Monitoring stiffness changes in lesions after radiofrequency ablation at different temperatures and durations of ablation.

The variations in the stiffness or stiffness contrast of lesions resulting from radiofrequency (RF) ablation of canine liver tissue at different temperatures and for different ablation durations at a specified temperature are analyzed. Tissue stiffness, in general, increases with temperature; however, an anomaly exists around 80 degrees C, where the stiffness of the lesion is lower than that of the lesion ablated at 70 degrees C. On the other hand, the stiffness increases monotonically with the duration of ablation. Plots illustrating the ratio of mean strains in normal canine liver tissue to mean strains in ablated thermal lesions demonstrate the variation in the stiffness contrast of the thermal lesions. The contrast-to-noise ratio (CNRe) of the lesions, which serves as an indicator of the detectability of the lesions under the different experimental imaging conditions described above, is also presented. The results presented in this paper show that the elastographic depiction of stiffer thermal lesions is better, in terms of the CNRe parameter. An important criterion in the elastographic depiction of RF-ablated regions of tissue is the trade-off between ablation temperature and duration of ablation. Tissue necrosis can occur either by ablating tissue to high temperatures for short durations or to lower temperatures for longer durations. In this paper, we attempt to characterize the elastographic depiction of thermal lesions under these different experimental conditions. This paper provides results that may be utilized by practitioners of RF ablation to decide the ablation temperature and duration, on the basis of the strain images of normal liver tissue and ablated thermal lesions discussed in this paper.

Animals↗

Improvements in elastographic contrast-to-noise ratio using spatial-angular compounding.

Spatial-angular compounding is a new technique developed for improving the signal-to-noise ratio (SNR) in elastography. Under this method, elastograms of a region-of-interest (ROI) are obtained from a spatially weighted average of local strain estimated along different insonification angles. In this article, we investigate the improvements in the strain contrast and contrast-to-noise ratio (CNR) of the spatially compounded elastograms. Spatial angular compounding is also applied and evaluated in conjunction with global temporal stretching. Quantitative experimental results obtained using a single-inclusion tissue-mimicking phantom demonstrate that the strain contrast reduces slightly but the CNR improves by around 8 to 13 dB. We also present experimental spatial angular compounding results obtained from an in vitro thermal lesion in canine liver tissue embedded in a gelatin phantom that demonstrate the improved visual characteristics (due to the improved CNR) of the compound elastogram. The experimental results provide guidelines for the practical range of maximum insonification angles and estimates of the optimum angular increment.

Animals↗

Wavelet denoising of displacement estimates in elastography.

Wavelet shrinkage denoising of the displacement estimates to reduce noise artefacts, especially at high overlaps in elastography, is presented in this paper. Correlated errors in the displacement estimates increase dramatically with an increase in the overlap between the data segments. These increased correlated errors (due to the increased correlation or similarity between consecutive displacement estimates) generate the so-called "worm" artefact in elastography. However, increases in overlap on the order of 90% or higher are essential to improve axial resolution in elastography. The use of wavelet denoising significantly reduces errors in the displacement estimates, thereby reducing the worm artefacts, without compromising on edge (high-frequency or detail) information in the elastogram. Wavelet denoising is a term used to characterize noise rejection by thresholding the wavelet coefficients. Worm artefacts can also be reduced using a low-pass filter; however, low-pass filtering of the displacement estimates does not preserve local information such as abrupt change in slopes, causing the smoothing of edges in the elastograms. Simulation results using the analytic 2-D model of a single inclusion phantom illustrate that wavelet denoising produces elastograms with the closest correspondence to the ideal mechanical strain image. Wavelet denoising applied to experimental data obtained from an in vitro thermal lesion phantom generated using radiofrequency (RF) ablation also illustrates the improvement in the elastogram noise characteristics.

Algorithms↗

Elastographic versus x-ray CT imaging of radio frequency ablation coagulations: an in vitro study.

Techniques to image elasticity parameters (i.e., elastography) have recently become of great interest to researchers. In this paper we use conventional ultrasound elastography and x-ray CT to image radio frequency (RF) ablation sites of excised canine liver enclosed in gelatin. Thermal coagulations of different sizes were produced by applying the RF procedure for various times and end point temperatures. Dimensions, areas and volumes computed from CT and elastography were compared with those on whole mount pathology specimens. Ultrasound elastography exhibited high contrast for the thermal coagulations and performed better than CT. The correlation between pathology and elastography for this sample set of 40 thermal coagulations (r = 0.94 for volume estimation, r = 0.87 for area estimation) is better than the correlation between pathology and CT (r = 0.89 for volume estimation, r = 0.82 for area estimation).

Animals↗

Impact of gas bubbles generated during interstitial ablation on elastographic depiction of in vitro thermal lesions.

OBJECTIVE: Artifacts from gas bubble formation during radio frequency ablation along with the poor intrinsic contrast between normal and treated regions (zone of necrosis) are considerable problems for the visualization of the necrotic region on conventional sonography. Sonographic elastography is very effective for visualizing the zone of necrosis, but it uses the same echo signals to estimate strain as those used to form gray scale images. Thus, the impact of gas bubbles on strain images or elastograms must be investigated. METHODS: Radio frequency ablation was performed in vitro on liver tissue samples, approximately 40 x 40 x 20 mm, encased in 80-mm cubed gelatin phantoms. Elastograms generated at different instants during the ablation procedures were obtained on a real-time scanner with a 5-MHz linear array. Sequences of elastograms illustrate the growth of the thermal lesion. RESULTS: Degradation of the distal boundary of the thermal lesion was observed. The degradation was confined to the lower-fifth quadrant of the thermal lesion. However, accurate estimates of lesion areas could still be obtained by extrapolation of the thermal lesion boundary. CONCLUSIONS: Elastograms of thermal lesions in vitro can be obtained during radio frequency ablation. Some loss of thermal lesion boundary information on strain images was observed in regions where attenuation due to gas bubbles reduced the signal-noise ratio of the echo signals.

Animals↗

Noise reduction using spatial-angular compounding for elastography.

Ultrasound elastography has developed into an imaging modality suitable for detection and diagnosis of cancers in the breast, prostate, and thyroid and for monitoring ablative therapies in the liver, kidneys, and other sites. In this article, a new approach is described that enables the reduction of noise artifacts in elastography without a significant reduction in either the contrast or spatial resolution. The technique uses angular-weighted compounding of local angular strains estimated from echo signals scanned at different insonification angles. Strain estimated along angular insonification directions can be separated into strain tensor components along the axial (direction of compression) and lateral directions. The mechanical stimulus is applied only along one direction. Angular-weighting factors are derived from the relationship between the axial and lateral strains under the assumption of tissue incompressibility. Experimental results using a uniformly elastic, tissue-mimicking phantom demonstrate the improvement in the signal-to-noise ratio obtained with angular-weighted compounding. Variation in the signal-to-noise ratio obtained using different angular increments also is investigated. Elastograms obtained from an inclusion phantom also demonstrate the improvement in contrast detail resolution obtained using spatial-angular compounding.

Algorithms↗

Elastographic measurement of the area and volume of thermal lesions resulting from radiofrequency ablation: pathologic correlation.

OBJECTIVE: Elastography is a promising tool for visualizing the zone of necrosis in liver tissue resulting from radiofrequency tumor ablation. Because heat-ablated tissues are stiffer than normal untreated tissue, elastography may prove useful for following up patients who undergo radiofrequency ablative therapy. We sought to report the initial evaluations of the reliability of elastography for delineating thermal lesion boundaries in liver tissue by comparing lesion dimensions determined by elastography with the findings at whole-mount pathology. MATERIALS AND METHODS: Radiofrequency ablation was performed in vitro on liver tissue specimens encased in gelatin phantoms. The imaging plane for elastography was perpendicular to the axis of the radiofrequency electrode so that the ablated region was around the center of the plane. To obtain three-dimensional visualization of thermal lesions, we reconstructed the lesions from multiple elastograms by linearly translating the elastographic scanning plane. Pathology photographs were obtained in the same image plane used for elastography by slicing through the gelatin and tissue phantom using external markers. We used digitized gross pathology photographs obtained at a specified slice thickness to compute the areas and volumes of the lesions. These measurements were then compared to the measurements obtained from the elastograms. RESULTS: In a sample of 40 thermal lesions, we obtained a correlation between in vitro elastographic and pathologic measurements of r = 0.9371 (p < 0.00001) for area estimates and r = 0.979 (p < 0.00001) for volume estimates. CONCLUSION: We found excellent correlation between the measurements of the dimensions, areas, and volumes of thermal lesions that were based on elastographic images and the measurements that were based on digitized pathologic images. When compared with digitized pathologic measurements, elastographic measurements showed a tendency to slightly underestimate both the areas and volumes of lesions. Nevertheless, elastography is a reliable technique for delineating thermal lesions resulting from radiofrequency ablation.

Animals↗