PubMed Health⌕ Search

Biomedical subjects

V A Kadhiresan

Publications and source records attributed to V A Kadhiresan.

6 recordsLinked to original sources

Automatic capture verification by charge-neutral sensing.

Automatic capture verification can prolong pulse generator longevity and increase patient safety. However, the detection of evoked response following pacing is complicated due to afterpotentials caused by polarization of electrodes. This study describes a new capture verification scheme, which neutralizes the charges between the pacing electrodes. The hypothesis of the charge-neutral sensing is that the afterpotentials in the ring and the tip are opposite in polarity when pacing in a bipolar mode between ring and tip. Summing the unipolar signals sensed at the tip and the ring should effectively cancel the afterpotentials. This scheme was implemented in an external computer based system and tested during pacemaker implant/replacement on 23 patients during VVI pacing (17 acutely implanted leads and 6 chronic leads). Surface ECG was recorded to provide a marker for capture and noncapture. The pacing voltage was gradually decreased until a noncapture beat was noted. To avoid fusion beats, the pacing rate was programmed approximately 50% higher than the intrinsic rate. The evoked response was high pass filtered and the integral average was calculated for both capture and noncapture beats. The system signal to noise ratio (SNR) was expressed as ratio of the minimum integral average of all capture beats to the maximum integral average of all noncapture beats. The system SNR was 8.6 +/- 1.3 (mean +/- S.E.M; range 1.5-22.8), indicating that the charge-neutral sensing method has, on average, a ninefold safety margin in providing capture verification. Further, evaluation is needed to fully assess this feature in patients with chronic leads.

Aged↗

Properties of single motor units in medial gastrocnemius muscles of adult and old rats.

1. The purpose of this study was to determine the role of motor unit remodelling in the deficit that develops in the maximum isometric tetanic force (Fo) of whole medial gastrocnemius (MGN) muscles in old compared with adult rats. The Fo values and morphological data were determined for MGN muscles and eighty-two single motor units in muscles of adult (10-12 months) and sixty-two units in those of old (24-26 months) F344 rats. During an unfused tetanus, fast and slow (S) motor units were identified by the presence and absence of sag, respectively. Fast-fatigable (FF) and fast-fatigue-resistant (FR) units were classified by fatigue indices less than or greater than 0.50, respectively. 2. For old rats, whole MGN muscle Fo was 29% less than the value of 11.2 N measured for adult rats. The deficit in whole muscle Fo of old rats resulted from equivalent decreases in the number of motor units, 16% smaller than the adult value of ninety-seven, and in the mean motor unit Fo value, 14% less than the adult value of 117 mN. 3. With ageing, little motor unit remodelling occurred in FR units, whereas the S and FF motor units demonstrated dramatic, but opposing, changes. For S units, the number of units remained constant, but the number of fibres per motor unit increased 3-fold from 57 to 165. In contrast, the number of FF units decreased by 34% and the number of fibres per motor unit of the remaining units decreased to 86% of the adult value of 333. The age-related remodelling of motor units appeared to involve denervation of fast muscle fibres with reinnervation of denervated fibres by axonal sprouting from slow fibres.

Aging↗

Tubular nerve guide and epineurial repair: comparison of techniques for neurorrhaphy.

Experiments were conducted on 36 male, Sprague-Dawley rats. In 10 animals, neurorrhaphy was performed on the peroneal nerve with epineurial repair and, in 11 animals, with a tubular polyethylene nerve guide. The authors tested the hypothesis that, following transient denervation of a skeletal muscle by transection of a peroneal nerve, the restoration of maximum force and of maximum specific force developed after insertion of a tubular nerve guide, will not be different from that developed after microsurgical epineurial neurorrhaphy. The contractile properties of the extensor digitorum longus (EDL) muscle, innervated by the peroneal nerve, were evaluated after an average of 116 days. The maximum tetanic force of EDL muscles with epineurial repair and nerve guide were 84 percent and 75 percent, respectively, of the value for control EDL muscles. The specific forces of the muscles in both groups were not different from the control values. The conclusion is that, following stabilization after transection and repair, each of the two methods was equally effective in restoring the ability of the muscle to develop force.

Anastomosis, Surgical↗

Tenotomy and repair of latissimus dorsi muscles in rats: implications for transposed muscle grafts.

The functional properties of latissimus dorsi (LTD) muscles were evaluated 160 to 180 days after tenotomy and repair, when grafts had stabilized. Our hypothesis was that, compared with control LTD muscles, LTD grafts would develop less absolute force and power but that the specific force and normalized power would not differ. Expressed as a percentage of the value for control LTD muscles, values for grafts were 67% for muscle mass, 74% for mean single fiber cross-sectional area, 56% for maximum absolute isometric tetanic force, 64% for maximum absolute average force during shortening, and 70% for maximum absolute power. Compared with control LTD muscles, grafts showed no significant differences either in the number of fibers in the total muscle cross section or in the optimum velocity for the development of power. When force and power of grafts were normalized for total fiber cross-sectional area and mass, respectively, only the value for maximum specific force (84% of control value) was significant. The mechanisms responsible for the decrease in specific force after tenotomy and repair are not known. In contrast to the deficit in maximum specific force, the 30% deficit in maximum absolute power of grafts compared with control LTD muscles was explained completely by the 33% smaller muscle mass.

Animals↗

An apparatus to measure in vivo biomechanical behavior of dorsi- and plantarflexors of mouse ankle.

We developed an apparatus to quantify the biomechanical behavior of the dorsi- and plantarflexor muscles of the ankle of an anesthetized mouse. When the dorsi- or plantarflexor muscle group is activated by electrical stimulation of either the peroneal or tibial nerve, the apparatus measures the moment developed about the ankle during isometric, isovelocity shortening, or isovelocity lengthening contractions. Displacements may be performed over the full 105 degrees range of ankle motion with an angular resolution of 0.09 degrees. Bidirectional isovelocity ramps in ankle angle up to 1,100 degrees/s are possible and are equivalent to maximum velocities of 2.3 fiber lengths/s (Lf/s) for the fibers in tibialis anterior muscle and 11.9 Lf/s for those in gastrocnemius muscle. During single contractions of the dorsi- and plantarflexor muscle groups at 37 degrees C and with both knee and ankle joint at 90 degrees neutral position, the isometric tetanic force developed was 1.4 and 3.3 N, power output at 2.2 Lf/s was 3.1 and 5.9 mW, and power absorption at 0.5 Lf/s was 4.9 and 9.0 mW, respectively. These values are in reasonable agreement with data from the same muscle groups tested in situ. We conclude that the apparatus provides valid measurements of force and power of the dorsi- and plantarflexor muscle groups.

Animals↗

A simple Hill element-nonlinear spring model of muscle contraction biomechanics.

The purpose of this study was to develop a model to predict the mechanical response of muscles during isometric tetanic, afterloaded isotonic and isovelocity shortening contractions. Two versions of the model were developed. Both incorporated a contractile element that obeyed a Hill force-velocity relationship and a series elastic element. In a quadratic spring version, the series elastic element force was represented as proportional to the square of the stretch; in a cubic spring version, it was represented as proportional to the cube of the stretch. Both versions provided closed-form equations for response predictions that involved four independent parameters. Once the four parameters were chosen, each of these responses could be predicted. Model validity was established by comparing predicted and observed responses in slow and fast hindlimb muscles of rodents. Significant model-predicted responses seldom differed by more than 15% from experimental values. The model can provide insights into how changes in individual properties affect the overall mechanical behavior of muscles in a variety of circumstances and reduce the need for collection of experimental data.

Animals↗