PubMed Health⌕ Search

Biomedical subjects

V E Green

Publications and source records attributed to V E Green.

4 recordsLinked to original sources

An improved analysis for chlorinated pesticides and polychlorinated biphenyls (PCBs) in human and bovine sera using solid-phase extraction.

Chlorinated pesticides and polychlorinated biphenyls (PCBs) remain public health concerns because of their unresolved health impact and their persistence in humans. Current epidemiological studies of cancer, non-Hodgkins lymphoma, and endocrine disruption in National Center for Environmental Health (NCEH) laboratories require exposure assessment of many analytes in thousands of people. Previous methods of analyzing pesticides and PCBs in serum have proven inadequate for timely processing of the number of samples required for epidemiological studies. A new method that involves solid-phase extraction (SPE) and cleanup followed by dual-column gas chromatographic separation and electron capture detection has been developed. Nine surrogate compounds were added to the serum prior to sample workup to provide quality assurance for the SPE steps. These surrogates mimic the chemistry of the analytes in the extraction, cleanup, and gas chromatographic analysis steps. To increase selectivity, extracts were injected onto two gas chromatographs with different capillary columns, a DB-1701 and a DB-5. Recoveries of 17 pesticides, 28 PCB congeners, and one polybrominated biphenyl congener ranged from 40 to 80%. Recoveries from this procedure were found to be similar to those from the previously used liquid-liquid extraction method. Correlation of analyte and surrogate recoveries were compared to examine the ruggedness of the technique. The SPE method was found to provide improved sample throughput by a factor of 15.

Animals↗

Determination of Mirex in human blood serum containing polychlorinated biphenyls by using packed column gas chromatography.

An analytical method has been developed that uses electron capture/gas-liquid chromatography to determine Mirex in serum containing polychlorinated biphenyls (PCBs) (Aroclor 1260). With this method, 0.2 ppb Mirex can be determined in 4 mL serum that also contains 10 ppb PCBs. The method provides approximately 70% recovery of Mirex at 1.0 and 3.5 ppb. The coefficients of variation are 4.5 and 4.6% at 1.0 and 3.5 ppb, respectively. In a cooperative study with the Ohio Department of Health, the Centers for Disease Control used this method to determine the extent of exposure of Salem, OH, residents to Mirex. Confirmation of Mirex was obtained by using high resolution gas chromatography and high resolution mass spectrometry.

Chromatography, Gas↗