Hemodynamic performance evaluation of small aortic ATS Medical valves by Doppler echocardiography.

BACKGROUND AND AIMS OF THE STUDY: The ATS Medical valve was first implanted in 1992. The purpose of this report was to establish the normal range of each hemodynamic parameter, measured by Doppler echocardiography, in small aortic ATS Medical valves. METHODS: Twenty-five patients with small aortic ATS Medical valves, operated on over six months, and with no cardiac or prosthetic dysfunction, in sinus rhythm, on adequate oral anticoagulant therapy, and no other valve prosthesis or significant valvulopathy, were reviewed on the basis of physical examination and transthoracic Doppler echocardiography. RESULTS: For the aortic 21 Standard ATS Medical valve (n = 10), the following values were registered: peak velocity 2.40 +/- 0.39 m/s; peak gradient 23.7 +/- 6.8 mmHg; mean gradient 12.6 +/- 4.0 mmHg; valve effective orifice area 1.73 +/- 0.41 cm2; Doppler velocity index 0.47 +/- 0.11. For the aortic 19 Standard ATS Medical valve (n = 9), these values were: 3.41 +/- 0.43 m/s; 47.0 +/- 12.6 mmHg; 26.2 +/- 7.9 mmHg; 0.96 +/- 0.18 cm2; and 0.32 +/- 0.06, respectively. For the aortic 16 AP ATS Medical valve (n = 6), these parameters were 3.44 +/- 0.47 m/s; 47.7 +/- 12.0 mmHg; 27.0 +/- 7.3 mmHg; 0.61 +/- 0.09 cm2; and 0.30 +/- 0.04, respectively. CONCLUSIONS: Using Doppler echocardiography, the present study establishes the normal range of parameters which define the hemodynamic performance of the aortic 21 and 19 Standard and 16 AP ATS Medical valves, and demonstrates satisfactory hemodynamic performance of the aortic 21 and 19 Standard ATS Medical valves. It should be noted that the valve effective orifice area determined for the aortic 16 AP ATS Medical valve was smaller than that for the aortic 19 Standard ATS Medical valve, though these two prostheses have the same physical orifice area.

Adult↗

Mechanical cardiac valve thrombosis. Is thrombectomy justified?

To determine the incidence and results of the treatment offered to acute thrombotic obstructions of mechanical valvular prostheses, we have reviewed a series of 3,637 consecutive hospital survivors who, between January 1970 and September 1990, underwent single mitral or aortic and double mitroaortic valve replacements (MVR, AVR, and DVR, respectively). The cumulative follow-up in these patients was 22,783 years (mean, 7.2 years; range, 0.6-19 years). Sixty-five patients (24 MVR, 13 AVR, and 28 DVR) experienced 72 thrombotic prosthetic obstructions (42 mitral and 41 aortic prostheses) at a mean interval of 3.4 years (range, 0.6-14 years) after the operation. The actuarial prosthetic thrombosis free estimates were 96 +/- 0.9% for MVR, 97 +/- 0.9% for AVR, and 96 +/- 0.8% for DVR (all NS). Mortality associated with prosthetic thrombosis was 25% (four in the MVR group, five in the AVR group, and seven in the DVR group). Fifty-seven patients (22 MVR, 12 AVR, and 23 DVR) underwent a total of 62 reoperations, with a hospital mortality of 17% (two MVR, four AVR, and four DVR). In 37 of the latter patients (20 MVR, three AVR, and 14 DVR), we performed valve replacement (31 mitral prostheses and 14 aortic prostheses), with a hospital mortality of 16% (six of 37) and only one case of subsequent rethrombosis (actuarial rethrombosis free estimate, 96 +/- 3.6%). Conversely, five of the 27 patients (actuarial rethrombosis free estimate, 41 +/- 20%) (two MVR, 11 AVR, and 14 DVR) (seven mitral prostheses and 21 aortic prostheses) whose prosthetic valves were debrided developed rethrombosis during follow-up (p = 0.01).(ABSTRACT TRUNCATED AT 250 WORDS)

Actuarial Analysis↗

Reoperations for left-sided low-profile mechanical prosthetic obstructions.

A series of 2,474 hospital survivors of primary mitral, aortic, and double mitral-aortic valve replacement were observed for a cumulative period of 11.945 years (mean, 4.2 years; range, 0.6-14 years). The linearized incidences of reoperations for thrombotic obstructions were 0.33 +/- 0.08% for mitral valve replacement, 0.36 +/- 0.1% for aortic valve replacement, and 0.42 +/- 0.1% for double valve replacement (p = not significant). Forty-one patients (16 mitral, 12 aortic, and 13 double valve replacements) underwent a total of 44 reoperations with a mean interval of 36 +/- 29 months (range, 0.25-85 months) between operations. Diagnosis was established invasively only in 13 patients (30%). Hospital mortality at reoperation was 18% (8 patients); 28 patients (63%) required emergency surgery. The choice surgical procedures were thrombectomy for clotted aortic prostheses (18 of 24) and valve replacement for obstructed mitral valves (22 of 25; p less than .001). Rethrombosis occurred in 3 patients (1 aortic and 2 double valve replacements). At hospital admission 17 patients (38%) had prothrombin times outside therapeutic ranges (between 20 to 30% of the normal value). The incidence of reoperations for thrombosis in low-profile mechanical prostheses was unaffected by valvar position and number of prostheses implanted. Rethrombosis occurred only in previously cleaned valves, although its occurrence was not significant. The present results indicate that, as experience is gained in the diagnosis and surgical management of this complication, hospital mortality can be reduced significantly (from 37% to 4%).

Aortic Valve↗

Surgical treatment of active prosthetic valve endocarditis. Results in 66 patients.

The results of combined medical and surgical management of 66 patients with active prosthetic valve endocarditis (APVE) are analyzed. Between 1970 and 1985, 3510 patients were operative survivors of mitral, aortic or double mitral-aortic valve replacement. Cumulative follow-up was 15,640 patient-years (mean 4.4 years). The overall annual incidence of reoperation for APVE was 0.42 +/- 0.05% (0.34 +/- 0.08% for biological and 0.46 +/- 0.06% for mechanical prostheses, p = n.s.). Early APVE occurred in 21 patients and 45 patients had late APVE. Indications for surgery were heart failure in 92%, systemic emboli in 5% and persistent sepsis in 3% of patients. Overall operative mortality (less than 30 days) was 38% (25/66). (Early APVE 52% and late APVE 31%). Anatomical location, valve design and number of prostheses implanted did not correlate with a higher operative risk. Overall endocarditis-related mortality was 56% (37/66). Uni and multivariate stepwise logistic regression analysis identified: 1) date of surgery (p = 0.01), 2) renal failure (p = 0.03) and 3) early APVE (p = 0.03) as predictors of endocarditis-related death. Actuarial survival at 1, 5 and 10 postoperative years was 41 +/- 6%, 30 +/- 6% and 24 +/- 7% respectively. This study confirms the high lethality of APVE. However, with adequate and aggressive combined medical and surgical management, some patients can be saved.

Adult↗

Comparative clinical results with Omniscience (STM1), Medtronic-Hall, and Björk-Shiley convexo-concave (70 degrees) prostheses in mitral valve replacement.

The intermediate clinical results of 289 patients undergoing isolated mitral valve replacement with three different low-profile mechanical prostheses have been retrospectively analyzed and compared. Between June, 1980, and September, 1983, 70 patients received the Omniscience prosthesis, 159 patients the Medtronic-Hall valve, and 60 patients the convexo-concave 70 degree Björk-Shiley prosthesis. Hospital mortality was 15% for the Björk-Shiley group, 4.4% for the Medtronic-Hall group, and 7.1% for the Omniscience group. Cumulative follow-up was 88 years (mean 1.7 years) for the Björk-Shiley, 229 years (mean 1.5 years) for the Medtronic-Hall, and 223 years (mean 3.3 years) for the Omniscience group. All patients were placed on a program of anticoagulant therapy (dicumarol) postoperatively. Actuarial survival rates (+/-SE) 2 years postoperatively were comparable for the three groups: Björk-Shiley, 90% +/- 4.7%; Medtronic-Hall, 93% +/- 2.2%; and Omniscience, 88% +/- 4.1% (p = NS). Late mortality, expressed at linearized rates (percent patient-year +/-SE), was 3.4% +/- 1.9% for the Björk-Shiley group, 1.7% +/- 0.8% for the Medtronic-Hall group, and 3.6% +/- 1.2% for the Omniscience group (p = NS). Actuarially determined rates of freedom from thromboembolic complications (systemic embolism and valvular thrombosis) 2 years postoperatively were 97% +/- 2.2% for the Björk-Shiley group, 94% +/- 2.1% for the Medtronic-Hall, and 84% +/- 4.7% for the Omniscience group (p = 0.05, Omniscience versus Medtronic-Hall; p = 0.02, Omniscience versus Björk-Shiley) The actuarial probability of being free from reoperation 2 years postoperatively was 92 +/- 3.5 for the Björk-Shiley group, 92 +/- 2.9 for the Medtronic-Hall group, and 82 +/- 3.9 for the Omniscience group (p = 0.04). The major cause for reoperation in the Omniscience group was valve thrombosis (seven patients), yielding a linearized incidence (+/-SE) of 3.1 +/- 1.1 (p = 0.01). No statistically significant differences were obtained regarding the incidence of prosthetic infective endocarditis or perivalvular leak. Overall rates of anticoagulant-related hemorrhage were comparable for the three groups.

Actuarial Analysis↗

Long-term comparative analysis of the Björk-Shiley and Hancock valves implanted in 1975.

The long-term results in all patients undergoing isolated mitral, aortic, or double mitral-aortic heart valve replacement operated upon in 1975 has been retrospectively analyzed. A total of 153 patients received the standard Björk-Shiley (flat pyrolytic disc) mechanical prostheses and 150 patients received the noncomposite Hancock porcine xenograft. Overall operative mortality was not significantly different between groups. All patients receiving a Björk-Shiley prosthesis, but none in the Hancock group, received long-term anticoagulant therapy. Medium and long-term actuarial survival rates (5 and 10 years postoperatively) were comparable for the two groups (88% for Björk-Shiley and 84% for Hancock [NS] at 5 years; 86% for Björk-Shiley and 80% for Hancock at 10 years [NS]). The incidence of systemic embolism was similar in the two groups (1.6% +/- 0.4% per patient-year for the Björk-Shiley group and 1.3% +/- 0.3% per patient-year for the Hancock group [NS]). Also the incidence of endocarditis was similar (0.6% +/- 0.2% per patient-year for the Björk-Shiley group and 0.8% +/- 0.3% per patient-year for the Hancock group [NS]). In the Hancock group the overall incidence of reoperations was significantly higher than in the Björk-Shiley group (4.2% +/- 0.6% per patient-year versus 0.9% +/- 0.3% per patient-year (p = 0.001). The major cause for reoperation in the Hancock group was primary tissue failure (3% +/- 0.5% per patient-year). In the Björk-Shiley group the major cause of reoperation was valve thrombosis (0.5% +/- 0.2% per patient-year). Therefore, accepting the fact that other bioprostheses may behave differently from the Hancock noncomposite xenograft, we currently restrict our indications for valve replacement with bioprostheses.

Actuarial Analysis↗

Early surgical results of the Medtronic-Hall valve.

A clinical trial with the Medtronic-Hall (M-H) valve was started in November 1981. From then until December 1982, 157 patients underwent heart valve replacement: Mitral valve replacement (MVR) 63 patients, isolated aortic valve replacement (MVR) 41 patients, and 53 underwent combined mitral-aortic valve replacement (MVR + AVR). Hospital mortality was 2.5% overall (4/157). The total follow-up was 147 patient-years (range 1 to 12 months). Late mortality was 3.2% for MVR, 2.5% for AVR and 1.9% for double MVR + AVR. Oral anticoagulation therapy (Dicumarol) was administered to all patients included in this study. There were no anticoagulant complications and no prosthetic bacterial endocarditis registered in this series of patients up to date. The incidence of systemic embolism was 2.5 events per 100 patient-years in the AVR group. No embolic episodes have been registered in the other 2 groups. The incidence of valvular dysfunction (expressed as events per 100 patient-years) were: --Perivalvular leak (0 MVR, 0 AVR and 2 MVR + AVR) --Valve thrombosis (1.7 MVR, 0 AVR and 0 MVR + AVR) --Mechanical dysfunction (1.7 MVR, 0 AVR and 0 MVR + AVR) Despite a short follow-up, the results with the Medtronic-Hall valve are encouraging and compare favorably with other mechanical prostheses.

Adult↗