PubMed Health⌕ Search

Biomedical subjects

V Dobson

Publications and source records attributed to V Dobson.

At least 91 records · Page 5Linked to original sources

Visual acuity in infants--the effect of variations in stimulus luminance within the photopic range.

The forced-choice preferential looking technique was used to measure 2-month-old infants' visual acuity for black-and-white, square-wave gratings at six luminance values between -1.0 and 3.0 log cd/m2. The results indicated that the infants' acuity was relatively unaffected by variations in luminance above 1 log cd/m2, but was reduced by approximately 1 octave at a luminance of -0.8 log cd/m2. These results are in agreement with the results of adults tested in the same apparatus and with previously published data from adult subjects. Our results suggest that for infants, as for adults, variations in room illumination above 1.0 log cd/m2 have little effect on visual acuity.

Adult↗

The retina of the newborn human infant.

We have examined a pair of eyes from a normal, full-term infant who died at 8 days as a result of accidental injury. Eyes were obtained immediately after death, fixed, and sectioned for light microscopy. Results from both eyes were substantially the same. The macular region was still drastically immature at 1 week. Even though a foveal depression existed, all cell layers were still present across it. Furthermore, the inner nuclear layer was divided into two separate layers. The receptor layer was reduced to one or two cells thick; receptors had both inner and outer segments, but they were very short and stumpy. The region of immaturity covered about 5 degrees of the retina. These findings suggest that the central region of a human infant's retina is probably not fully functional at birth.

Humans↗

Effect of focus on visual acuity of human infants.

Recent theoretical arguments (Green et al. (1980) Vision Res. 20, 827-835) predict that young human infants should have large depths of focus compared to adults. If so, optical blur should have relatively little effect on the resolving power of infant subjects. We tested this hypothesis by measuring the influence of optical blur on acuity thresholds in 6-week old infants and adults. Using the forced-choice preferential looking (FPL) technique, we obtained acuity thresholds for each subject with five different lens powers (plano, -14 D, -3 D, + 6 D and +14 D). Acuity was differentially affected by lens power in all subjects, with the best acuity produced by high power lenses, both plus and minus, was considerably less for infants than for adults. Although the effects of negative lenses are difficult to interpret without knowing the infants' exact accommodative state, the results with positive lenses support the theoretical predictions.

Accommodation, Ocular↗

Cycloplegic refractions of premature infants.

Cyclopentolate refractions of 146 premature infants disclosed higher incidences of myopia and anisometropia than those reported for full-term infants. Also, more than 70% of the premature infants had I diopter or more of astigmatism; 83% of the astigmatism was against-the-rule. Infants with shorter gestational periods had more severe myopia and astigmatism. Infants born very prematurely should undergo follow-up refractions to determine whether they retain refractive errors large enough to interfere with visual function.

Age Factors↗

Cycloplegic refractions in infants and young children.

We studied groups of normal infants and infants with amblyopia and esoropia to determine the incidence of infantile astigmatism. Under cycloplegia, 19% of normal infants had astigmatism; this was at least twice the incidence in adults, but less than one-hale that found by noncycloplegic refractions of infants. During the first three postnatal years the incidence of astigmatism and distributions of spherical equivalents and anisometropia did not distinguish normal patients from most of those with esotropia and amblyopia.

Adult↗

Behavioral tests of visual acuity in infants.

Two behavioral techniques--OKN and PL--have been used to test visual acuity in young infants in both laboratory and clinical settings. Clinically, OKN is used widely by ophthalmologists as an informal, subjective estimate of an infant's visual status. However, the difficulty of the judgments required and the problem of obtaining good OKN gratings that can be used at a near enough distance to maintain an infant's attention make the procedcure less than ideal. The PL procedure has been used much more widely in laboratory testing than has the OKN procedure, probably because the grating stimuli used are smaller and easier to obtain than OKN stimuli and because the judgments required of the observer necessitate only comparison of the infant's looking behavior in the presence of two stimuli, rather than judgments concerning the presence or absence of a behavior. However, it is only recently that PL procedures, in the form of the diagnostic stripes procedure, have been introduced into clinical settings for measurement of acuity. To date, the diagnostic stripes procedure has proved to be a rapid and practical test to carry out in the clinic, and it appears to be effective in diagnosing infants with ophthalmic problems that would be expected to interfere with vision tested binocularly. However, whether the procedure will be more useful than a standard pediatric or ophthalmic examination for screening infants for visual problems has yet to be determined. In addition, the treatment implications of early detection of poor visual acuity cannot yet be known. To be a truly useful test, a procedure that assesses visual acuity in infants should have prognostic or treatment value--neither of which has been clearly established for the OKN or the PL procedure. The problem is a circular one. We do not know the value of developing tests of visual acuity in infants because the treatment implications and prognostic value of early detection have not yet been established. However, knowledge of the value of early treatment is useless unless early detection is possible. Now that the cycle is beginning to be broken through development of techniques for early detection of poor acuity, research into the prognostic and treatment value of early diagnosis becomes possible for the first time. In conclusion, a number of researchers are working on the development of behavioral techniques for measurement of visual acuity in infants. Whether or not these procedures can be helpful clinically depends on what visual problems can be identified with each technique in the clinic, and whether or not it will turn out to be useful to identify these visual problems at such an early age, a question that can only be answered by further clinical and laboratory observations.

Age Factors↗

Visual acuity screening of preterm infants.

Visual acuity was screened in 36 healthy infants born 4 or more weeks prior to term. Preterm infants tested at 8 and 12 weeks of postnatal age showed significantly poorer performances than those shown by 8- and 12-week-old full-term infants. However, no differences in performance were found when the scores of preterm infants tested at 4, 8, and 12 weeks of postterm age (i.e., 4, 8, and 12 weeks from due date) were compared with scores of 4-, 8-, and 12-week-old full-term infants. The results suggest that visual acuity is more closely correlated with age from conception than with age from birth and that visual acuity screening in preterm infants should be carried out with acuity gratings appropriate for the infant's postterm age rather than with acuity gratings appropriate for the infant's postnatal age.

Age Factors↗

Infant vision testing by a behavioral method.

A behavioral method of screening binocular infant vision called forced choice preferential looking (FPL) has been developed. Clinical trials of the FPL test for young infants are reported here. The test aids nonspecialized personnel in early identification of bilateral ocular abnormalities and anomalies of binocular cooperation (strabismus). It is not possible to screen for monocular eye disease or amblyopia with this test. Modifications of the FPL test may offer new ways of assessing other aspects of visual function early in life.

Age Factors↗

A behavioral method for efficient screening of visual acuity in young infants. I. Preliminary laboratory development.

A technique for rapid behavioral screening of grating acuity in infants 1 to 4 months of age is described. The approach, called forced-choice preferential looking (FPL), depends upon the fact that normal infants will stare fixedly at acuity gratings with stripe widths above a rather abrupt cutoff width. The present task is to find the minimum stripe width, termed the diagnostic stripe width, to which infants with normal visual acuity will readily respond. The expectation is that infants with below-normal acuity will not be able to respond to diagnostic stripes so defined. To assess the feasibility of such a test procedure and define preliminary diagnostic stripe widths for infants 4, 8, 12, and 16 weeks of age, 76 presumptively normal infants were tested in the laboratory with a 40-trial FPL procedure. Sixty-nine infants (91%) completed the test procedure. For each age group, a preliminary estimate of the diagnostic stripe width was found. The group performance was uniformly high for the stripe widths designated as diagnostic and fell off sharply for finer stripes, confirming the feasibility of the approach.

Age Factors↗

A behavioral method for efficient screening of visual acuity in young infants. II. Clinical application.

Visual performance in 130 infants was assessed in a clinical setting with the forced-choice preferential looking (FPL) method described by Dobson et al.5 Over 90% of infants completed testing. Testing usually required less than 10 min. One group of infants tested also underwent complete ophthalmic examination. The second, larger group was screened with handlight examinations and FPL testing; any abnormalities detected were evaluated by full ophthalmic examination. Results so far indicate that the FPL test accurately identifies babies with binocular visual problems and that, when coupled with a handlight examination, it provides efficient screening for ocular problems in infants 0 through 16 weeks of age (postterm).

Age Factors↗

Pattern reversal visually evoked potentials in infants.

Visually evoked potentials (VEP) were recorded from infants two to six months of age using a checkerboard pattern reversal stimulus. By six months, infants produced the largest amplitude VEP to checks subtending visual angles of 7.5 or 15 minutes of arc, as do adults with 20/20 acuity. This finding indicates that by six months an infant's sensory capacity for a visual acuity of 20/20 is established.

Adult↗

Long-term effect of phototherapy on visual function.

Computer-averaged electroretinogram records were used to examine scotopic retinal functioning of a group of 4-year-old children who were treated for neonatal hyperbilirubinemia by exposure to at least 42 consecutive hours of continuous phototherapy. Dark adaptation functions of the children were similar to those previously found for control subjects, suggesting that no permanent damage to rod function had been incurred during exposure. Statistical analysis showed no significant differences in the final electroretinographic amplitudes of light-treated and control subjects. Ophthalmologic and neurologic examinations were also negative.

Birth Weight↗