PubMed Health⌕ Search

Biomedical subjects

Ulrich Stierle

Publications and source records attributed to Ulrich Stierle.

9 recordsLinked to original sources

A critical reappraisal of the Ross operation: renaissance of the subcoronary implantation technique?

BACKGROUND: The autograft procedure, an option in aortic valve replacement, has undergone technical evolution. A considerable debate about the most favorable surgical technique in the Ross operation is still ongoing. Originally described as a subcoronary implant, the full root replacement technique is now the most commonly used technique to perform the Ross principle. METHODS AND RESULTS: Between June of 1994 and June of 2005, the original subcoronary autograft technique was performed in 347 patients. Preoperative, perioperative, and follow-up data were collected and analyzed. Mean patient age at implantation was 44+/-13 years (range 14 to 71 years; 273 male, 74 female). Bicuspid valve morphology was present in 67%. The underlying valve disease was aortic regurgitation in 111 patients, stenosis in 46 patients, combined lesion in 188 patients, and active endocarditis in 22 patients (in 2 patients without stenosis or regurgitation). Concomitant procedures were performed in 130 patients. Clinical and echocardiographic follow-up visits were obtained annually (mean follow up 3.9+/-2.7 years, 1324 patient-years; completeness of follow-up 99.4%). The in-hospital mortality rate was 0.6% (n =2), and the late mortality was 1.7% (n=6), with 5 noncardiac deaths (4 cancer, 1 multiorgan failure after noncardiac surgery) and 1 cardiac death (sudden death). At last follow-up, 94% of the surviving patients were in New York Heart Association class I. Ross procedure-related valvular reoperations were necessary in 9 patients: Three received autograft explants, 5 received homograft explants, and 1 received a combined auto- and homograft explant. At last follow-up visit, autograft/homograft regurgitation grade II was present in 5/10 patients and grade III in 4/0. Maximum/mean pressure gradients were 7.4+/-6.2/3.7+/-2.1 mm Hg across the autograft and 15.3+/-9.4/7.6+/-5.0 mm Hg across the right ventricular outflow tract, respectively. Aortic root dilatation was not observed. Freedom from any valve-related intervention was 95% at 8 years (95% confidence interval 91% to 99%). CONCLUSIONS: Midterm follow-up of autograft procedures according to the original Ross subcoronary approach proves excellent clinical and hemodynamic results, with no considerable reoperation rates. Revival of the original subcoronary Ross operation should be taken into account when considering the best way to install the Ross principle.

Adolescent↗

Ross procedure and left ventricular mass regression.

BACKGROUND: Return of left ventricular mass to normal is considered to be a favorable result of aortic valve replacement. The Ross procedure provides near normal hemodynamics and thus allows studies of left ventricular (LV) reverse remodeling. LV mass regression may be influenced by surgical technique (subcoronary [SC] versus root replacement [RR]). METHODS AND RESULTS: Data from the German Ross Registry were analyzed. A total of 646 patients (mean age: 43.6+/-12.7 years, range: 16 to 71 years; SC technique n=295, RR technique n=351) underwent a Ross procedure in 7 participating centers from 1990 to 2004. The patients underwent preoperative and postoperative echocardiographic evaluations. Mean follow-up time was 3.5+/-2.5 years (range 0.12 to 13.7 years). Follow-up completeness was 97%. The LV mass index (LVMI) decreased significantly during follow-up in both groups (SC: 209+/-53 preoperatively to 154+/-48 at 1-year follow-up, [P<0.01 versus preoperative values] to 149+/-51 g/m2 at 2-year follow-up, [P=NS 1-year versus 2-year follow-up] versus RR: from 195+/-56 preoperatively to 144+/-51 at 1-year follow-up [P<0.01 versus preoperative values] to 140+/-49 g/m2 [P=NS 1-year versus 2-year follow-up]). LVMI regression remained stagnant 1 year after the Ross procedure in most patients in both groups. On the basis of multivariate analysis, predictors for incomplete LVMI regression after the autograft procedure were high preoperative LVMI, smoking, and uncontrolled diastolic hypertension. CONCLUSIONS: At mid-term echocardiographic follow-up, patients of both groups had favorable autograft hemodynamics. Risk factors for incomplete postoperative LVMI regression in our study were smoking and persistent diastolic hypertension. This emphasizes the importance of cessation of smoking and treatment of arterial hypertension, even in younger patients, after corrected aortic valve disease.

Adolescent↗

Clinical significance of myoglobin and troponin-T in short-lasting severe myocardial ischemia.

BACKGROUND: Myoglobin, cardiac troponin-T and creatine phosphokinase are biochemical indicators of acute coronary syndromes, however, the clinical significance in myocardial ischemia is not well established. Our aim was to elucidate their release kinetics in a well-defined short-lasting myocardial ischemia. METHODS: A coronary sinus lactate study with incremental atrial pacing was performed in 27 patients with significant coronary stenosis. Troponin-T, myoglobin and creatine phosphokinase samples were withdrawn from the coronary sinus and a peripheral vein before, 1, 5, 10, 30, 45 min and 1, 2, 3, 6, 12 h after pacing. RESULTS: Pacing stress induced a severe myocardial ischemia with a duration of 5.8+/-1.6 min, angina pectoris in 22/27, significant ST-segment depressions in 25/27 patients (0.34+/-0.11 mV) and a frank cardiac lactate production of 37.6+/-19.9%. Serum troponin-T levels as well as creatine phosphokinase were normal at baseline and remained unchanged. A transient rise of myoglobin after 1 h with a peak coronary sinus concentration after 2 h (101.5+/-39.0 microg/l) and peripheral venous concentration (90.5+/-32.5 microg/l) after 3 h (134.3% and 120.7%, respectively, of the upper normal limit, p<0.002) followed myocardial ischemia. In a control group of 20 patients without heart disease all variables remained unchanged. CONCLUSIONS: Severe short-lasting myocardial ischemia did not enhance troponin-T or creatine phoshokinase concentrations, whereas a transient slight cardiac release of myoglobin with a delay of 1 h and a coronary sinus peak concentration after 2 h was detected. This may be due to a rapid reperfusion effect on ischemic myocardium or minor damaged single myocardial cells.

Aged↗

Mid-term findings on echocardiography and computed tomography after RVOT-reconstruction: comparison of decellularized (SynerGraft) and conventional allografts.

OBJECTIVE: The immune response against human-leucocyte-antigens on donor-cells may be an important factor contributing to the degeneration of allograft-valves. We have previously reported that the use of the decellularized allograft SynerGraft (CryoLife) reduces the immunologic response of the allograft-recipient. In this study we compare the echocardiographic and computed tomography angiographic (CTA) findings of SynerGrafts with conventional cryopreserved allografts. METHODS: 22 patients who received a pulmonary SynerGraft (SG-group) (21 during a Ross-procedure) underwent CTA and resting echocardiography (median: 10 months postoperatively). 47 randomly chosen patients who underwent a Ross-procedure served as controls (C-group) (median: 32 months postoperatively). RESULTS: Neither the pressure gradients (mean: SG=9+/-4 vs C=10+/-4mmHg; P=0.64) across the allograft, nor the effective orifice area (EOAI) (SG=0.93+/-0.80 vs C=0.93+/-0.42cm(2)/m(2); P=0.96) differed between the groups. The EOAI showed a significant correlation with the smallest allograft-conduit-area measured on CTA (r=0.81; P<0.001) which was most frequently (n=34) found in the proximal postvalvular tubular part of the conduit. Calcifications (n=11) or a fibroproliferative reaction (n=15) were rarely observed. Overall, there were no radiologic differences between the groups. On CTA, the smallest diameter of the allograft-conduits was significantly smaller than the diameter given on the cryopreservation protocol (SG=16+/-3 and C=17+/-3mm vs 25mm in both groups; P<0.001 each) whereas the diameter of the distal part of the allograft was not (SG=24+/-2, P=0.066, and C=25+/-3mm, P=0.82). CONCLUSIONS: Despite a significant shorter follow-up in the SynerGraft-group, no functional or radiologic differences were observed as compared to control-patients. The smallest diameter is located almost exclusively at the proximal level of allograft-conduits.

Adult↗

Hemodynamic performance following the Ross operation: comparison of two different techniques.

BACKGROUND AND AIM OF THE STUDY: The Ross operation as aortic valve replacement has undergone technical evolution. Originally described as a subcoronary implant, the full-root replacement technique is now more common worldwide. It remains unclear which of the two techniques has the better results. Hence, the hemodynamic performances of the two implantation methods, as applied by two experienced centers, were compared as part of the German Ross Registry. METHODS: In total, 132 (Group 1, root replacement, mean age 40 +/- 14 years) and 249 (Group 2, subcoronary implant, mean age 48 +/- 14 years) consecutively operated patients were compared clinically and echocardiographically. Data were analyzed focusing on pulmonary autograft and homograft function at mid-term (2.78 +/- 1.89 versus 2.26 +/- 2.11 years). RESULTS: Echocardiography revealed autograft peak systolic gradients of 5.0 +/- 2.7 mmHg for Group 1 and 6.7 +/- 3.7 mmHg for Group 2 (p < 0.05), and an indexed effective orifice area (EOA) of 1.98 +/- 0.57 cm2/m2 and 1.64 +/- 0.43 cm2/m2 (p < 0.05), respectively. Homograft peak systolic gradients were 15.6 +/- 9.0 mmHg and 11.7 +/- 6.8 mmHg for Groups 1 and 2 (p < 0.05) respectively, and the indexed EOA with regard to the homograft was 1.08 +/- 0.49 cm2/m2 and 1.26 +/- 0.50 cm2/m2 (p < 0.05). Autograft insufficiency grade > I was present in 1.5% (2/132) of Group 1 and 2.8% (7/249) of Group 2 patients. Pulmonary insufficiency grade > I was 17.4% (23/132) for Group 1 and 4.8% (12/249) for Group 2 (p < 0.05). CONCLUSION: Although both groups enjoyed excellent hemodynamics in the mid-term, the root replacement technique had the advantage of larger annulus diameters and greater aortic EOA. Clinically relevant autograft regurgitation in both groups was gratifyingly rare, and seemed to be independent of surgical technique. Long-term durability of the more demanding subcoronary technique versus the problems of larger dimensions of the sinus of Valsalva and sinotubular junction in the free-root technique, remains to be proven. Apparent differences in pulmonary homograft hemodynamics can most likely be explained by surgical differences, younger patients in Group 1, and by homograft variation.

Adult↗

Midterm results of the Ross procedure preserving the patient's aortic root.

BACKGROUND: Since the early 1990s, the pulmonary autograft is predominantly implanted as a freestanding root for less aortic valve regurgitation is reported. However, there is a certain risk of dilatation of the root over time potentially impairing valve function. We favor since 8 years the original subcoronary or inclusion technique to preserve the root of the patient as a restrain to dilatation. METHODS AND RESULTS: Between June 1994 and May 2002 the subcoronary (n=228) and inclusion technique (n=17) were performed in 245 patients (191 male, 54 female), mean age 45.7+/-13.4 (15-70) years. The underlying aortic valve disease was an aortic insufficiency in n=83, stenosis in n=48, a combined aortic valve disease in n=111 and an acute endocarditis in n=19 patients. Previous aortic valve surgery was performed in n=23. Last follow-up investigations (within last year) including echocardiography was performed at a mean follow-up of 29.4+/-24.7 months (553.7 patient years). Hospital mortality was n=2, late mortality n=4 (all noncardiac). Two patients were lost to follow-up (99% complete clinical follow-up). Reoperations were necessary in n=7 valves (autograft: endocarditis n=1, malpositioning n=1, leaflet prolapse n=1; homograft: stenosis n=2, insufficiency n=2). Autograft insufficiency (AI) was AI 0 in n=154, AI I n=66, AI II n=8. The maximum/mean pressure gradient across the autograft was 6.6+/-3.4 (2.1 to 25.9)/3.6+/-1.8 (1.2 to 13.2) mm Hg, respectively. Homograft insufficiency was 0 in n=167, I in n=54, II in n=9, and III in n=1. Maximum and mean transhomograft pressure gradients were 11.7+/-6.8 (2.2 to 42.6)/6.2+/-3.8 (1.2 to 24.5) mm Hg. Most patients were NYHA class I (n=214), class II (n=19), class III (n=2). Significant aortic root dilatation was not observed. CONCLUSIONS: Aortic valve replacement with a pulmonary autograft in the subcoronary or inclusion technique provides excellent hemodynamics with no root dilatation at least in a mid term postoperative period. Transhomograft pressure gradients are slightly increased. Longer term results with special emphasis on the pulmonary homograft are necessary.

Adolescent↗

Up to 7 years' experience with valve-sparing aortic root remodeling/reimplantation for acute type A dissection.

BACKGROUND: Aortic valve-sparing operations for acute type A dissection are appealing and innovative but less well defined surgical techniques requiring further evaluation. METHODS: We reviewed all consecutive patients with acute type A dissection who underwent either the remodeling (group 1, n = 21) or the reimplantation valve-sparing technique (group 2, n = 15) since October 1994. Patients were followed up clinically and echocardiographically for as long as 41.3 months (group 1) and 87 months (group 2). RESULTS: Hospital mortality was 19% (n = 4) for group 1 and 20% (n = 3) for group 2. Permanent new neurologic symptomatology occurred in 1 patient (3.6%). Three patients in group 1 required reoperation owing to redissection. No patient had an aortic insufficiency of more than grade 1. No late neurologic or thrombembolic events occurred. There was no statistically significant difference between both groups with respect to clinical and hemodynamic data. CONCLUSIONS: Remodeling and reimplantation aortic valve-preserving operations in acute type A dissection can be performed with adequate perioperative risk and excellent midterm aortic valve function. We found no evidence of one technique being superior to the other, however durability of the remodeling technique needs critical consideration especially in Marfan syndrome and when glue is used.

Acute Disease↗

Evaluation of the decellularized pulmonary valve homograft (SynerGraft).

BACKGROUND AND AIM OF THE STUDY: Rejection is thought to contribute to the degeneration of valved homografts. A novel cryopreserved decellularized homograft valve (SynerGraft; CryoLife, Inc.) offers the unique opportunity to gain new insight into the immunology of homograft implantation and its significance for valve function. METHODS: Twenty-four patients (group I; mean age 37 +/- 11 years) underwent implantation of a pulmonary SynerGraft and were examined at one and six months postoperatively; 22 patients (group II; mean age 41 +/- 17 years) with conventional homografts served as controls. Temperature, C-reactive protein (CRP) levels and white blood cell count (WBC) were studied perioperatively. Follow up included echocardiography and anti-human leukocyte antigen (HLA) class I antibody determination. RESULTS: Significantly lower temperatures were measured in group I (p = 0.019). CRP level and WBC each increased postoperatively, but did not differ between groups. During follow up, none of the SynerGraft patients became positive for anti-HLA antibodies, compared with 66% of controls (p = 0.011). Homograft diameter and valve orifice area were decreased significantly at one month after surgery in groups I and II (25 +/- 1 versus 18 +/- 3 mm; 25 +/- 1 versus 19 +/- 2 mm, respectively; p <0.001 both groups). Transvalvular pressure gradients significantly increased during follow up. CONCLUSION: Implantation of the SynerGraft pulmonary homograft appeared safe, and though evidence was found of a reduced immunologic response after SynerGraft implantation this (unexpectedly) did not translate into any hemodynamic advantage. Hence, factors other than rejection appear as the main contributions to the observed functional changes.

Adult↗

Valve-sparing aortic root remodeling for pulmonary autograft aneurysm.

The case is reported of a 42-year-old patient who underwent a Ross procedure for aortic valve insufficiency due to endocarditis in 1991, using the free-standing root technique. Autograft valve function was stable for up to 10 years postoperatively, though dilation of the autograft root occurred. With an increasing size of the root diameter (50 mm), however, progressive aortic regurgitation developed which necessitated reoperation. A valve-sparing autograft root remodeling procedure, according to Yacoub, was performed with excellent resultant valve function.

Adult↗