PubMed Health⌕ Search

Biomedical subjects

V Camomilla

Publications and source records attributed to V Camomilla.

3 recordsLinked to original sources

Femoral anatomical frame: assessment of various definitions.

The reliability of the estimate of joint kinematic variables and the relevant functional interpretation are affected by the uncertainty with which bony anatomical landmarks and underlying bony segment anatomical frames are determined. When a stereo-photogrammetric system is used for in vivo studies, minimising and compensating for this uncertainty is crucial. This paper deals with the propagation of the errors associated with the location of both internal and palpable femoral anatomical landmarks to the estimation of the orientation of the femoral anatomical frame and to the knee joint angles during movement. Given eight anatomical landmarks, and the precision with which they can be identified experimentally, 12 different rules were defined for the construction of the anatomical frame and submitted to comparative assessment. Results showed that using more than three landmarks allows for more repeatable anatomical frame orientation and knee joint kinematics estimation. Novel rules are proposed that use optimization algorithms. On the average, the femoral frame orientation dispersion had a standard deviation of 2, 2.5 and 1.5 degrees for the frontal, transverse, and sagittal plane, respectively. However, a proper choice of the relevant construction rule allowed for a reduction of these inaccuracies in selected planes to 1 degrees rms. The dispersion of the knee adduction-abduction and internal-external rotation angles could also be limited to 1 degrees rms irrespective of the flexion angle value.

Algorithms↗

The sensitivity of posturographic parameters to acquisition settings.

The objective of this study was to evaluate the sensitivity of posturographic parameters (PP) to changes in acquisition settings. A group of eight young adults underwent a set of typical orthostatic posture trials, and selected PP were then calculated from a set of centre of pressure (CoP) displacement time series obtained by applying different cut-off frequencies to the same set of raw data. Four PP out of 11 showed significant changes with respect to cut-off frequency. Statistical mechanics parameters exhibited smaller sensitivity than summary measures. On the basis of the results obtained, a proposal for a standard cut-off frequency and a sampling rate value is embodied in the paper together with some suggestions on measurement settings, with a view to standardized use of instrumentation for quantitative analysis in orthostatic posturography.

Acceleration↗

Hemodynamics as a possible internal mechanical disturbance to balance.

The postural control system is assessed by observing body sway while the subject involved aims at maintaining a specified up-right posture. Internal masses generate internal reaction forces that constitute an internal mechanical stimulus that may contribute to cause segmental displacements, i.e. body sway. Thus, gaining knowledge about the amplitude and direction of these reaction forces would contribute to gain insights into the mechanisms that influence the maintenance of balance and into its control. The 3-D force vector that acts on the body centre of mass (COM) and is associated with the transient blood movement at each cardiac cycle was assessed in a population sample of 20 young adults during the maintenance of a quiet up-right posture. Typical patterns of the three components of this force vector were identified. Relevant parameters were selected and submitted to sample statistics. For a number of them, linear correlation with subject-specific parameters was found. The antero-posterior force component was characterised by a triphasic major wave, the peaks of which had values up to 0.40 N. The vertical component showed a repeatable triphasic wave with peak-to-peak values in the range 1.3-3.0 N. The medio-lateral component showed relatively low peak-to-peak values (in the range 0.05-0.10 N). The resultant vector had an amplitude that underwent several oscillations during the cardiac cycle and reached its maximal value in the range 0.6-1.7 N.

Adaptation, Physiological↗