Quantitative planar imaging with technetium-99m methoxyisobutyl isonitrile: comparison of uptake patterns with thallium-201.

To compare the myocardial uptake pattern of 99mTc-labeled methoxyisobutyl isonitrile [( 99mTc] MIBI) and 201TI, planar scintigraphy were performed in both patients with documented coronary artery disease and subjects with a low likelihood of disease. Quantitative analysis was employed using a standard interpolative background subtraction algorithm and a new algorithm modified to better accommodate for the differences in extracardiac activity seen with [99mTc]MIBI rest images. Among patients with coronary artery disease, the standard algorithm yielded no significant difference in relative defect magnitude between [99mTc]MIBI and 201TI on stress scintigrams (p = 0.48), although the magnitude of [99mTc]MIBI defects was greater on resting images (p = 0.02). When the modified algorithm was employed, defect magnitude was similar for both stress (p = 0.91) and rest (p = 0.20) images. Normal segmental uptake ratios derived from a comparison of contralateral segments (e.g., septal:posterolateral) in the low likelihood patients were similar for both [99mTc]MIBI and 201TI. Thus, modification of the standard interpolative background subtraction algorithm is necessary for quantitative planar [99mTc]MIBI perfusion imaging. When appropriate background subtraction is employed, myocardial uptake and quantitative defect magnitude of [99mTc]MIBI and 201TI planar images are similar.

Adult

Component resolution indices for scintillation camera systems.

From published overall resolution indices for three Anger camera systems, measured with three straight-bore collimators and 99mTc in air and with a water absorber present, the components due to inherent camera resolution, collimator geometry, and scatter are derived at various depths. Replacement of S-11 multiplier phototubes by bialkali phototubes improves calculated inherent Pho/Gamma III camera resolution by about 30% and by a further 33% upgrading to a high-performance model. At distances 2, 5, 8, and 10 cm from each collimator face with an intervening water absorber, mean scatter components of overall resolution indices are 6, 8, 9, and 10 mm, respectively. In typical clinical 99mm Tc imaging situations with a scattering medium present, the relative contributions of camera, collimator, and scatter to the total overall system resolution are presented.

Radionuclide Imaging