PubMed Health⌕ Search

Biomedical subjects

Ulrike Dydak

Publications and source records attributed to Ulrike Dydak.

6 recordsLinked to original sources

Cerebral metabolic alterations in McLeod syndrome.

The X-linked McLeod neuroacanthocytosis syndrome is a multisystem disorder with central nervous system manifestations resembling Huntington's disease. We examined 5 McLeod patients and 5 asymptomatic heterozygous females with fast multiple spin-echo spectroscopic imaging. Three patients with pronounced psychiatric or cognitive manifestations had pathological N-acetyl aspartate/(creatine + choline) ratios in frontal, temporal, and insular areas, with an individual pattern. Two patients with a severe choreatic movement disorder had unilateral thalamic alterations. One patient with moderate movement disorder and personality disorder had bilateral occipital alterations. One female heterozygote had unilateral insular metabolic alterations, possibly indicating subclinical cerebral involvement. Although the prominent psychiatric and cognitive manifestations in McLeod patients suggest significant and widespread cortical abnormalities, previous neuroradiological and histopathological data had not revealed definite extrastriatal pathology. Our findings demonstrating metabolic abnormalities in different brain regions of McLeod patients might either reflect neuronal dysfunction due to impaired basal ganglia-thalamo-cortical circuits or subtle structural alterations in the particular cerebral areas.

Adult↗

Minimum-norm reconstruction for sensitivity-encoded magnetic resonance spectroscopic imaging.

In this work we propose minimum-norm reconstruction as a means to enhance the spatial response behavior in parallel spectroscopic MRI. By directly optimizing the shape of the spatial response function (SRF), the new method accounts for coil sensitivity variation across individual voxels and their side lobes. In this fashion, it mitigates the signal contamination and side-lobe aliasing, to which previous techniques are susceptible at low resolution. Although the computational burden is higher, minimum-norm reconstruction is shown to be feasible using an iterative algorithm. Benefits in terms of SRF shape and artifact suppression are demonstrated.

Algorithms↗

Prostate spectroscopy at 3 Tesla using two-dimensional S-PRESS.

Two-dimensional (2D) strong-coupling point-resolved spectroscopy (S-PRESS) is introduced as a novel approach to (1)H MR spectroscopy (MRS) in the prostate. The technique provides full spectral information and allows for an accurate characterization of the citrate (Cit) signal. The method is based on acquiring a series of PRESS spectra with constant total echo time (TE). The indirect dimension is encoded by varying the relative lengths of the first and second TEs (TE(1) + TE(2) = TE). In the resulting 2D spectra, only the signal of strongly coupled spin systems is spread into the second dimension, which leads to more clearly arranged spectra. Furthermore, the spectral parameters of Cit (coupling constant J and chemical shift difference delta of the AB spin system) can be determined with high accuracy in vivo. The sequence is analytically optimized for maximal "strong coupling peaks" of Cit at 3T. 2D S-PRESS spectra are compared with JPRESS spectra in vitro as well as in vivo.

Algorithms↗

MR spectroscopy and spectroscopic imaging: comparing 3.0 T versus 1.5 T.

In vivo magnetic resonance spectroscopy (MR spectroscopy) offers the unique possibility to monitor human brain metabolism in a noninvasive way. At 3.0 T, MR spectroscopy not only profits from higher available signal compared with 1.5 T, but from increased chemical shift dispersion as well. These gains may be exchanged into increased spatial resolution or speed in MR spectroscopic imaging. However, some adverse effects related to the higher field strength, such as increased field inhomogeneities and sequence restrictions caused by safety limitations need to be considered. These require protocol adaptations and technical advances that have not yet fully found their way onto the clinical platform. If neglected, effects such as chemical shift misregistration at higher field strength can lead to wrong localizations or loss of signals of certain metabolites, which can intervene with the diagnostic value of a spectrum. This article tries to give an understanding of the potentials and challenges of MR spectroscopy at the higher field strength of 3.0 T, and to give insight into new techniques that hopefully soon will become available in daily clinical routine to fully exploit all benefits of the higher field strength.

Brain↗

Optimizing PRESS localized citrate detection at 3 Tesla.

Analytical methods are used to characterize the response of the strongly coupled two-spin system of citrate to point-resolved spectroscopy (PRESS)-based sequences at 3 T. The signal output is analyzed line by line, as well as in the Cartesian product operator basis. Patterns with a periodicity of 80.9 ms are identified. Furthermore, it is shown that at TE = n . 80.9 ms (n in {0,1,2,...}), the spin evolution can be described without direct reference to strong coupling terms. The theoretical results are found to be in good agreement with in vivo experiments. These results can be used to design protocols for prostate MRS and MRSI at 3 T, and give guidelines for optimizing spin-echo-based acquisition schemes for detecting two-spin systems at arbitrary field strengths.

Adult↗

Parallel spectroscopic imaging with spin-echo trains.

A reduction in scan time in spectroscopic imaging (SI) can be achieved by both fast and reduced k-space sampling. This work presents an ultrafast SI technique that combines the two approaches. The synergy of multiple spin-echo (MSE) acquisition and sensitivity encoding (SENSE) enables high-resolution SI to be performed within a clinically acceptable scan time. MSE-SENSE-SI with echo train lengths ranging from one to four echoes is evaluated with respect to SNR and spatial response function by means of in vitro experiments. It is shown that acquiring two spin-echoes (SEs) per acquisition yields a good practical trade-off among scan time, SNR, and spatial response. The clinical feasibility of the technique is demonstrated in a patient with an astrocytoma, and SI data are obtained with an image matrix of 24 x 24 in just over 2 min.

Astrocytoma↗