Pressure support ventilation during fibreoptic intubation under propofol anaesthesia.

GOAL OF THE STUDY: To assess the benefit of pressure support ventilation during fibreoptic intubation performed under propofol anaesthesia in patients having an anticipated difficult intubation. PROCEDURES: Thirty-two patients with ENT cancer, and having at least two criteria for anticipated difficult intubation were prospectively included. All patients received topical lidocaine 2% and propofol by plasma target control infusion (initial target concentration 3 microg ml(-1), then adjusted to maintain loss of consciousness without apnoea). They were randomly assigned between two groups: spontaneous breathing (SB) or pressure support ventilation (with a support level set at 10 cm H(2)O) both using Fi(o(2))=1. Conditions for fibreoptic intubation, respiratory parameters (pulse oxymetry, ventilatory frequency, tidal volume and PetCO2 after intubation) and haemodynamic parameters were recorded. RESULTS: Patient characteristic data and intubation conditions were similar between both groups. All patients had a successful fibreoptic intubation and none needed a rescue procedure because of desaturation. In spite of a longer duration of intubation, PE'CO2 after intubation was lower and tidal volume during intubation was higher with pressure support ventilation than in SB patients [38.1 (4.2) vs 42.3 (4.7) mm Hg and 371 (139) vs 165 (98) ml, respectively]. Desaturation episodes were observed in two SB patients conversely to no episode during pressure support ventilation, probably because of the higher minute ventilation. CONCLUSION: Pressure support represents a useful method to improve ventilation during fibreoptic intubation under propofol anaesthesia in patients with an anticipated difficult intubation.

Aged↗

Fibre-optic intubation teaching in sedated patients with anticipated difficult intubation.

BACKGROUND AND OBJECTIVES: The objective of the study was to assess the safety of training fibre-optic intubation performed under propofol light general anaesthesia in patients with an anticipated difficult intubation. METHODS: Patients with ear, nose and throat cancer having at least two criteria for anticipated difficult intubation and scheduled for fibre-optic intubation were included prospectively. In 26 patients, intubation was performed by an anaesthesia resident (under senior supervision), whereas in 20 patients, it was performed by a senior anaesthesiologist. All patients received propofol light general anaesthesia adjusted to maintain both loss of consciousness and spontaneous ventilation. RESULTS: Of the 46 patients, 45 had successful fibre-optic intubation, and one needed a rescue procedure because of hypoxaemia. Residents failed to intubate four patients, who were easily intubated by the senior. Episodic hypoxaemia (SPO2 < 90%) occurred in three patients in each group. No statistically significant difference was found between junior and senior neither on the duration of the procedure (9.3 +/- 4.9 vs. 7.5 +/- 4.0 min) nor on the propofol consumption (197 +/- 130 vs. 193 +/- 103 mg) or the ETCO2 at the end of the procedure (36 +/- 6 vs. 38 +/- 6 mmHg), respectively. CONCLUSION: Teaching fibre-optic tracheal intubation in patients with anticipated difficult intubation and sedated with propofol did not increase morbidity significantly compared with an experienced anaesthesiologist. Fibre-optic intubation under propofol light general anaesthesia could be safely performed by a resident as long as a senior anaesthesiologist is permanently present, spontaneous ventilation is maintained and a rescue oxygenation technique is immediately available.

Airway Obstruction↗

Heated intra-operative intraperitoneal oxaliplatin plus irinotecan after complete resection of peritoneal carcinomatosis: pharmacokinetics, tissue distribution and tolerance.

BACKGROUND: The purpose of this study was to report the pharmacokinetics (PK) and tolerance profile of intraoperative intraperitoneal chemo-hyperthermia (IPCH) with oxaliplatin and irinotecan. PATIENTS AND METHODS: Thirty-nine patients with peritoneal carcinomatosis (PC) of either gastrointestinal or peritoneal origin underwent complete cytoreductive surgery followed by IPCH with a stable dose of oxaliplatin (460 mg/m(2)), plus one among seven escalating doses of irinotecan (from 300 to 700 mg/m(2)). IPCH was carried out with the abdomen open, for 30 min at 43 degrees C, with 2 l/m(2) of a 5% dextrose instillation in a closed continuous circuit. Patients received intravenous leucovorin (20 mg/m(2)) and 5-fluorouracil (400 mg/m(2)) just before IPCH to maximize the effect of oxaliplatin and irinotecan. RESULTS: Irinotecan concentration in tumoral tissue increased until 400 mg/m(2) and then remained stable despite dose escalations. It was 16-23 times higher than in non-bathed tissues. Increasing doses of intraperitoneal irinotecan did not modify the PK of intraperitoneal oxaliplatin, and the drug concentration ratio was 17.8 higher in tumoral tissue (bathed) than in non-bathed tissues. The hospital mortality rate was 2.5% and the non-hematological complication rate was 25%. However, grade 3-4 hematological toxicity rate was 58%. CONCLUSION: Intraperitoneal heated oxaliplatin (460 mg/m(2)) plus irinotecan (400 mg/m(2)) presented an advantageous PK profile and was tolerated by patients, despite a high hematological toxicity rate.

Adult↗

Desflurane-remifentanil-nitrous oxide anaesthesia for abdominal surgery: optimal concentrations and recovery features.

BACKGROUND: Intraoperative combinations of volatile and opioid agents are used to achieve unconsciousness, hypnotic sparing, haemodynamic stability and uneventful recovery. This study describes the influence of different remifentanil concentrations on these variables when combined with desflurane during abdominal surgery. METHODS: Sixty-one healthy adult patients were randomly allocated to one of five predefined remifentanil target concentrations (3, 5, 7, 10 or 15 ng ml(-1)). Anaesthesia was titrated to maintain mean blood pressure (MBP), heart rate (HR) and BIS trade mark within predetermined values by adjusting desflurane delivery. Postoperative analgesia using propacetamol and morphine was initiated 30-45 min before skin closure, and continued using morphine PCA. RESULTS: Desflurane requirements adjusted to both BIS and haemodynamics were not significantly modified by the remifentanil concentration (median Fet(DES) 2.7% before incision, 2.5% intraoperatively, and 2.2% during closure), resulting in a calculated drug consumption of 0.22-0.25 ml min(-1) (with 1.5 l min(-1) fresh gas flow). High remifentanil concentration decreased MBP and HR, and reduced the duration of tachycardia, but increased the duration of hypotension. The optimal balance was obtained with a remifentanil concentration of 5-7 ng ml(-1) for intubation, 3 ng ml(-1) until incision, 10 ng ml(-1) during intra-abdominal surgery and 5-7 ng ml(-1) during closure. Post-operative morphine requirements were not significantly modified by intraoperative remifentanil concentrations (median 30 mg/24 h, range [2-88]). CONCLUSION: Remifentanil target concentrations from 3 to 15 ng ml(-1) had little influence on desflurane requirements or postoperative morphine consumption, but markedly modified intraoperative haemodynamic stability, suggesting that the target concentration should closely follow the successive noxious stimulations.

Abdomen↗

[Survey and budgetary impact of anaesthesia machines failures].

OBJECTIVE: To assess the incidence and the causes of failures of anaesthesia machines in relation to aging. Study design. - Prospective survey from january 1996 to july 2000. MATERIAL AND METHODS: The causes (mechanical or electronic), the moment of identification (checklist, maintenance operation or quality-control operation) of each anaesthetic machine failure, the repair cost and the maintenance cost of 14 anaesthetic machines have been collected and entered into a database. RESULTS: Over 31,948 anaesthesia delivered during the period of the study, 614 failures have been declared: 53% were related both to mechanical problems or monitoring failure and 40% were identified during the pre-operative checklist. In half of the cases, a specially trained anaesthetic nurse was able to correct the failure in the operating theatre. The annual rate of anaesthetic machine failure remained stable over the study period and the annual maintenance cost is approximatively 10% of the initial machine value. No procedure was cancelled because of a machine technical failure. CONCLUSION: Anaesthetic machine failure rate change according to the time should not be criteria for remplacement if rigorous quality control and maintenance operation are used.

Anesthesia, Inhalation↗

Electrochemotherapy: a new treatment of solid tumors.

Electrochemotherapy is a new local treatment of the solid tumors that can be defined as the local potentiation, by means of permeabilizing electric pulses, of the antitumor activity of non-permeant (e.g. bleomycin) or low-permeant (e.g. cisplatin) anticancer drugs. The electric pulses are delivered locally on the solid tumors, after the intravenous or intralesional injection of the chemotherapy agent. In this review, the basis of the electrochemotherapy are recalled. Then, after summarizing clinical data, we present some results of the European project Cliniporator, as well as the new pulse generator, the Cliniporator, that incorporates new features resulting from this research project, and that is fully conceived for a clinical use. Finally, future perspectives are discussed.

Animals↗

Surgical management of posterior pharyngeal wall carcinomas: functional and oncologic results.

BACKGROUND: The optimal primary treatment for posterior pharyngeal wall tumors remains controversial. METHODS: To assess the relevance of surgical treatment from a functional and oncologic point of view, we reviewed the cases of 77 patients surgically treated between 1984 and 1995. Among them 23 had been previously irradiated. Fifty-five patients underwent a conservative surgery (CS) sparing the larynx; 19 direct closures, 6 reconstructions of the posterior wall with a thoracic myocutaneous flap, 15 with a platysma flap, and 15 with a free forearm flap were performed. Twenty-two patients underwent radical surgery (RS). All previously untreated patients had postoperative radiotherapy. The functional assessment concerned the CS group. Oncologic results, especially local control and survival were studied for the whole group. RESULTS: Of the 55 patients who underwent CS, 53 (96%) had their canula and 49 (89%) their feeding tube removed. At 1 year, in the platysma and free forearm groups, 21 of the 24 assessable patients were back to exclusive oral intake. For patients treated by primary surgery followed by radiotherapy, the rate of local failure was 11% (18% for tumors greater than 4 cm), and the 5-year survival rate was 35%. For patients who had previous radiotherapy, the rates were, respectively, 52% and 16%. CONCLUSION: The satisfactory functional results, caused by the improvement of reconstructive procedures, allow conservative surgery even in the case of large tumors. Oncologic results, especially local control, suggest that primary surgery followed by radiotherapy is effective for the treatment of posterior wall cancer. The oncologic results of surgery in a previously irradiated area are poor, and CS is not recommended in these cases.

Carcinoma, Squamous Cell↗

[Target controlled infusion (TCI) anesthesia using propofol. Assessment of training and practice in the operating room].

OBJECTIVE: To evaluate overall awareness of TCI and the need for training in the TCI technique. To assess, among trained anaesthetists, the value of the session and the impact of TCI technique on their working practice. STUDY DESIGN: Two prospective domestic surveys during the first quarter of 1999. METHODS: Three hundred anaesthetists representative of French anaesthetists as a whole, and 336 anaesthetists who had taken part in a training course. RESULTS: The notoriety of TCI was high and greater in the public sector compared with the private sector. Almost 3/4 of anaesthetists believed that training was necessary but only four anaesthetists out of ten TCI users said they had taken part in training sessions. After the training session nine anaesthetists out of ten became TCI users and would have recommended the training course despite the low number and variety of anaesthetic procedures observed during the practical part of training. The main difficulties reported during initial use were the choice of target concentrations and the management of drug interactions. Familiarisation to the technique was rapid (less than 20 procedures). Despite the lack of long experience (< 6 months for more than 2/3 of them), TCI appeared to be more likely used for anaesthesia of average duration. CONCLUSIONS: TCI was perceived to be an innovative concept with a requirement of a specific training. This preliminary appraisal of training sessions was generally satisfactory but underline a need for future training sessions focused on practical aspects.

Anesthesia, Intravenous↗

[Automatic analysis of electroencephalogram: what is its value in the year 2000 for monitoring anesthesia depth?].

Spontaneous EEG has been proposed for monitoring depth of anaesthesia and adjusting anesthetic drugs doses. This review describes the main features of spontaneous EEG, the principles of EEG signal analysis used in anaesthesia, and the EEG effects of the different anesthetic drugs in adults and children. Then, the correlations between EEG parameters changes and clinical signs of anesthesia (loss of consciousness and memory, lack of movement and haemodynamic stability despite noxious stimulations) are analyzed. The best signal analysis technique available today for routine use seems to be bispectral analysis, which returns, in the available monitors, a single number called bispectral index or BIS. Based upon the recent literature, clinical uses, performances and limits of use of BIS are described and discussed.

Anesthesia↗

Haemodynamic changes and vasopressin release are not consistently associated with carbon dioxide pneumoperitoneum in humans.

BACKGROUND: Conflicting haemodynamic changes, suggested to be caused by vasopressin release, have been reported during carbon dioxide (CO2) pneumoperitoneum. However, peritoneal stimulations including open surgery cause both a systemic vasopressor response and a vasopressin release, which are suppressed by opiate administration. Also, a decreased venous return of blood to the heart causes vasopressin release. Furthermore, previous haemodynamic assessments of laparoscopic surgery have been conducted using various anaesthetic regimens, which are likely to have caused various haemodynamic effects. We hypothesised that intraoperative haemodynamic and/or humoral changes would not be observed in association with laparoscopic surgery provided that, (a) normovolaemia is continuously maintained using transoesophageal echocardiographic (TEE) assessment, and (b) adequate depth of general anaesthesia is continuously maintained by bispectral index (BIS) monitoring and high plasma Ievel opiate administration. METHODS: Twenty ASA 1 women undergoing laparoscopic surgery received 10 ml. kg-1 lactated Ringer's solution and thereafter were randomly allocated to receive intraoperatively either 8 ng. ml-1 or 4 ng. ml-1 plasma remifentanil concentrations while BIS was maintained at 50+/-5 by isoflurane alteration. The group receiving 4 ng. ml-1 remifentanil was used as control. Expired CO2 was maintained within a 32-38 kPa range throughout the investigation. Complete TEE haemodynamic investigation was performed before pneumoperitoneum (PP) (T1), and during PP horizontal (T2), with a head-up tilt (T3), with a head-down tilt (T4), horizontal (T5), and PP released (T6). Plasma vasopressin, epinephrine and norepinephrine levels were measured at T1, T3, and T6. ANOVA, Student's t-test and Mann-Whitney U-test were used for statistical analysis. RESULTS: Haemodynamic indices and humoral values did not change significantly within and between remifentanil groups throughout the investigation (all P<0.05). CONCLUSION: Continuous adequate depth of anaesthesia and normovolaemia may have prevented both a humoral and a haemodynamic response, initiated in the peritoneum by the contact with CO2 in previous investigations.

Adult↗

[Perianesthetic management of carcinoid syndrome: contribution of the bispectral EEG index].

This case report described the perioperative management of a patient undergoing laparotomy for ileal carcinoid tumor with liver metastases and preoperative carcinoid syndrome. During surgery, bispectral index monitoring, combined with classical blood pressure and heart rate, allowed to discriminate hypertension related to the carcinoid syndrome, from hypertension reflecting an inadequate level of anaesthesia. Consequently, adequate treatment by a somastotatin analogue could be early administered.

Adjuvants, Anesthesia↗

[The value of monitoring the bispectral index of the EEG for the management of hypertension during laparoscopic surgery].

OBJECTIVE: Assessment of the usefulness of Bispectral Index of the EEG (BIS) for the management of hypertension during laparoscopic surgery. STUDY DESIGN: Preliminary, non-randomized study. PATIENTS: 15 patients undergoing laparoscopic surgery. METHODS: Anaesthesia by TCI of propofol and boluses of fentanyl in order to maintain fentanyl effect site concentration above 2 ng.mL-1 according to Scott kinetics model. Mean arterial pressure (MAP), heart rate (HR) and BIS were recorded. BIS values between 40 and 60 and MAP between 80 to 120% of preinduction values were maintained using a Gurman like decision matrix. RESULTS: MAP rose significantly after insufflation while variations of HR and BIS were not significant. DISCUSSION: During laparoscopy, factors other than pain can be responsible for hypertension. Nevertheless in clinical practice, inadequate anaesthesia should be ruled out before considering other mechanisms for hypertension. In this study, hypnosis remained adequate with a BIS under 60, and analgesia was considered sufficient as demonstrated by a good stability of the BIS despite nociceptive stimuli. This suggests that more specific haemodynamic factors were responsible for the observed rise in arterial pressure. CONCLUSION: Associating BIS monitoring and MAP in a modified Gurman decision matrix may allow more judicious therapeutic choices for hypertension during laparoscopic surgery.

Anesthetics, Intravenous↗

[Perioperative autotransfusion with salvage blood in cancer surgery] .

OBJECTIVES: Intraoperative blood cells salvage using a Cell Saver technique is controversial in oncologic surgery because tumor cells could be aspirated and reinfused to the patient. The goal of this review was to discuss the risk associated with this technique, and the way to minimize it. DATA SOURCES: A review of the literature has been made by questioning PubMed site (http://nbci.nlm.nih.gov) on the period of 1968 to 2000. The key words were: intraoperative blood salvage, blood transfusion, autologous, cancer. Cases reports have been excluded. STUDY SELECTION: Tumor cells aspirated and reinfused have been numbered in both experimental and clinical studies. In clinical studies, the outcome after intraoperative cells salvage/reinfusion has been compared to published data or historical groups of allogeneic transfusion, all in non randomized studies. DATA SYNTHESIS: Both experimental and clinical studies confirmed the presence of cancer cells in the blood either aspirated or reinfused. However, six clinical studies with limited number of patients did not show metastatic spread associated with Cell Saver. The addition of leukocyte filters reduces greatly this quantity of cancer cells. Irradiation of the pack did not destroy tumor cells but blocked their proliferative capacity. In the other hand, some infiltrative tumors were shown to have permanent cancer cells seeding, quantitatively superior to the seeding observed when a Cell Saver is used. CONCLUSION: It seems reasonable to use the Cell Saver in oncologic surgery, if possible with a leukocyte filter, not only in case of unexpected major bleeding (consensus), but also in programmed cases with high risk of huge hemorrhage.

Blood Transfusion, Autologous↗

[The breakdown of anesthesia equipment survey].

OBJECTIVE: To assess the incidence and the causes of failures of anaesthesia machines. STUDY DESIGN: Prospective survey from August 1995 to September 1997. MATERIAL: Check-list and machine failure forms. METHODS: Failures of anaesthetic machines have been collected and entered into a database. Causes and treatment of each failure have been analysed. RESULTS: Of 5,096 foreseen forms, 3,926 (77%) have been completed after check-list or anaesthesia machine failure. Overall, 233 incidents have been declared (4.5%). Failures identified during the preoperative check-list (n = 96) were mainly related to mechanical problems, especially the gas proportioning device (35%). Perioperative failures (n = 137) were mostly related to electronic problems (ventilator: 27% and monitor: 57%). In more than half of the cases, a specially trained anaesthetic nurse was able to correct the failure in the operating theatre. Using 14 anaesthetic machines for 12 operating rooms, no procedure was cancelled because of a technical failure of a machine. CONCLUSIONS: This study emphasizes the value of the check-list and the failure report. The presence of a specially trained anaesthetic nurse allows immediate correction of the majority of technical problems.

Anesthesiology↗

[Sufentanil in balanced anesthesia: need to predict concentrations for dose optimization].

During balanced anaesthesia sufentanil may be difficult to use, as the required doses change over time depending on the patient and the noxious stimuli. Patient adjustment may be improved by using pharmacokinetic simulations that predict the concentration achieved in the body. In the first case report, sufentanil was given manually as repeated boluses, then by infusion. As haemodynamic status remained unstable, a simulation of the sufentanil concentration time course was started during the case. It showed that instability had pharmacokinetic explanation and allowed to determine the adequate sufentanil concentrations (0.30-0.40 ng.mL-1 + N2O + isoflurane 0.8-1 vol% for abdominal surgery). However, adjusting the doses manually required numerous human actions. In the second case, sufentanil was given as a computer-controlled infusion. The adequate concentrations were determined (0.15-0.20 ng.mL-1 + N2O + isoflurane 0.4 vol% for peripheral surgery in an aged cardiac patient). They were maintained with a limited number of human actions and resulted in satisfactory haemodynamic stability.