High efficiency, high quality x-ray optic based on ellipsoidally bent highly oriented pyrolytic graphite crystal for ultrafast x-ray diffraction experiments.

By the use of a thin highly oriented pyrolytic graphite crystal (HOPG) bent to a high-performance ellipsoidal shape it was possible to focus monochromatic x-rays of 4.5 keV photon energy with an efficiency of 0.0033, which is 30 times larger than for previously used bent crystals. Isotropic Ti K alpha radiation of a 150 microm source was focused onto a 450 microm spot. The size of the focal spot can be explained by broadening due to the mosaic crystal rocking curve. The rocking curve width (FWHM) of the thin graphite foil was determined to 0.11 degrees. The estimated temporal broadening of an ultrashort K alpha pulse by the crystal is not larger than 300 fs. These properties make the x-ray optic very attractive for ultrafast time-resolved x-ray measurements.

Journal Article↗

Near monochromatic X-rays for digital slot-scan mammography: initial findings.

X-ray spectra are composed of a broad bremsspectrum and anode-characteristic emission lines. In mammography typically molybdenum (Mo), rhodium (Rh) or tungsten (W) anodes are used in combination with Mo, Rh or aluminium filters. Only the photons with energies between 17 and 22 keV of the resulting spectrum are suitable for the soft tissue imaging needed for mammography. The aim of this article is to present first results obtained with a monochromator module mounted at the exit of the X-ray tube of a conventional clinical mammography unit. The experimental setup consists of a Siemens Mammomat 300, an X-ray monochromator module and a linear array detector for image acquisition. The technique is similar to the slot-scan technique known from digital mammography. The experimental machine allows to obtain images both with polychromatic and monochromatic X-rays. Initial evaluation of the system was performed by examination of a contrast-detail phantom (CD-MAM-phantom, Nijmegen, The Netherlands). Images done with the new monochromatic technique were compared to images of the phantom done with polychromatic spectra, with film-screen mammography as well as with digital mammography. The new technique with monochromatic slot-scan mammography resulted in correct identification of 93% of the phantom. Digital slot-scan mammography with polychromatic beam resulted in correct identification of 87%, digital full-field mammography in 83% and conventional film-screen mammography in 70% of the phantom. The results suggest that monochromatization has a potential for improving image quality or decreasing dose in X-ray mammography.

Equipment Design↗

Therapeutical effect of modified adamantane copolymer compounds: study of molecular mechanisms.

Copolymers of N-polyvinylpyrrolidone-acrylic acid (AB-1) and adamantane derivatives are known to possess marked antiviral activity in in vitro and in ovo models. Among the constructed preparations of AB-1 modified by adamantane derivatives some, especially AB-4 (modified by deitiforin), were found to show more extended antiviral activity and to inhibit markedly virus reproduction in susceptible permissive cell cultures and chicken embryos. In AB-4 treated cells and allantoic sacs, virus titers (influenza virus, herpes virus, and HIV) and virus antigen concentration were decreased. On the other hand, herpes virus-specific thymidine kinase and of DNA-polymerases isolated from Escherichia coli, Plectonema boryanum, and herpes virus type 1 infected murine brain tissue retained their activity after incubation with AB-4 or AB-2. The compounds investigated, in view of their effect on virus reproduction, are thought to be prospective as antiviral agents.

Adamantane↗