PubMed Health⌕ Search

Biomedical subjects

Ute Pyell

Publications and source records attributed to Ute Pyell.

3 recordsLinked to original sources

Indirect laser-induced fluorescence detection for capillary electrophoresis using a frequency-doubled diode laser.

A blue (452 nm) frequency-doubled diode laser with a quasi-cw optical output power of 10 microW is used for indirect laser-induced fluorescence detection in combination with the capillary electrophoretic separation of inorganic anions. As fluorescing probe ion the anion of 8-hydroxypyrene-1,3,6-trisulfonic acid (HPTS) was selected having an absorption maximum of 454 nm in alkaline medium. Employing a capillary coated with linear acrylamide, baseline separation of eight inorganic anions was possible within 5 min. With a separation buffer containing 50 micromol.L(-1) HPTS and 10 mmol.L(-1) lysine the limits of detection for sulfate, nitrite, nitrate, azide, thiocyanate, and chlorate were between 0.9 and 4.7 micromol.L(-1). Separation of chloride and sulfate was achieved by adding 0.25 mmol.L(-1) calcium hydroxide to the separation buffer. Inorganic anions in several mineral and tap water samples have been determined with the technique developed and results are compared to data obtained by ion chromatography in combination with conductivity detection after conductivity suppression.

Anions↗

Near-field thermal lens detection at 257 nm as an alternative to absorption spectrometric detection in combination with electromigrative separation techniques.

A device is presented that permits detection of analytes absorbing electromagnetic radiation at lambda = 257 nm (in fused-silica capillaries with 75-microm i.d.) via the near-field thermal lens effect. The detector was realized by using a frequency-doubled argon ion laser as pump laser and a laser diode (emission wavelength, 633 nm) coupled into a monomode optical fiber as probe laser. Comparing the performance of this detector to the performance of a commercial absorption spectrometric detector working at lambda = 257 nm equipped with a unit for on-column detection in fused-silica capillaries showed a substantial improvement in detection limits (up to 30-fold improvement) for the near-field thermal lens detector (NF-TLD). The feasibility of the NF-TLD for sensitive detection of nonfluorescent analytes in real samples after separation by micellar electrokinetic chromatography was shown taking the determination of nitroaromatic compounds in contaminated water from a former ammunition plant as an example. Dependence of the thermal lens signal on pump laser power, velocity of the mobile phase, and chopper frequency was investigated. A linear calibration range over 2 orders of magnitude was obtained.

Journal Article↗