Therefore, gated FDG PET provides clinically relevant information on function and volumes, using the commercially available software package QGS.

Aged↗

Comparison of microsphere-equivalent blood flow (15O-water PET) and relative perfusion (99mTc-tetrofosmin SPECT) in myocardium showing metabolism-perfusion mismatch.

UNLABELLED: Myocardial perfusion imaging with (99m)Tc-tetrofosmin is based on the assumption of a linear correlation between myocardial blood flow (MBF) and tracer uptake. However, it is known that (99m)Tc-tetrofosmin uptake is directly related to energy-dependent transport processes, such as Na(+)/H(+) ion channel activity, as well as cellular and mitochondrial membrane potentials. Therefore, cellular alterations that affect these energy-dependent transport processes ought to influence (99m)Tc-tetrofosmin uptake independently of blood flow. Because metabolism ((18)F-FDG)-perfusion ((99m)Tc-tetrofosmin) mismatch myocardium (MPMM) reflects impaired but viable myocardium showing cellular alterations, MPMM was chosen to quantify the blood flow-independent effect of cellular alterations on (99m)Tc-tetrofosmin uptake. Therefore, we compared microsphere-equivalent MBF (MBF_micr; (15)O-water PET) and (99m)Tc-tetrofosmin uptake in MPMM and in "normal" myocardium. METHODS: Forty-two patients with severe coronary artery disease, referred for myocardial viability diagnostics, were examined using (18)F-FDG PET and (99m)Tc-tetrofosmin perfusion SPECT. Relative (18)F-FDG and (99m)Tc-tetrofosmin uptake values were calculated using 18 segments per patient. Normal myocardium and MPMM myocardium were classified using a previously validated (99m)Tc-tetrofosmin SPECT/(18)F-FDG PET score. In addition, (15)O-water PET was performed to assess kinetic-modeled MBF (MBF_kin), the water-perfusable tissue fraction (PTF), and the resulting MBF_micr (MBF_kin x PTF), which is comparable to tracer uptake values. (99m)Tc-tetrofosmin uptake and MBF_micr values were calculated for all normal and MPMM segments and averaged within their respective classifications. RESULTS: Mean relative (99m)Tc-tetrofosmin uptake was 86% +/- 1% in normal myocardium and 56% +/- 1% in MPMM, showing a significant difference (P < 0.001), as was expected from the classification. Contrary to these findings, mean MBF_micr in MPMM myocardium was 0.60 +/- 0.03 mL x min(-1) x mL(-1), which did not significantly differ from normal myocardium (0.64 +/- 0.01 mL x min(-1) x mL(-1)). All values are given as mean +/- SEM. CONCLUSION: Differences between reduced (99m)Tc-tetrofosmin uptake and the unchanged MBF_micr in MPMM myocardium suggest that the pathophysiologic basis of MPMM is not a blood flow reduction but cellular alterations that affect uptake and retention of (99m)Tc-tetrofosmin independently of blood flow. Therefore, it seems that perfusion deficits in MPMM myocardium are greatly overestimated by (99m)Tc-tetrofosmin and that it tends to give false-positive findings.

Adult↗

Mediastinal staging of lung cancer with 2-[fluorine-18]-fluoro-2-deoxy-D-glucose positron emission tomography and a dual-head coincidence gamma camera.

The aims of the present study were (a) to evaluate mediastinal staging in patients with lung cancer with 2-[fluorine-18]-fluoro-2-deoxy-D-glucose (FDG) using a coincidence gamma camera (hybrid PET) in comparison with dedicated positron emission tomography (PET) and computed tomography (CT), and (b) to assess the feasibility to determine standardized uptake values (SUV) with hybrid PET. Forty patients were included in the study. Hybrid PET was performed without and with attenuation correction. Data were rebinned with single-slice (SSRB) or Fourier rebinning (FORE). The SUVs of primary tumors were calculated with hybrid PET and compared with SUVs determined by dedicated PET. Diagnostic accuracy for hybrid with or without attenuation correction was 80 or 74% compared with 82% for dedicated PET, and 63% for CT. Attenuation-corrected hybrid PET revealed a higher specificity than CT (83 vs 52%; p<0.05). The SUVs of primary tumors were similar to those of hybrid PET and dedicated PET with a mean relative difference of 20.8+/-16.4%. The FORE improved the agreement of SUVs with a mean relative difference of 13.8+/-9.9 vs 36.0+/-17.9% for SSRB ( p<0.001). Hybrid PET with attenuation correction is more specific than CT for mediastinal staging in patients with lung cancer ( p<0.05). It reveals similar results in comparison with dedicated PET. Calculation of SUVs with hybrid PET is feasible.

Adenocarcinoma↗