PubMed Health⌕ Search

Biomedical subjects

V Concha-Herrera

Publications and source records attributed to V Concha-Herrera.

2 recordsLinked to original sources

Robust interpretive optimisation in high-performance liquid chromatography considering uncertainties in peak position.

In the context of interpretive chromatographic optimisation, robustness is usually calculated by introducing deliberated shifts in the nominal optimal conditions and evaluating their effects on the monitored objective function, mimicking thus the experimental procedures used in method validation. However, such strategy ignores a major source of error: the uncertainties associated to the modelling step, that may give rise to deceiving results when conditions that were expected to yield baseline separation are reproduced in the chromatograph. Two approaches, based on the peak purity concept, are here proposed to evaluate the robustness of the objective function under the perspective of measurement errors and modelling. The first approach implements these uncertainties as an extra band broadening for each chromatographic peak. The second one implements them as peak fluctuations in simulated replicated assays, which gives rise to a distribution of peak purities, easily computed through Monte-Carlo simulations. Both approaches predict satisfactorily a decreased separation capability, with respect to the conventional approach, for those situations where the uncertainties in peak position make the objective function critical. The first approach is less optimistic and formally less rigorous than the second one, but its computation is simpler. It can be used to map the critical resolution regions, to be comprehensively appraised further by the slower, although more rigorous, Monte-Carlo approach.

Amino Acids↗

Limits of multi-linear gradient optimisation in reversed-phase liquid chromatography.

The concept of limiting peak purity was applied to quantify the degree of completion of the separation capability of a chromatographic system using multi-linear gradients. The objective was to check whether the complexity of a gradient program deserves be increased to enhance resolution by inserting more linear segments, or on the contrary, no significant improvements can be expected under more complex gradients. A set of 19 isoindole derivatives of primary amino acids was selected to test the performance of isocratic, single linear and multi-linear gradients. Accurate simulated chromatograms were obtained via numerical integration of the general equation of gradient elution, using pre-established start and end conditions of the gradient program. The overall peak purity was selected as objective function. Good--although not baseline--resolution was achieved with an optimal trilinear gradient. Excellent agreement between experimental and predicted optimal chromatograms was found. With the proposed approach, a degree of completion of the separation capability of the chromatographic system of 21.2, 49.7, 81.5 and 88.5% was accomplished with optimal gradients with one, two, three and four segments, respectively. More complex gradients did not enhance the latter figure significantly. Also, multi-linear gradients gave rise to more benefits than complementary gradients.

Chromatography, Liquid↗