PubMed Health⌕ Search

Biomedical subjects

Uri Dinnar

Publications and source records attributed to Uri Dinnar.

4 recordsLinked to original sources

Theoretical model and experimental study of red blood cell (RBC) deformation in microchannels.

The motion and deformation of red blood cells (RBCs) flowing in a microchannel were studied using a theoretical model and a novel automated rheoscope. The theoretical model was developed to predict the cells deformation under shear as a function of the cells geometry and mechanical properties. Fluid dynamics and membrane mechanics are incorporated, calculating the traction and deformation in an iterative manner. The model was utilized to evaluate the effect of different biophysical parameters, such as: inner cell viscosity, membrane shear modulus and surface to volume ratio on deformation measurements. The experimental system enables the measurement of individual RBCs velocity and their deformation at defined planes within the microchannel. Good agreement was observed between the simulation results, the rheoscope measurements and published ektacytometry results. The theoretical model results imply that such deformability measuring techniques are weakly influenced by changes in the inner viscosity of the cell or the ambient fluid viscosity. However, these measurements are highly sensitive to RBC shear modulus. The shear modulus, estimated by the model and the rheoscope measurements, falls between the values obtained by micropipette aspiration and laser trapping. The study demonstrates the integration of a theoretical model with a microfabricated device in order to achieve a better understanding of RBC mechanics and their measurement using microfluidic shear assays. The system and the model have the potential of serving as quantitative clinical tools for diagnosing deformability disorders in RBCs.

Erythrocyte Deformability↗

Correlation between erythrocytes deformability and size: a study using a microchannel based cell analyzer.

The deformability of erythrocytes is of great importance for oxygen delivery in the microcirculation [Lipowsky, H.H., 2005. Microvascular rheology and hemodynamics. Microcirculation 12, 5-15]. Aging of erythrocytes is associated with a reduction in deformability and also in size. The present work describes an automated cell analyzer which utilizes a glass microchannel and advanced image processing software. Erythrocytes suspended in a high viscosity medium are filmed flowing through the microchannel. Under these conditions, the cells assume different orientations and undergo varying deformations according to their location in the velocity profile. The cell analyzer enables the measurement of individual erythrocyte velocity, deformability and volume at varying depths within the microchannel. The volume of the cells is calculated based on the experimental data and a fluid mechanics model. The results obtained show that, on average, the deformability of the cells increases with increase in their size. Additionally, the behavior of RBCs in a microchannel is investigated, showing promising diagnostic possibilities.

Cell Size↗

An automated cell analysis sensing system based on a microfabricated rheoscope for the study of red blood cells physiology.

An automated rheoscope has been developed, utilizing a microfabricated glass flow cell, high speed camera and advanced image-processing software. RBCs suspended in a high viscosity medium were filmed flowing through a microchannel. Under these conditions, RBCs exhibit different orientations and deformations according to their location in the velocity profile. The rheoscope system produces valuable data such as velocity profile of RBCs, spatial distribution within a microchannel and deformation index (DI) curves. The variation of DI across the channel height, due to change in shear stress, was measured carrying implications for diffractometry methods. These curves of DI were taken at a constant flow rate and cover most of the relevant shear stress spectrum. This is an improvement of the existing techniques for deformability measurements and may serve as a diagnostic tool for certain blood disorders. The DI curves were compared to measurements of the flowing RBCs velocity profile. In addition, we found that RBCs flowing in a microchannel are mostly gathered in the center of the flow and maintain a characteristic spatial distribution. The spatial distribution in this region changes slightly with increasing flow rate. Hence, the system described, provides means for examining the behavior of individual RBCs, and may serve as a microfabricated diagnostic device for deformability measurement.

Biosensing Techniques↗

Floating electrode dielectrophoresis.

In practice, dielectrophoresis (DEP) devices are based on micropatterned electrodes. When subjected to applied voltages, the electrodes generate nonuniform electric fields that are necessary for the DEP manipulation of particles. In this study, electrically floating electrodes are used in DEP devices. It is demonstrated that effective DEP forces can be achieved by using floating electrodes. Additionally, DEP forces generated by floating electrodes are different from DEP forces generated by excited electrodes. The floating electrodes' capabilities are explained theoretically by calculating the electric field gradients and demonstrated experimentally by using test-devices. The test-devices show that floating electrodes can be used to collect erythrocytes (red blood cells). DEP devices which contain many floating electrodes ought to have fewer connections to external signal sources. Therefore, the use of floating electrodes may considerably facilitate the fabrication and operation of DEP devices. It can also reduce device dimensions. However, the key point is that DEP devices can integrate excited electrodes fabricated by microtechnology processes and floating electrodes fabricated by nanotechnology processes. Such integration is expected to promote the use of DEP devices in the manipulation of nanoparticles.

Animals↗