PubMed HealthSearch

Biomedical subjects

V A Umans

Publications and source records attributed to V A Umans.

At least 19 recordsLinked to original sources

Comparison of usefulness of computer assisted continuous 48-h 3-lead with 12-lead ECG ischaemia monitoring for detection and quantitation of ischaemia in patients with unstable angina.

AIMS: The selection of ECG leads used for ST monitoring may influence detection and quantitation of ischaemia. METHODS: We compared on-line continuous 48-h 12-lead against 3-lead ST monitoring in 130 unstable angina patients (Mortara. ELI-100). Onset and offset of ST episodes were defined by the lead with the first > or = 100 microV ST change relative to baseline and the lead with the latest return to baseline ST level, respectively. ST episodes were calculated for 12 leads and 3 leads (V2, V5, III) separately. RESULTS: ST episodes were detected in 88 patients (77%) by 12-lead and in 71 patients (62%) by 3-lead ST monitoring (P < 0.02). The median number (25.75%) of episodes/patient was 1 (0.3) for 3-lead and 2 (1.6) for 12-lead (P < 0.0001). The total duration of ischaemia detected during 12-lead far exceeded 3-lead monitoring: 12.3 (1, 58.2) and 1.7 (0, 23.3) min respectively (P < 0.0001). The probability of recurrent ischaemia declined most during the first 24 h of monitoring. After a period without ST changes of 1, 12, 24 and 36 h, the probabilities of recurrent ischaemia were 63, 31, 14 and 9%, respectively. CONCLUSIONS: Continuous 12-lead ST monitoring increases detection rate and duration of ST episodes compared to 3-lead ST monitoring. The use of continuous 12-lead ECG monitoring devices on emergency wards and coronary care units is recommended.

Angina, Unstable

Inter- and intra-observer variability in the qualitative categorization of coronary angiograms.

The ABC classification of the American College of Cardiology and the American Heart Association is a commonly used categorization to estimate the risk and success of intracoronary intervention, as well as the probability of restenosis. To evaluate the reliability of qualitative angiogram readings, we randomly selected 200 films from single lesion angioplasty procedures. A repeated visual assessment (> or = 2 months interval) by two independent observers resulted in kappa values of inter and intra-observer variability for the ABC lesion classification and for all separate items that compile it. Variability in assessment is expressed in percentage of total agreement, and in kappa value, which is a parameter of the agreement between two or more observations in excess of the chance agreement. Percentage of total agreement and kappa value was 67.8% and 0.33 respectively for the ABC classification, indicating a poor agreement. Probably this is due to the deficiency of strict definitions. Further investigation has to demonstrate whether improvement can be achieved using complete and detailed definitions without ambiguity, and consensus after panel assessment.

Coronary Angiography

Clinical and angiographic comparison of matched patients with successful directional coronary atherectomy or stent implantation for primary coronary artery lesions.

OBJECTIVES: This study was designed to compare the long-term clinical and angiographic effects of successful directional atherectomy and stent implantation and to examine whether restenosis is related to the mechanism of lumen improvement as well as the extent of lumen gain. BACKGROUND: Directional atherectomy and coronary stent implantation have been shown to achieve a more optimal immediate result that may lead to a more favorable long-term angiographic outcome and fewer target vessel revascularizations than does angioplasty. However, it remains to be determined whether one of the devices used in these interventions provides consistently better results than the other. METHODS: To allow meaningful comparisons a prospectively collected series of 117 patients successfully treated with atherectomy were individually matched with a prospectively collected series of 117 patients successfully treated with stent implantation. Matching for baseline characteristics identified patients with identical lesion location and lesion severity, and immediate and late angiographic and clinical outcome were compared. To evaluate the possibility of a procedure effect on restenosis, patients were further matched for both immediate angiographic outcome and baseline characteristics, providing 150 matched patients for comparison. As confirmatory analysis, multivariate models were constructed to predict late lumen diameter. RESULTS: Matching resulted in two comparable groups with equivalent baseline clinical and stenosis characteristics (n = 117 pairs). Atherectomy led to a smaller immediate gain than stenting and, because late loss was similar in both groups, stenting resulted in a larger late lumen (1.96 +/- 0.51 vs. 1.66 +/- 0.55 mm, p < 0.0001). When patients were matched for immediate gain and baseline characteristics (n = 75 pairs), lumen loss was more pronounced after atherectomy, and thus the minimal lumen diameter at follow-up differed significantly between the two groups (1.66 +/- 0.53 vs. 1.90 +/- 0.47 mm, p = 0.004). This beneficial angiographic effect of stenting was accompanied by a reduced need for repeat interventions. Multivariate analysis confirmed the independent effect of the interventional device used, whereby less loss and greater lumen diameter at follow-up were predicted for stent implantation than for atherectomy. CONCLUSIONS: Successful stent implantation provided a more favorable long-term angiographic outcome and lower rates of restenosis and need for target lesion revascularization than did atherectomy. This favorable effect of stenting not only is related to a larger, immediate gain, but also seems to attenuate late lumen loss.

Angioplasty, Balloon, Coronary

A comparison of hirudin with heparin in the prevention of restenosis after coronary angioplasty. Helvetica Investigators.

BACKGROUND: The likelihood of restenosis is a major limitation of coronary angioplasty. We studied whether hirudin, a highly selective inhibitor of thrombin with irreversible effects, would prevent restenosis after angioplasty. We compared two regimens of recombinant hirudin with heparin. METHODS: We randomly assigned 1141 patients with unstable angina who were scheduled for angioplasty to receive one of three treatments: (1) a bolus dose of 10,000 IU of heparin followed by an intravenous infusion of heparin for 24 hours and subcutaneous placebo twice daily for three days (382 patients), (2) a bolus dose of 40 mg of hirudin followed by an intravenous infusion of hirudin for 24 hours and subcutaneous placebo twice daily for three days (381 patients), or (3) the same hirudin regimen except that 40 mg of hirudin was given subcutaneously instead of placebo twice daily for three days (378 patients). The primary end point was event-free survival at seven months. Other end points were early cardiac events (within 96 hours), bleeding and other complications of the study treatment, and angiographic measurements of coronary diameter at six months of follow-up. RESULTS: At seven months, event-free survival was 67.3 percent in the group receiving heparin, 63.5 percent in the group receiving intravenous hirudin, and 68.0 percent in the group receiving both intravenous and subcutaneous hirudin (P = 0.61). However, the administration of hirudin was associated with a significant reduction in early cardiac events, which occurred in 11.0, 7.9, and 5.6 percent of patients in the respective groups (combined relative risk with hirudin, 0.61; 95 percent confidence interval, 0.41 to 0.90; P = 0.023). The mean minimal luminal diameters in the respective groups on follow-up angiography at six months were 1.54, 1.47, and 1.56 mm (P = 0.08). CONCLUSIONS: Although significantly fewer early cardiac events occurred with hirudin than with heparin, hirudin had no apparent benefit with longer-term follow-up.

Angina, Unstable

Mechanism of high-speed rotational atherectomy and adjunctive balloon angioplasty revisited by quantitative coronary angiography: edge detection versus videodensitometry.

High-speed rotational coronary atherectomy (RA) is primarily used to treat complex lesions. Quantitative angiographic analysis of such complex lesions by edge detection is often unsuitable, whereas videodensitometry, measuring vessel dimensions independently of the target stenosis contours, may offer potential advantages. To gain insight into the operative mechanism of RA and to study the agreement between the two quantitative angiographic methods in measuring the minimal luminal cross-sectional area, the edge detection and videodensitometry techniques were applied to coronary angiograms of 21 lesions in 19 patients with symptoms who underwent successful RA and balloon angioplasty (BA). Obstruction diameter as determined by edge detection increased from 1.00 +/- 0.31 mm before intervention to 1.35 +/- 0.29 mm after RA (p < 0.001) and further increased to 1.74 +/- 0.33 mm after adjunctive BA (p > 0.001). The mean between-method difference (edge detection minus videodensitometry) was 0.34 mm2 before intervention, 0.13 mm2 after RA, and 0.09 mm2 after adjunctive BA (not significant). The standard deviation of the differences decreased from +/- 0.87 mm2 before intervention to +/- 0.80 mm2 after RA (not significant) and increased after BA significantly to +/- 1.21 mm2 (p < 0.05). Thus edge detection and videodensitometry provided equivalent immediate angiographic results after RA and adjunctive BA. The good agreement after RA may reflect the operative mechanism of RA, which by ablation of noncompliant plaque material yields a circular symmetric lumen with smooth surface. The increased dispersion of the between-method differences observed after adjunctive BA presumably results from dissections, plaque ruptures, and loss of luminal smoothness after balloon dilatation.

Absorptiometry, Photon

Angiographic, ultrasonic, and angioscopic assessment of the coronary artery wall and lumen area configuration after directional atherectomy: the mechanism revisited.

The purpose of the present study was to use the complementary information of angiography, intravascular ultrasound, and intracoronary angioscopy before and after directional atherectomy to characterize the postatherectomy appearance of vessel wall contours and the mechanism of lumen enlargement. Directional coronary atherectomy aims at debulking rather than dilating a coronary artery lesion. The selective removal of the plaque may potentially minimize the vessel wall damage and lead to subsequent better late outcome. Whether plaque removal is the main mechanism of action has only to be assessed indirectly by angiography and warrants further investigation with detailed analysis of luminal changes and vessel wall damage by ultrasound and direct visualization with angioscopy. Twenty-six patients have been investigated by quantitative angiography, intravascular ultrasound, and intracoronary angioscopy (n = 19) before and after atherectomy. In addition, all retrieved specimens were microscopically examined. Ultrasound imaging showed an increase in lumen area from 1.95 +/- 0.70 mm2 to 7.86 +/- 2.16 mm2 at atherectomy. The achieved gain mainly resulted from plaque removal because plaque plus media area decreased from 18.16 +/- 4.47 mm2 to 13.13 +/- 3.10 mm2. Vessel wall stretching (i.e., change in external elastic lamina area) accounted for only 15% of lumen area gain. Luminal gain was higher in noncalcified (6.52 +/- 2.12 mm2) lesions than in lesions containing deeply located calcium (5.19 +/- 0.99 mm2) and lowest in superficially calcified lesions (5.41 +/- 2.41 mm2). Ultrasound imaging identified an atherectomy byte in 85% of the cases, whereas angioscopy revealed such a crevice in 74%. The complementary use of the three techniques revealed an underestimation of the presence of dissection/tear and new thrombus by angiography (10% and 4%) and ultrasound imaging (12% and 0%) compared with angioscopy (26% and 21%). The combined use of angiography, ultrasound, and angioscopy reveals that the postatherectomy luminal lining is not as regular and smooth as that seen by angiography. Luminal enlargement with atherectomy is achieved by plaque excision rather than arterial expansion.

Aged

Immediate and late outcome of excimer laser and balloon coronary angioplasty: a quantitative angiographic comparison based on matched lesions.

OBJECTIVES: This study sought to compare acute lumen changes and late lumen narrowing during and after excimer laser-assisted balloon angioplasty, measured by quantitative coronary angiography, with the immediate and long-term outcome of balloon angioplasty alone. BACKGROUND: Although excimer laser coronary angioplasty is used as an adjunct or alternative to balloon angioplasty, limited comparative data exist regarding the immediate and long-term efficacy of excimer laser-assisted balloon angioplasty versus balloon angioplasty alone. METHODS: A series of 53 lesions in 47 consecutive patients successfully treated with excimer laser-assisted balloon angioplasty were individually matched after completion of 6-month follow-up angiography with 53 successfully treated balloon angioplasty lesions according to vessel location, preprocedural minimal lumen diameter and reference diameter. Immediate and long-term angiographic results were assessed by an automated lumen contour detection algorithm. RESULTS: Before intervention in the laser and balloon angioplasty groups, respectively, minimal lumen diameter (mean +/- SD) was 0.73 +/- 0.47 and 0.74 +/- 0.46 mm, and reference diameter was 2.71 +/- 0.42 and 2.72 +/- 0.41 mm. Laser angioplasty was followed by adjunctive balloon dilation in 50 lesions. Mean balloon diameter at maximal inflation was similar in both treatment groups (2.61 +/- 0.32 and 2.65 +/- 0.38 mm, respectively), resulting in similar minimal lumen diameters after intervention of 1.77 +/- 0.41 and 1.78 +/- 0.34 mm, respectively. At follow-up angiography, minimal lumen diameter after excimer laser-assisted balloon angioplasty was 1.17 +/- 0.63 mm, and that after balloon angioplasty alone was 1.46 +/- 0.67 mm (p = 0.02). The angiographic restenosis rates at follow-up using the 50% diameter stenosis cutoff criterion were 57% and 34%, respectively (p = 0.02). CONCLUSIONS: Quantitative angiographic analysis of a matched group of 106 successfully treated coronary lesions showed a similar immediate outcome but reduced long-term efficacy of excimer laser-assisted balloon angioplasty compared with that after balloon angioplasty alone.

Algorithms

Evaluation of recombinant hirudin (CGP 39,393/TMREVASC) in the prevention of restenosis after percutaneous transluminal coronary angioplasty. Rationale and design of the HELVETICA trial, a multicentre randomized double blind heparin controlled study.

One of the main areas of interest in interventional cardiology is the understanding, and ultimate prevention of restenosis after an initially successful percutaneous transluminal coronary angioplasty. Restenosis is the recurrence of luminal narrowing following angioplasty, and still frustrates the late results in the treatment of angina pectoris. Experimental, pathological and clinical studies suggest that restenosis may occur via activation of the coagulation cascade, platelet activation and thrombus formation. Thrombin itself is identified as the most potent platelet activator, and has a pivotal role in the coagulation system. Furthermore, thrombin directly mediates smooth muscle cell proliferation by stimulating thrombin receptors at the smooth muscle cell surface. Thrombus indirectly induces excessive intimal smooth muscle cell proliferation by means of released mitogens (growth factors), which may contribute to late restenosis. Therefore direct and irreversible thrombin blockade by hirudin is deemed to be effective in the prevention of restenosis following angioplasty. The HELVETICA trial is a multicentre, randomized, double-blind heparin-controlled study, designed to compare the effects of two dose regimens of recombinant-hirudin (CGP 39,393/TMRevasc) with those of heparin on event-free survival, safety, tolerability and luminal renarrowing using quantitative coronary angiography no later than 26 weeks after the coronary angioplasty procedure.

Adult

Differences in restenosis propensity of devices for transluminal coronary intervention. A quantitative angiographic comparison of balloon angioplasty, directional atherectomy, stent implantation and excimer laser angioplasty. CARPORT, MERCATOR, MARCATOR, PARK, and BENESTENT Trial Groups.

With the increasing clinical application of new devices for percutaneous coronary revascularization, maximization of the acute angiographic result has become widely recognized as a key factor in maintained clinical and angiographic success. What is unclear, however, is whether the specific mode of action of different devices might exert an additional independent effect on late luminal renarrowing. The purpose of this study was to investigate such a difference in the degree of provocation of luminal renarrowing (or 'restenosis propensity') by different devices, among 3660 patients, who had 4342 lesions successfully treated by balloon angioplasty (n = 3797), directional coronary atherectomy (n = 200), Palmaz-Schatz stent implantation (n = 229) or excimer laser coronary angioplasty (n = 116) and who also underwent quantitative angiographic analysis pre- and post-intervention and at 6-month follow-up. To allow valid comparisons between the groups, because of significant differences in coronary vessel size (balloon angioplasty = 2.62 +/- 0.55 mm, directional coronary atherectomy = 3.28 +/- 0.62 mm, excimer laser coronary angioplasty = 2.51 +/- 0.47 mm, Palmaz-Schatz = 3.01 +/- 0.44 mm; P < 0.0001), the comparative measurements of interest selected were the 'relative loss' in luminal diameter (RLoss = loss/vessel size) to denote the restenosis process, and the 'relative lumen at follow-up' (RLfup = minimal luminal diameter at follow up/vessel size) to represent the angiographic outcome. For consistency, lesion severity pre-intervention was represented by the 'relative lumen pre' (RLpre = minimal luminal diameter pre/vessel size) and the luminal increase at intervention was measured as 'relative gain' (relative gain = gain/ vessel size). Differences in restenosis propensity between devices was evaluated by univariate and multivariate analysis. Multivariate models were constructed to determine relative loss and relative lumen at follow-up, taking account of relative lumen pre-intervention, lesion location, relative gain, vessel size and the device used. In addition, model-estimated relative loss and relative lumen at follow-up at given relative lumen pre-intervention relative gain and vessel size, were compared among the four groups. Significant differences were detected among the groups both with respect to these estimates, as well as in the degree of influence of progressively increasing relative gain, on the extent of renarrowing (relative loss) and angiographic outcome (relative lumen at follow-up), particularly at higher levels of luminal increase (relative gain). Specifically, lesions treated by balloon angioplasty or Palmaz-Schatz stent implantation (the predominantly 'dilating' interventions) were associated with more favourable angiographic profiles than directional atherectomy or excimer laser (the mainly 'debulking' interventions). Significant effects of lesion severity and location, as well as the well known influence of luminal increase on both luminal renarrowing and late angiographic outcome were also noted. These findings indicate that propensity to restenosis after apparently successful intervention is influenced not only by the degree of luminal enlargement achieved at intervention, but by the device used to achieve it. In view of the clinical implications of such findings, further evaluation in larger randomized patient populations is warranted.

Adult

Mechanisms of luminal enlargement and quantification of vessel wall trauma following balloon coronary angioplasty and directional atherectomy.

OBJECTIVES: The purpose of this study was to assess the dual action of lumen enlargement and vessel wall damage following either balloon angioplasty or directional atherectomy, using intracoronary ultrasound, and angioscopy. BACKGROUND: Differences in the mechanisms of action of balloon angioplasty and directional atherectomy may have a significant bearing on the immediate outcome and the restenosis rate at 6 months. METHODS: A total of 36 patients were studied before and after either balloon angioplasty (n = 18) or directional atherectomy (n = 18). Ultrasound measurements included changes in lumen area, external elastic membrane area and plaque burden. In addition, the presence and extent of dissections were assessed to derive a damage score. Angioscopic assessment of the dilated or atherectomized stenotic lesions was translated into semi-quantitative dissection, thrombus and haemorrhage scores. RESULTS: Atherectomy patients had a larger angiographic vessel size compared with the angioplasty group (3.55 +/- 0.46 mm vs 3.00 +/- 0.64 mm, P < 0.05); however, minimal lumen diameter (1.18 +/- 0.96 mm vs 0.85 +/- 0.49 mm) and plaque burden (17.04 +/- 3.69 vs 15.23 +/- 4.92 mm2) measurements did not differ significantly. As a result of plaque reduction, atherectomy produced a larger increase in luminal area than the angioplasty group (5.80 +/- 1.78 mm2 vs 2.44 +/- 1.36 mm2, P < 0.0001). Lumen increase after angioplasty was the result of 'plaque compression' (50%) and wall stretching (50%). Additionally, in both groups there was indirect angioscopic evidence of thrombus 'microembolization' as an adjunctive mechanism of lumen enlargement. Angioscopy identified big flaps in six and small intimal flaps in 11 of the atherectomized patients as compared with five and 12 patients in the angioplasty group. Changes in thrombus score following both coronary interventions were identical (0.72 +/- 3.42 points atherectomy vs -0.38 +/- 3.27 points balloon angioplasty, ns). CONCLUSIONS: Lumen enlargement after directional atherectomy is mainly achieved by plaque removal (87%), whereas balloon dilation is the result of vessel wall stretching (50%) and plaque reduction (50%). Despite the fact that the luminal gain achieved by directional atherectomy is twice that achieved with balloon angioplasty, the extent of trauma induced by both techniques seems to be similar.

Aged

Acute and long-term outcome of directional coronary atherectomy for stable and unstable angina.

The clinical efficacy and safety of directional coronary atherectomy for the treatment of stable and unstable angina were assessed in 82 patients with stable and 68 patients with unstable angina. Therefore, clinical and angiographic follow-up was obtained in a prospectively collected consecutive series of 150 atherectomy procedures. Restenosis was assessed clinically and by quantitative angiography. The overall clinical success rate of atherectomy for patients with unstable and stable angina was 88% and 91%, respectively. No significant differences were found for in-hospital event rates between the unstable and stable angina groups: death (1.5% vs 0%), myocardial infarction (10% vs 6%), and emergency bypass operation (3% vs 2%). These clinical events were related to the occurrence of abrupt occlusions (8.8% in patients with stable and 6.1% in those with unstable angina; p = NS). Clinical follow-up was achieved in 100% of the patients with stable and unstable angina at a mean interval of 923 and 903 days, respectively. Two-year survival rates were 96% and 97% in the populations with unstable and stable angina, respectively. There were no significant differences with respect to bypass surgery and angioplasty, but event-free survival at 2 years was significantly lower in the unstable (54%) than the stable (69%) angina group. Quantitative coronary angiography did not detect any difference in luminal renarrowing during the 6-month angiographic follow-up period. Although directional coronary atherectomy can be performed effectively in patients with unstable and stable angina, the long-term clinical outcome was less favorable in the unstable angina group.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged

Optimal use of directional coronary atherectomy is required to ensure long-term angiographic benefit: a study with matched procedural outcome after atherectomy and angioplasty.

OBJECTIVES: This study was designed to examine whether restenosis is related to the extent or mechanism of lumen improvement and to explore angiographic determinants of optimal atherectomy. BACKGROUND: Directional atherectomy induces a greater extent of immediate gain and late loss but has not been found to yield a better late angiographic lumen than angioplasty in randomized trials. The difference in lumen renarrowing may be related to either the extent or the mechanism of immediate gain. The design of previous studies has precluded the detection of a device-specific effect on restenosis. METHODS: A retrospective analysis was based on matching a prospectively collected series of 80 native coronary arteries successfully treated with atherectomy with a prospectively collected series of 80 native coronary arteries successfully treated with balloon angioplasty. Angiographic analysis was performed in 160 lesions to explore whether a specific device-related effect exists. Multivariate analyses were performed to determine the correlates of minimal lumen diameter at follow-up and late lumen loss and to identify the procedural characteristics for optimal atherectomy. RESULTS: Matching resulted in two comparable groups with equivalent baseline clinical and stenosis characteristics. By study design, atherectomy and angioplasty resulted in similar mean (+/- SD) immediate lumen gain (1.15 +/- 0.44 vs. 1.10 +/- 0.40 mm, p = 0.50). However, lumen loss was more pronounced after atherectomy, and, thus, the minimal lumen diameter at follow-up differed significantly between the two groups (1.78 +/- 0.57 vs. 2.00 +/- 0.56 mm, p = 0.001). Device type was retained in the multivariate analysis as an independent predictor of late minimal lumen diameter and lumen loss. Multivariate analysis identified vessel size and immediate gain as determinants of optimal atherectomy. CONCLUSIONS: Restenosis is a consequence not only of the extent of lumen improvement but also of the mechanism of vessel wall injury (debulking vs. dilating). While performing atherectomy, the operator should strive for an optimal procedural result to accommodate an increased intimal hyperplastic response.

Angioplasty, Balloon

Clinical, histologic and quantitative angiographic predictors of restenosis after directional coronary atherectomy: a multivariate analysis of the renarrowing process and late outcome.

OBJECTIVES: To characterize predictors of restenosis after successful directional atherectomy, we reviewed the clinical, angiographic and procedural data obtained during 132 consecutive procedures. METHODS: Clinical and angiographic follow-up data were obtained in a prospectively collected and consecutive series of 125 patients who underwent 132 atherectomy procedures for de novo (89%) or restenotic (11%) lesions in native coronary arteries. Restenosis was assessed clinically and by quantitative coronary angiography. A dual approach to data analysis was taken to gain insight into factors affecting the clinical outcome and vessel wall healing response. Therefore, multivariate analysis was performed to 1) determine the correlates of residual lumen diameter at follow-up (angiographic outcome), and 2) characterize the determinants of the late lumen loss (renarrowing process). RESULTS: Clinical and angiographic follow-up data after successful atherectomy were obtained in 100% and 95%, respectively. Atherectomy achieved an acute lumen gain of 1.28 +/- 0.48 mm (mean +/- SD), resulting in a minimal lumen diameter of 2.44 +/- 0.47 mm. At follow-up, the minimal lumen diameter decreased to 1.78 +/- 0.64 mm. The angiographic restenosis rate was 28% if the traditional 50% stenosis cutoff criterion was applied. Larger vessel size and postatherectomy minimal lumen diameter and right coronary or left circumflex artery lesions were independent predictors of a larger minimal lumen diameter (angiographic outcome). Lumen loss during follow-up (renarrowing process) was independently predicted by relative lumen gain and preprocedural minimal lumen diameter. CONCLUSIONS: In analyzing the long-term results of new interventional techniques such as directional atherectomy, the late lumen loss during follow-up (renarrowing process), which is characterized by the vessel wall healing response after an intervention, should be considered together with the residual lumen diameter at follow-up (clinical outcome). It is clear that whereas improved clinical outcome is associated with larger vessel size and postprocedural lumen diameter and non-left anterior descending artery location, greater relative gain at intervention is predictive of more extensive lumen renarrowing.

Aged

Proliferation and extracellular matrix synthesis of smooth muscle cells cultured from human coronary atherosclerotic and restenotic lesions.

OBJECTIVES: The purpose of this study was to examine the proliferative capacity and extracellular matrix synthesis of human coronary plaque cells in vitro. BACKGROUND: Common to both primary atherosclerosis and restenosis are vascular smooth muscle cell proliferation and production of extracellular matrix proteins. The applicability to humans of experimental animal models of these processes has been questioned. METHODS: Primary atherosclerotic and restenotic lesions were excised by percutaneous directional coronary atherectomy in 93 patients. Smooth muscle cells were cultivated by an explant technique and identified by their morphology in culture, ultrastructural features under electron microscopy and immunostaining using monoclonal antibodies to smooth muscle cell alpha-actin. Proliferation in secondary culture was assessed with growth curves and the synthesis of collagen and sulfated glycosaminoglycans by the incorporation of 3H-proline and 35S-sulfate, respectively. These studies were also performed in cells derived from human umbilical artery media. RESULTS: Success rates for primary (45%) and secondary (12%) culture of coronary cells were not influenced by clinical variables or lesion category. Primary culture success was improved by the presence of organized thrombus in the plaque and in relation to increased maximal cell density of the atherectomy specimen. Restenotic cells displayed more rapid growth than did cells of primary atherosclerotic origin, which grew in a manner similar to that of umbilical artery cells. Mean calculated population-doubling times for the three cell groups were 52 h (95% confidence interval [CI] 48 to 58 h), 71 h (95% CI 62 to 83 h) and 74 h (95% CI 65 to 84 h), respectively. Restenotic and primary atherosclerotic cells did not differ in the synthesis of collagen ([mean +/- SEM] 0.034 +/- 0.004 vs. 0.033 +/- 0.004 nmol isotope.microgram protein-1, p = NS) or sulfated glycosaminoglycans (11.47 +/- 1.07 vs. 15.37 +/- 3.10 nmol isotope.microgram protein-1, p = NS), but the coronary cells synthesized significantly more collagen and sulfated glycosaminoglycans than did umbilical artery cells (0.019 +/- 0.004 and 5.43 +/- 1.00 nmol isotope.microgram protein-1, respectively, both p < 0.05). CONCLUSIONS: These data indicate that increased smooth muscle cell proliferation contributes to coronary restenosis in humans and support the concept that the extracellular matrix synthesis of adult smooth muscle cells is important to lesion formation.

Cell Division