Impact of hyperthyroidism and its correction on vascular reactivity in humans.

BACKGROUND: Although thyroid hormone (TH) exerts relevant effects on the cardiovascular system, it is unknown whether TH also regulates vascular reactivity in humans. Methods and Results- We studied 8 patients with hyperthyroidism, basally (H) and 6 months after euthyroidism was restored by methimazole (EU). Thirteen healthy subjects served as control subjects (C). We measured forearm blood flow (FBF) by strain-gauge plethysmography during intrabrachial graded infusion of acetylcholine, sodium nitroprusside (SNP), norepinephrine, and L-NMMA (inhibitor of NO synthesis). Basal FBF (in mL. dL(-1). min(-1)) was markedly higher in H than in C (5.8+/-1.2 and 1.9+/-0.1, respectively; P<0.001) and was close to normal in EU (2.6+/-0.3, P<0.01 versus H). During acetylcholine infusion, FBF increased much more in H (+33+/-5) than in C (+14+/-3, P<0.01 versus H) and in EU (+20+/-5, P=0.01 versus H and P=NS versus C). In contrast, the response to SNP infusion was comparable in the patients and control subjects. During norepinephrine infusion, the fall in FBF was much more pronounced in H (-6+/-1) than in C (-0.7+/-0.3, P<0.005 versus H) and in EU (-1.5+/-0.3, P<0.01 versus H). Finally, inhibition of NO synthesis by L-NMMA decreased FBF by 2.8+/-0.6, 0.61+/-0.7, and 1.4+/-0.3 in H, C, and EU, respectively (H versus C and EU, P<0.05). CONCLUSIONS: In hyperthyroidism, (1) the marked basal vasodilation is largely accounted for by excessive endothelial NO production, (2) vascular reactivity is exaggerated because of enhanced sensitivity of the endothelial component, (3) the vasoconstrictory response to norepinephrine is potentiated, and (4) this abnormal vascular profile is corrected when euthyroidism is restored by medical therapy. The data demonstrate that vascular endothelium is a specific target of TH.

Acetylcholine↗

Fluorescence imaging during photodynamic therapy of experimental tumors in mice sensitized with disulfonated aluminum phthalocyanine.

A fluorescence imaging system was used to monitor the emission of disulfonated aluminum phthalocyanine (AlS2Pc) during the photodynamic therapy (PDT) of murine tumors. Cells of the MS-2 fibrosarcoma were injected in mice in two compartments in order to cause the development of tumors in different host tissues. Two drug doses and two uptake times were considered. Moreover, the fluorescence of the AlS2Pc was excited using two wavelengths on the opposite sides of the absorption peak to detect a possible change in the absorption spectrum of the sensitizer induced by the PDT. In the tumors, the treatment induces a variation of the fluorescence intensity: in some mice a mild photobleaching takes place, in others a fluorescence enhancement occurs. Which effect predominates depends on the experimental conditions, even though a large spread of data was found amongst mice of the same group. In all mice, independently of the drug dose, uptake time or tumor compartment, a marked increase in the fluorescence signal takes place at the borders of the irradiated area. To quantify this effect we evaluated the ratio between the fluorescence intensities in the peritumoral area and in the tumor itself. This ratio increases monotonically during the PDT, showing a different behavior with the two excitation wavelengths. This indicates that the AlS2Pc absorption spectrum shifts toward shorter wavelengths as a result of the irradiation.

Animals↗

[Examples of intervention in cases of electromagnetic pollution in research laboratories].

Two examples of technical measures taken to reduce levels of radiofrequency electromagnetic radiation in research laboratories are reported. The first intervention was aimed at avoiding undue exposure of operators. The case is of interest because of the special exposure conditions, which are not as well characterized as in industrial applications, and require ad hoc analyses, measurements, and mitigation actions. As shown by the second example, such actions also allow effective screening of experimental apparatuses, which is of special importance when high sensitivities are required.

Equipment Design↗

[An experimental device for measuring the characteristics of echographic emissions].

An experimental system for the evaluation of the parameters characterizing the acoustic power emission of echographs is described. The apparatus is based on a commercial device, which has been modified to allow the analysis of different echographic probes, particularly used for diagnosis. The modified instrument is quite versatile in use and is suitable for the examination of virtually any kind of probe.