Images in cardiovascular medicine. Left main coronary artery compression syndrome: evaluation with 64-slice cardiac multidetector computed tomography.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to Udo Hoffmann.
Explore the source record for details and available documents.
Along with coronary evaluation, 64-slice multidetector computed tomography (MDCT) permits comprehensive assessment of left ventricular (LV) anatomy and function; however, how it compares with 2-dimensional transthoracic echocardiography (TTE) in patients with heart failure (HF) is not known. In this study, we compared 25 patients with ejection fractions of <45% who underwent TTE and MDCT. The global ejection fraction by TTE versus MDCT was 36 +/- 8% versus 38 +/- 12% (r = 0.67, p = NS). The mean LV end-diastolic and end-systolic diameters by TTE and MDCT were 56 +/- 8 and 46 +/- 9 mm and 58 +/- 12 and 47 +/- 11 mm, respectively (r = 0.71 and 0.77, respectively, both p >0.20). The mean lateral and septal wall thicknesses by TTE and MDCT were 10 +/- 1.4 and 11 +/- 1.5 mm and 10 +/- 1.3 and 10 +/- 1.4 mm (r = 0.77 and 0.76, respectively, both p >0.20). The mean LV end-diastolic and end-systolic volumes and stroke volume by TTE and MDCT were 123 +/- 45, 78 +/- 31, and 44 +/- 21 ml and 140 +/- 58, 92 +/- 43, and 48 +/- 24 ml, respectively (r = 0.62, 0.67, and 0.60, respectively, all p >0.20). The regional wall motion assessment correlation was good between the 2 modalities (kappa = 0.61). The interobserver correlation between the 2 MDCT readers ranged from good (r = 0.72 for LV end-diastolic volume) to excellent (r = 0.84 for septal wall thickness). In conclusion, MDCT provides comparable results to TTE for LV structure and functional assessment among patients with HF.
BACKGROUND: Noninvasive assessment of coronary atherosclerotic plaque and significant stenosis by coronary multidetector computed tomography (MDCT) may improve early and accurate triage of patients presenting with acute chest pain to the emergency department. METHODS AND RESULTS: We conducted a blinded, prospective study in patients presenting with acute chest pain to the emergency department between May and July 2005 who were admitted to the hospital to rule out acute coronary syndrome (ACS) with no ischemic ECG changes and negative initial biomarkers. Contrast-enhanced 64-slice MDCT coronary angiography was performed immediately before admission, and data sets were evaluated for the presence of coronary atherosclerotic plaque and significant coronary artery stenosis. All providers were blinded to MDCT results. An expert panel, blinded to the MDCT data, determined the presence or absence of ACS on the basis of all data accrued during the index hospitalization and 5-month follow-up. Among 103 consecutive patients (40% female; mean age, 54+/-12 years), 14 patients had ACS. Both the absence of significant coronary artery stenosis (73 of 103 patients) and nonsignificant coronary atherosclerotic plaque (41 of 103 patients) accurately predicted the absence of ACS (negative predictive values, 100%). Multivariate logistic regression analyses demonstrated that adding the extent of plaque significantly improved the initial models containing only traditional risk factors or clinical estimates of the probability of ACS (c statistic, 0.73 to 0.89 and 0.61 to 0.86, respectively). CONCLUSIONS: Noninvasive assessment of coronary artery disease by MDCT has good performance characteristics for ruling out ACS in subjects presenting with possible myocardial ischemia to the emergency department and may be useful for improving early triage.
OBJECTIVE: Atherosclerotic coronary artery calcification (CAC) is associated with increased coronary heart disease (CHD) risk. Matrix Gla protein (MGP) is an inhibitor of calcification in vivo. However, little is known regarding the distribution of circulating MGP and its associations with CHD risk factors or with CAC in humans. METHODS AND RESULTS: Serum MGP concentrations were determined in 2 independent populations of men and women free of clinically apparent cardiovascular disease: study A, n=316, mean age 58 years, and study B, n=452, mean age 68 years. CAC was determined by computed tomography. Mean MGP concentrations were 98.4 and 198 ng/mL in men, and 97.4 and 201 ng/mL in women, in study A and study B, respectively. In both cohorts, MGP levels were higher with increasing age. In age-adjusted analyses, there was an association of circulating MGP with increasing Framingham CHD risk score (in study A, P=0.003 in men and P=0.016 in women, respectively; in study B, a nonsignificant increase in men and P=0.05 in women, respectively). Significant associations of circulating MGP with high-density lipoprotein and other individual CHD risk factors were also noted in both cohorts. There were no consistent associations between MGP and CAC after adjustment for CHD risk score in the 2 cohorts. CONCLUSIONS: MGP is associated with individual CHD risk factors and the Framingham CHD risk score in men and women free of clinically apparent CHD. The relation of MGP with CAC deserves further study in larger populations.
Coronary computed tomographic angiography (CTA) accurately excludes the presence of coronary stenoses in selected patient populations. However, it remains unclear whether coronary CTA has the potential to replace invasive coronary angiography as a tool to assess a patient's suitability for revascularization as determined by the characterization of lesion morphology in patients with significant coronary artery disease. Coronary CTA (64-slice computed tomography) was performed before invasive coronary angiography in 29 patients. We evaluated the accuracy of CTA for the detection of complex lesion morphology, including the presence of severe calcium, total occlusions, and ostial or bifurcation location, and compared the results with those of invasive angiography. On CTA, 10 of 69 lesions (15%) were not evaluable for any feature of complex lesion morphology. Of the evaluable lesions, CTA detected >or=1 feature of complexity in 58% of lesions, corresponding to a sensitivity of 88% (23 of 26) and a specificity of 83% (24 of 29). For those single features, the sensitivity of CTA was 100% for the presence of severe calcium, 93% for total occlusions, and 60% and 80% for the detection of ostial and bifurcation lesions, respectively. The specificity was high for total occlusions (97%), ostial lesions (97%), and bifurcations (100%). It was moderate (85%) for severe calcium. Severe calcium precluded the evaluation of other features of complex lesion morphology in 6 lesions (11%). In conclusion, invasive selective coronary angiography remains the cornerstone to assess a patient's suitability for revascularization given the high proportion of unevaluable segments and segments with severe calcium that precluded adequate revascularization planning on CTA.
Coronary allograft vasculopathy (CAV) is the most important limitation to long-term survival in adult heart transplant recipients and is difficult to detect without intravascular ultrasound (IVUS). We systematically evaluated the image quality of 64-slice multidetector computed tomographic (MDCT) coronary angiography in heart transplant recipients and tested the hypothesis that this modality is comparable to invasive coronary angiography with IVUS for the detection of CAV. Heart transplant recipients (n = 20) underwent invasive coronary angiography with IVUS and MDCT coronary angiography with a 64-slice scanner. Images were systematically analyzed for image quality and the presence of CAV. In addition, multidetector computed tomography and quantitative coronary angiography were used to measure lumen diameters at prespecified locations. Image quality analysis showed that, despite high mean heart rates (77 +/- 7 beats/min) and body mass index (29.5 +/- 5.3 kg/m(2)), 83% of coronary segments were graded as of excellent or good image quality. On average, 95 +/- 9% of the overall visualized length of the coronary arteries was imaged without motion artifacts, and the mean contrast-to-noise ratio was 11.3 +/- 4.6. Compared with IVUS, multidetector computed tomography had a sensitivity of 70%, specificity of 92%, positive predictive value of 89%, and negative predictive value of 77% for the detection of CAV. MDCT vessel diameter measurements correlated well with those obtained from quantitative coronary angiography (R(2) = 0.89). In conclusion, 64-slice multidetector computed tomography provides good to excellent image quality in heart transplant recipients and has moderate to excellent test characteristics for the detection of CAV. Further, MDCT measurements of lumen diameters correlated well with quantitative coronary angiography.
PURPOSE: To evaluate the diagnostic performance of 16-section multidetector computed tomography (CT) for assessment of plaques in phantoms and ex vivo coronary arteries, with intravascular ultrasonography (US) and optical coherence tomography (OCT) as reference standards. MATERIALS AND METHODS: Research protocol was HIPAA compliant and approved by institutional review board, without informed consent required. Blood vessel and lesion composition phantoms and ex vivo coronary arteries were imaged with 16-section CT. Wall areas of phantoms and ex vivo coronary arteries were measured with multidetector CT and intravascular US. Sensitivity and specificity for lipid detection were determined in lesion composition phantoms. CT numbers of blood vessel wall were determined in ex vivo coronary arteries and compared with lesion classification results from OCT. Agreement in dimensional measurements was compared (paired t tests). CT numbers within blood vessel wall of CT cross sections classified as lipid rich, fibrous, and calcified at OCT were compared (Kruskal-Wallis tests). RESULTS: Mean blood vessel wall areas measured with CT and US in phantoms were 9.2 mm(2) +/- 1.8 (standard deviation) and 10.4 mm(2) +/- 3.4 (bias, -1.3 mm(2) +/- 3.1; P < .05), respectively. Mean blood vessel wall areas measured in ex vivo coronary arteries with CT and US were 10.9 mm(2) +/- 4.1 and 9.1 mm(2) +/- 3.1 (bias, 1.8 mm(2) +/- 3.0; P < .001), respectively. Sensitivity and specificity of 93% and 92%, respectively, for identification of lipid-rich lesions were observed in lesion composition phantoms. Mean CT numbers in blood vessel wall of ex vivo coronary arteries identified at OCT as predominantly lipid rich, fibrous, and calcified were 29 HU +/- 43, 101 HU +/- 21, and 135 HU +/- 199, respectively (P < .001). CONCLUSION: Determination of composition of individual plaques from attenuation values can be more challenging because of overlapping values for different tissue types.
Clinical use of cardiac computed tomography is rapidly expanding, and its purpose may reach beyond noninvasive coronary angiography. We investigated the ability of 64-slice multidetector computed tomography to differentiate between recent and long-standing myocardial infarction (MI). Contrast-enhanced coronary computed tomographic (CT) scans (Siemens Sensation 64) of patients with a recent MI (< 7 days, n = 16), long-standing MI (> 12 months, n = 13), and no MI (n = 13) were retrospectively evaluated. To anticipate transmural variation of myocardial perfusion and to neutralize image noise, a series of thin, overlapping slices was created in parallel alignment to the myocardial wall. Within each of these slices, a small region of interest was placed at a constant in-plane position to measure the CT attenuation (Hounsfield units [HU]) at consecutive transmural locations of injured and normal remote myocardium. In addition, wall thickness and the myocardial cavity were measured. Significantly lower CT attenuation values were found in patients with long-standing MI (-13 +/- 37 HU) than in those with acute MI (26 +/- 26 HU) and normal controls (73 +/- 14 HU, p < 0.001). The attenuation difference between infarcted and remote myocardia was larger in patients with long-standing MI than in patients with recent MI (89 +/- 41 and 55 +/- 33 HU, respectively, p < 0.001). In addition, long-standing MI was associated with wall thinning (p < 0.01), and ventricular dilation (p < 0.05), whereas recent MI was not (p > 0.05). In conclusion, recent and long-standing MIs may be differentiated by computed tomography based on myocardial CT attenuation values and ventricular dimensions.
Explore the source record for details and available documents.
OBJECTIVES: The purpose of this study was to assess morphology and composition of culprit and stable coronary lesions by multidetector computed tomography (MDCT). BACKGROUND: Noninvasive identification of culprit lesions has the potential to improve noninvasive risk stratification in patients with acute chest pain. METHODS: Thirty-seven patients with acute coronary syndrome (ACS) or stable angina underwent coronary 16-slice MDCT and invasive selective angiography. In all significant coronary lesions two observers measured the degree of stenosis, plaque area at stenosis, and remodeling index and assessed plaque composition. Differences between culprit lesions in patients with ACS and stable lesions in patients with ACS or stable angina were determined. RESULTS: We analyzed 40 lesions with excellent image quality in 14 patients with ACS and 9 patients with stable angina. Culprit lesions in patients with ACS (n = 14) had significantly greater plaque area and a higher remodeling index than both stable lesions in patients with ACS (n = 13) and in patients with stable angina (n = 13) (17.5 +/- 5.9 mm2 vs. 9.1 +/- 4.8 mm2 vs. 13.5 +/- 10.7 mm2, p = 0.02; and 1.4 +/- 0.3 vs. 1.0 +/- 0.4 vs. 1.2 +/- 0.3, p = 0.04, respectively). The prevalence of non-calcified plaque was 100%, 62%, and 77%, respectively, and the prevalence of calcified plaque was 71%, 92%, and 85%, respectively, in culprit lesions in patients with ACS and in stable lesions in patients with ACS or stable angina. CONCLUSIONS: We introduce the concept of noninvasive detection and characterization of coronary atherosclerotic lesions in patients with ACS by MDCT. We identified differences in lesion morphology and plaque composition between culprit lesions in ACS and stable lesions in ACS or stable angina, consistent with previous intravascular ultrasound studies.
UNLABELLED: Multi-detector row Computed Tomography (MDCT) permits non-invasive visualization of the coronary arteries. The ability to visualize and, with limitations, to characterize non-calcified coronary atherosclerotic plaque has been described. We investigated the CT attenuation of non-calcified plaques as determined by 16-slice MDCT in comparison to intravascular ultrasound (IVUS). METHODS AND RESULTS: Thirty-two patients were investigated by contrast-enhanced 16-slice CT. In addition, IVUS of one coronary artery (motorized pullback) was performed (LM+LAD: 22, LM+LCX: 4, RCA: 6). At 252 sites within the coronary system, in which non-calcified atherosclerotic plaque could be identified both in MDCT and IVUS, the CT attenuation within the plaque was measured using a centrally placed region of interest and correlated to the appearance of the plaque in IVUS at the corresponding location. The mean CT attenuation within plaque that corresponded to hyper-echogenic appearance in IVUS was 121+/-34HU (n=76). The mean CT attenuation within plaque that corresponded to hypo-echogenic appearance was 58+/-43HU (n=176, p<0.001). However, there was substantial overlap of the density values measured by MDCT in the two groups. CONCLUSIONS: A significant difference of the mean CT attenuation within atherosclerotic lesions of hypo-echogenic and hyper-echogenic appearance in IVUS could be observed. However, we observed substantial overlap of attenuation values between plaque types so that the differentiation of "vulnerable" and "stable" plaques based on their CT attenuation is doubtful.
We describe the case of a 72-year-old man presenting with endocarditis and clinical signs of acute myocardial ischemia after biological aortic valve replacement. A comprehensive cardiac dynamic multislice spiral computed tomography demonstrated: (1) an endocarditic vegetation of the aortic valve; (2) a subvalvular leakage feeding a paravalvular pseudoaneurysm based on an aortic root abscess with subsequent compromise of the systolic blood flow in the left main coronary artery and the resulting myocardial perfusion deficit.
BACKGROUND: Sixteen-slice multi-detector computed tomography (MDCT) permits reliable noninvasive detection of significant coronary stenosis based on qualitative visual assessment. The purpose of this study was to determine the accuracy of MDCT to quantify the degree of coronary stenosis as compared to quantitative coronary angiography (QCA) using two different reconstruction methods. METHODS: We studied 69 coronary artery lesions from 38 consecutive patients that underwent 16-slice MDCT as a part of research study, which enrolled consecutive subjects scheduled for clinically indicated invasive coronary angiography. Nine coronary artery lesions with motion artifacts, heavily calcified plaques or stents were excluded from the analysis. The degree of stenosis was calculated by two independent readers non-blinded to the location of the stenosis, but blinded to the results of the QCA. MDCT luminal diameters were measured in cross-sectional multi-planar reformatted (CS-MPR) images created perpendicular to the centerline of the vessel and in 5 mm thin-slab maximum intensity projections (MIP) parallel to the long axis of the vessel. Both MDCT methods were compared against QCA. RESULTS: The mean degree of stenosis as measured by MDCT was closely correlated to QCA for both methods (CS-MPR versus QCA: 61 +/- 23% versus 64 +/- 29%; r2 = 0.83, p < 0.001 and MIP versus QCA: 64 +/- 22% versus 64 +/- 29%; r2 = 0.84, p < 0.001 for MIP. Bland-Altman analysis demonstrated a negative bias of the degree of stenosis of -2.8 +/- 12% using CS-MPR and a minimally positive bias of 0.6 +/- 12% for MIP. In stratified analysis for lesion severity (mild, 0-40%; moderate, 41-70% or severe, > 70%) the agreement between both CS-MPR and MIP was high when compared to QCA (kappa = 0.74 and 0.71, respectively). CONCLUSION: Multi-detector spiral CT permits accurate quantitative assessment of the degree of coronary stenosis in selected data sets of sufficient quality using both cross-sectional and longitudinal vessel reconstructions.
Multi-detector computed tomography (MDCT) permits detection of coronary plaque. However, noise and blurring impair accuracy and precision of plaque measurements. The aim of the study was to evaluate MDCT post-processing based on non-linear image deblurring and edge-preserving noise suppression for measurements of plaque size. Contrast-enhanced MDCT coronary angiography was performed in four subjects (mean age 55 +/- 5 years, mean heart rate 54 +/- 5 bpm) using a 16-slice scanner (Siemens Sensation 16, collimation 16 x 0.75 mm, gantry rotation 420 ms, tube voltage 120 kV, tube current 550 mAs, 80 mL of contrast). Intravascular ultrasound (IVUS; 40 MHz probe) was performed in one vessel in each patient and served as a reference standard. MDCT vessel cross-sectional images (1 mm thickness) were created perpendicular to centerline and aligned with corresponding IVUS images. MDCT images were processed using a deblurring and edge-preserving noise suppression algorithm. Then, three independent blinded observers segmented lumen and outer vessel boundaries in each modality to obtain vessel cross-sectional area and wall area in the unprocessed MDCT cross-sections, post-processed MDCT cross-sections and corresponding IVUS. The wall area measurement difference for unprocessed and post-processed MDCT images relative to IVUS was 0.4 +/- 3.8 mm2 and -0.2 +/- 2.2 mm2 (p < 0.05), respectively. Similarly, Bland-Altman analysis of vessel cross-sectional area from unprocessed and post-processed MDCT images relative to IVUS showed a measurement difference of 1.0 +/- 4.4 and 0.6 +/- 4.8 mm2, respectively. In conclusion, MDCT permitted accurate in vivo measurement of wall area and vessel cross-sectional area as compared to IVUS. Post-processing to reduce blurring and noise reduced variability of wall area measurements and reduced measurement bias for both wall area and vessel cross-sectional area.
We explored quantitative parameters of image quality in consecutive patients undergoing 64-slice multi-detector computed tomography (MDCT) coronary angiography for clinical reasons. Forty-two patients (36 men, mean age 61 +/- 11 years, mean heart rate 63 +/- 10 bpm) underwent contrast-enhanced MDCT coronary angiography with a 64-slice scanner (Siemens Sensation 64, 64 mm x 0.6 mm collimation, 330 ms tube rotation, 850 mAs, 120 kV). Two independent observers measured the overall visualized vessel length and the length of the coronary arteries visualized without motion artifacts in curved multiplanar reformatted images. Contrast-to-noise ratio was measured in the proximal and distal segments of the coronary arteries. The mean length of visualized coronary arteries was: left main 12 +/- 6 mm, left anterior descending 149 +/- 25 mm, left circumflex 89 +/- 30 mm, and right coronary artery 161 +/- 38 mm. On average, 97 +/- 5% of the total visualized vessel length was depicted without motion artifacts (left main 100 +/- 0%, left anterior descending 97 +/- 6%, left circumflex 98 +/- 5%, and right coronary artery 95 +/- 6%). In 27 patients with a heart rate < or = 65 bpm, 98 +/- 4% of the overall visualized vessel length was imaged without motion artifacts, whereas 96+/-6% of the overall visualized vessel length was imaged without motion artifacts in 15 patients with a heart rate > 65 bpm (p < 0.001). The mean contrast-to-noise ratio in all measured coronary arteries was 14.6 +/- 4.7 (proximal coronary segments: range 15.1 +/- 4.4 to 16.1 +/- 5.0, distal coronary segments: range 11.4 +/- 4.2 to 15.9 +/- 4.9). In conclusion, 64-slice MDCT permits reliable visualization of the coronary arteries with minimal motion artifacts and high CNR in consecutive patients referred for non-invasive MDCT coronary angiography. Low heart rate is an important prerequisite for excellent image quality.
PURPOSE: To compare the measurement variability for coronary artery calcium (CAC) measurements using mineral mass compared with a modified Agatston score (AS) or volume score (VS) with multi-detector CT (MDCT) scanning, and to estimate the potential impact of these methods on the design of CAC progression studies. MATERIALS AND METHODS: We studied 162 consecutive subjects (83 women, 79 men, mean age 51 +/- 11 years) from a general Caucasian community-based cohort (Framingham Heart Study) with duplicate runs of prospective electrocardiographically-triggered MDCT scanning. Each scan was independently evaluated for the presence of CAC by four experienced observers who determined a "modified" AS, VS and mineral mass. RESULTS: Of the 162 subjects, CAC was detected in both scans in 69 (42%) and no CAC was detected in either scan in 72 (45%). Calcium scores were low in the 21/162 subjects (12%) for whom CAC was present in one but not the other scan (modified AS < 20 in 20/21 subjects, mean AS 4.6 +/- 1.9). For all three quantification algorithms, the inter- and intraobserver correlation were excellent (r > 0.96). However, the mean interscan variability was significantly different between mineral mass, modified AS, and VS (coefficient of variation 26 +/- 19%, 41 +/- 28% and 34 +/- 25%, respectively; p < 0.04), with significantly smaller mean differences in pair-wise comparisons for mineral mass compared with modified AS (p < 0.002) or with VS (p < 0.03). The amount of CAC but not heart rate was an independent predictor of interscan variability (r = -0.638, -0.614 and -0.577 for AS, VS, and mineral mass, respectively; all p < 0.0001). The decreased interscan variability of mineral mass would allow a sample size reduction of 5.5% compared with modified AS for observational studies of CAC progression and for randomized clinical trials. CONCLUSION: There is significantly reduced interscan variability of CAC measurements with mineral mass compared with the modified AS or VS. However, the measurement variability of all quantification methods is predicted by the amount of CAC and is inversely correlated to the extent of partial volume artifacts. Moreover, the improvement of measurement reproducibility leads to a modest reduction in sample size for observational epidemiological studies or randomized clinical trials to assess the progression of CAC.
Explore the source record for details and available documents.
INTRODUCTION: The present study investigated the threshold-dependent variability of coronary artery calcification (CAC) measurements and the potential to quantify CAC in contrast-enhanced multi-detector row-computed tomography (MDCT). METHODS: We compared the mean CT attenuation of CAC to luminal contrast enhancement of the coronary arteries in 30 patients (n = 30) undergoing standard coronary contrast-enhanced spiral MDCT. The modified Agatston score [AS], calcified plaque volume [CV], and mineral mass [MM]) at four different thresholds (130, 200, 300, and 400 HU) were measured in 50 patients who underwent non-contrast-enhanced MDCT. RESULTS: Mean CT attenuation of CAC was similar to the attenuation of the contrast-enhanced coronary lumen (CAC 297.1 +/- 68.7 HU versus 295 +/- 65 HU (p < 0.0001), respectively). Above a threshold of 300 HU CAC measurements significantly varied to standard measurements obtained at a threshold of 130 HU (p < 0.0001). The threshold-dependent variation of MM measurements was significantly smaller than for AS and CV (130 HU versus 400 HU: 63, 75, and 81, respectively; p < 0.001). These differences resulted in a change of age and gender based percentile category for AS in 78% of subjects. DISCUSSION: We demonstrated that CAC measurements are threshold dependent with MM measurements having significantly less variation than AS or CV. Due to the similarity of mean CT attenuation of CAC and the contrast-enhanced coronary lumen accurate quantification of CAC may be difficult in standard coronary contrast-enhanced spiral MDCT.