PubMed Health⌕ Search

Biomedical subjects

Uwe R Müller

Publications and source records attributed to Uwe R Müller.

7 recordsLinked to original sources

Protein detection using biobarcodes.

Over the past 50 years the development of assays for the detection of protein analytes has been driven by continuing demands for higher levels of sensitivity and multiplexing. The result has been a progression of sandwich-type immunoassays, starting with simple radioisotopic, colorimetric, or fluorescent labeling systems to include various enzymatic or nanostructure-based signal amplification schemes, with a concomitant sensitivity increase of over 1 million fold. Multiplexing of samples and tests has been enabled by microplate and microarray platforms, respectively, or lately by various molecular barcoding systems. Two different platforms have emerged as the current front-runners by combining a nucleic acid amplification step with the standard two-sided immunoassay. In both, the captured protein analyte is replaced by a multiplicity of oligonucleotides that serve as surrogate targets. One of these platforms employs DNA or RNA polymerases for the amplification step, while detection is by fluorescence. The other is based on gold nanoparticles for both amplification as well as detection. The latter technology, now termed Biobarcode, is completely enzyme-free and offers potentially much higher multiplexing power.

Biosensing Techniques↗

Detection of protein analytes via nanoparticle-based bio bar code technology.

We describe a new format for the recently introduced bio bar code technology, which improves the dose response over 10,000-fold and thereby makes this technique analytically useful. Unlike other ultrasensitive protein detection methods, such as immuno-PCR or immuno-RCA, the bio bar code technique does not employ any enzymes to achieve detection limits in the attomolar range. By sandwiching a target between a magnetic bead and an amplifier nanoparticle, a multiplicity of bar code oligonucleotides are released for each captured target analyte. These surrogate bar code targets are then hybridized to microarrays and detected with silver-amplified gold nanoparticle probes. Using PSA detection as a model, we demonstrate a linear dose response over at least 4 orders of magnitude in both target concentration and concomitant signal and a 1000-fold improvement in detection limit compared to the best ELISA system.

Antibodies, Monoclonal↗

SNP identification in unamplified human genomic DNA with gold nanoparticle probes.

Single nucleotide polymorphisms (SNPs) comprise the most abundant source of genetic variation in the human genome. SNPs may be linked to genetic predispositions, frank disorders or adverse drug responses, or they may serve as genetic markers in linkage disequilibrium analysis. Thus far, established SNP detection techniques have utilized enzymes to meet the sensitivity and specificity requirements needed to overcome the high complexity of the human genome. Herein, we present for the first time a microarray-based method that allows multiplex SNP genotyping in total human genomic DNA without the need for target amplification or complexity reduction. This direct SNP genotyping methodology requires no enzymes and relies on the high sensitivity of the gold nanoparticle probes. Specificity is derived from two sequential oligonucleotide hybridizations to the target by allele-specific surface-immobilized capture probes and gene-specific oligonucleotide-functionalized gold nanoparticle probes. Reproducible multiplex SNP detection is demonstrated with unamplified human genomic DNA samples representing all possible genotypes for three genes involved in thrombotic disorders. The assay format is simple, rapid and robust pointing to its suitability for multiplex SNP profiling at the 'point of care'.

Genome, Human↗

Gold nanoparticle probe-based gene expression analysis with unamplified total human RNA.

Microarray-based gene expression analysis plays a pivotal role in modern biology and is poised to enter the field of molecular diagnostics. Current microarray-based gene expression systems typically require enzymatic conversion of mRNA into labeled cDNA or cRNA. Conversion to cRNA involves a target amplification step that overcomes the low sensitivity associated with commonly used fluorescent detection methods. Herein, we present a novel enzyme-free, microarray-based gene expression system that uses unamplified total human RNA sample as the target nucleic acid. The detection of microarray-bound RNA molecules is accomplished by targeting the poly-A tail with an oligo-dT20 modified gold nanoparticle probe, signal amplification by autometallography, and subsequent measurement of nanoparticle-mediated light scattering. The high sensitivity afforded by the nanoparticle probes allows differential gene expression from as little as 0.5 microg unamplified total human RNA in a 2 h hybridization without the need for elaborate sample labeling steps.

Biosensing Techniques↗

Homogeneous detection of unamplified genomic DNA sequences based on colorimetric scatter of gold nanoparticle probes.

Nucleic acid diagnostics is dominated by fluorescence-based assays that use complex and expensive enzyme-based target or signal-amplification procedures. Many clinical diagnostic applications will require simpler, inexpensive assays that can be done in a screening mode. We have developed a 'spot-and-read' colorimetric detection method for identifying nucleic acid sequences based on the distance-dependent optical properties of gold nanoparticles. In this assay, nucleic acid targets are recognized by DNA-modified gold probes, which undergo a color change that is visually detectable when the solutions are spotted onto an illuminated glass waveguide. This scatter-based method enables detection of zeptomole quantities of nucleic acid targets without target or signal amplification when coupled to an improved hybridization method that facilitates probe-target binding in a homogeneous format. In comparison to a previously reported absorbance-based method, this method increases detection sensitivity by over four orders of magnitude. We have applied this method to the rapid detection of mecA in methicillin-resistant Staphylococcus aureus genomic DNA samples.

Bacterial Proteins↗

Gold nanoparticle-based detection of genomic DNA targets on microarrays using a novel optical detection system.

The development of a nanoparticle-based detection methodology for sensitive and specific DNA-based diagnostic applications is described. The technology utilizes gold nanoparticles derivatized with thiol modified oligonucleotides that are designed to bind complementary DNA targets. A glass surface with arrays of immobilized oligonucleotide capture sequences is used to capture DNA targets, which are then detected via hybridization to the gold nanoparticle probes. Amplification with silver allows for detection and quantitation by measuring evanescent wave induced light scatter with low-cost optical detection systems. Compared to Cy3-based fluorescence, silver amplified gold nanoparticle probes provide for a approximately 1000-fold increase in sensitivity. Furthermore, direct detection of non-amplified genomic DNA from infectious agents is afforded through increased specificity and even identification of single nucleotide polymorphisms (SNP) in human genomic DNA appears feasible.

Bacterial Proteins↗

Reduction of autofluorescence on DNA microarrays and slide surfaces by treatment with sodium borohydride.

Microarray technology is currently being used extensively in functional genomics research and modern drug discovery and development. Henceforward, tremendous application potential for this technology exists in the fields of clinical diagnostics and prognostics, pathology, and toxicology for high-throughput analysis of "disease" gene expression. However, the major hurdle now in this technology is not the performance of the arrays but rather the efficient reproducibility of the hybridization signal intensity in a fluorescence-based analysis. The sensitivity of fluorescence detection on an array is to a large extent limited by the amount of background signal arising due to nonspecifically bound probes and fluorescence that is intrinsically associated with the chip substrate and/or the attached target DNA, the so-called autofluorescence. Here, we describe a simple and efficient method to reduce autofluorescence from undetermined sources on coated glass slides with and without DNA arrays. This sodium borohydride-mediated reduction process resulted in significantly lower and more even background fluorescence. This in turn extended the dynamic range of detection and reduced the average coefficient of variation of fluorescent signal ratios on DNA microarrays in addition to improving the detection of genes that are expressed at a low level.

Borohydrides↗