PubMed HealthSearch

Biomedical subjects

V E Paul

Publications and source records attributed to V E Paul.

14 recordsLinked to original sources

A prospective study of the efficacy and safety of adjuvant metoprolol and xamoterol in combination with amiodarone for resistant ventricular tachycardia associated with impaired left ventricular function.

Combination antiarrhythmic drug therapy may be more effective than treatment with a single agent for control of refractory cases of sustained ventricular tachycardia (VT). In a prospective randomized crossover study of 20 patients with impaired left ventricular function (ejection fraction of 28% +/- 8%) and recurrent VT in spite of treatment with amiodarone, we compared the efficacy and safety of adjuvant therapy with metoprolol, 50 mg two times daily and xamoterol, 200 mg two times daily. Metoprolol caused hemodynamic deterioration in five patients, and only one also experienced intolerance to xamoterol. Sustained VT was inducible in all 20 patients who were receiving amiodarone alone but was suppressed or rendered nonsustained in 8 of 20 patients during treatment with amiodarone plus xamoterol and in 6 of 17 patients during treatment with amiodarone plus metoprolol. Addition of xamoterol restored sinus rhythm in four patients who presented with incessant VT, and metoprolol was effective for three of them. Neither beta-blocker significantly altered tachycardia cycle length or any electrophysiologic parameter other than the slowing of the sinus rate. Both beta-blockers suppressed exercise-induced VT in 3 of 4 patients, and addition of xamoterol significantly increased treadmill exercise duration (7.1 +/- 1.8 min) compared with administration of amiodarone alone (3.8 +/- 1.5 min; p < 0.01). Fourteen patients were discharged with prescriptions for amiodarone-beta-blocker combinations. During a mean follow-up period of 13 months (range, 2 to 24 months), there were three cases of recurrent VT (in all patients VT remained inducible) and no sudden deaths.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult

Differentiation between monomorphic ventricular tachycardia and sinus tachycardia based on the right ventricular evoked potential.

The differentiation between ventricular tachycardia (VT) and sinus tachycardia (ST) is problematic in some patients with implantable defibrillators and/or antitachycardia pacemakers. The integral of the ventricular endocardial evoked response, or paced depolarization integral (PDI), has been demonstrated to undergo characteristic changes with a variety of stimuli including catecholamines, pacing rate, and exercise. We hypothesized that the PDI recorded from a unipolar transvenous right ventricular endocardial catheter would differentiate VT from ST. The PDI was calculated from a unipolar pacing stimulus, delivered via a cathode in the right ventricular apex, and the reference electrode, a quadripolar catheter positioned in the superior vena cava. PDIs were measured in 22 patients during VT and sinus rhythm. The PDI measured during sinus rhythm was 579 +/- 240 microV-sec and the PDI during VT was 894 +/- 411 microV-sec (P < 0.001). In a subset of seven patients, PDIs were measured during VT, sinus rhythm, and ST induced by catecholamine infusion or exercise. In this subset, the PDI during sinus rhythm was 645 +/- 295 microV-sec, during ST 588 +/- 308 microV-sec (9% decrease from sinus, P = 0.05), and during VT 863 +/- 342 microV-sec (33.9% increase, P = 0.01). These data indicate that the measurement of the PDI is potentially useful in differentiating VT from ST.

Algorithms

Transtelephonic interrogation of the implantable cardioverter defibrillator.

Third generation implantable cardioverter defibrillators (ICDs) have extensive memory capability to store data about the patient's arrhythmias and the effect of therapies delivered by the ICD. However, this data has so far been accessible only when the patient attends the pacing clinic. Two Medtronic 9421 PCD TeletraceR transmitters have been used to interrogate Medtronic 7216A and 7217B PCD S at distances of up to 300 miles from our hospital and transmit the data to a 9420 PCD TeletraceR receiver. Successful transmission of data has been obtained on 50 occasions with 100% data concordance with repeat transmission. The system can reduce the number of unscheduled clinic visits, reduce delay in making a diagnosis following unexpected delivery of a shock therapy, and reassure patients about to be discharged following ICD implantation. The benefits are magnified where patients reside far away from the implanting center.

Electric Countershock

Comparative electrophysiological effects of captopril or hydralazine combined with nitrate in patients with left ventricular dysfunction and inducible ventricular tachycardia.

OBJECTIVE: To assess the electrophysiological and antiarrhythmic effects of pharmacological load manipulation by an angiotensin converting enzyme (ACE) inhibitor (captopril) and a direct vasodilator (hydralazine plus isosorbide mononitrate) in patients with inducible ventricular tachycardia and impaired left ventricular function. DESIGN: Randomised open label cross-over comparison of three regimens. SETTING: Tertiary arrhythmia referral centre. SUBJECTS: Eight patients with reduced left ventricular function and sustained ventricular tachycardia inducible by programmed stimulation. INTERVENTIONS: Three treatment regimens each of 48 hours duration: captopril, hydralazine plus isosorbide mononitrate, and control (no vasodilator). MAIN OUTCOME MEASURES: Changes in central haemodynamics, electrophysiological parameters, and induction of ventricular tachycardia during treatment with captopril, or hydralazine combined with nitrate, compared with a control period. RESULTS: Both vasodilator treatments produced similar balanced reductions in peak systolic pressures and filling pressures compared with controls. Captopril had no effect on sinus cycle length, atrial refractoriness, or intraventricular conduction, but prolonged ventricular effective and functional refractory periods and QT interval during constant rate atrial pacing. Hydralazine combined with nitrate did not significantly alter any electrophysiological variable. Ventricular tachycardia was similarly inducible during all three periods. CONCLUSIONS: Load manipulation by captopril but not hydralazine combined with nitrate prolonged ventricular refractoriness and repolarisation, possibly reflecting a combination of mechano-electrical effect with the restraining influence of ACE inhibitors on reflex sympathetic stimulation.

Aged

The electrophysiological effects of flosequinan.

We have evaluated the acute electrophysiological effects of flosequinan in 18 patients with normal ventricular function. Following intravenous infusion of flosequinan 100 mg over 1 h, mean (SD) systolic blood pressure fell from 131 +/- 19 to 120 +/- 22 mmHg (P less than 0.02) and there was significant shortening of sinus cycle length (732 +/- 151 to 575 +/- 93 ms, P less than 0.001), AH interval (110 +/- 45 to 71 +/- 19 ms, P less than 0.01), QRS duration (98 +/- 28 to 91 +/- 26 ms, P less than 0.02) and QT interval (373 +/- 47 to 337 +/- 35 ms, P less than 0.001), but no change in sinus node recovery time, intra-atrial conduction time, HV interval or the corrected QTc interval. There was a reduction in both anterograde atrioventricular Wenckebach cycle length (299 +/- 53 to 259 +/- 52 ms, P less than 0.01) and retrograde ventriculoatrial Wenckebach cycle length (375 +/- 77 to 300 +/- 56 ms, P less than 0.01). There was no change in atrial or ventricular effective refractory period (ERP) but atrial functional refractory period (FRP) shortened (233 +/- 31 to 212 +/- 24 ms, P = 0.07) as did ventricular FRP (249 +/- 24 to 234 +/- 21 ms, P less than 0.01). Patients received an oral dose of flosequinan 50 mg 12 h later. By 24 h, sinus cycle length, QRS duration and the QT interval had all returned towards baseline values, but ventricular ERP had lengthened (199 +/- 22 to 215 +/- 26 ms, P less than 0.06).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult

Automatic recognition of ventricular arrhythmias using temporal electrogram analysis.

Future antitachycardia devices must be able to deliver a variety of therapies according to the requirements of the underlying arrhythmia. To ensure that appropriate treatment is prescribed the device must use a detection algorithm that is able to discriminate between multiple arrhythmias. Current criteria such as rate, change of rate, duration at high rate, and high rate stability are inadequate for this purpose. Many algorithms that evaluate the morphology of the endocardial electrogram are of too great a complexity to be incorporated in implantable devices that require real-time analysis without undue power consumption. In this study the sensitivity of a simple morphological technique (temporal electrogram analysis) is examined. The method sets threshold 'rails' above and below the isoelectric line and classifies ECG complexes according to the sequence and duration of rail excursions. A total of 27 ventricular tachyarrhythmias were induced in 25 patients (17 with a history of recurrent arrhythmias and eight undergoing risk stratification postmyocardial infarction). Temporal electrogram analysis (TEA), initially detected the onset of the ventricular arrhythmia in all patients whose surface ECG showed polymorphic or right bundle branch block pattern tachycardia, in 5/8 of cases with left bundle branch block pattern and in 4/5 of patients with concordant complexes across the precordial leads. After minor modifications the overall sensitivity of the method was improved to 95% (26/27 arrhythmias detected). TEA is a technique of low computational demands, which in this study, reliably discriminated between resting sinus rhythm and ventricular arrhythmias.

Adult

Influence of propranolol on the ventricular depolarization gradient.

Sensing of the ventricular depolarization gradient (VDG) has recently been used as the basis of a closed-loop rate responsive pacemaker. Factors influencing this aspect of the evoked response have not been fully evaluated although previous reports have suggested that sympathetic stimulation and circulating catecholamines are primarily responsible for the observed changes during stress and exercise. In five patients (Table I), four males and one female (mean age 60.4 +/- 10.1 years) implanted with the Prism pacemaker, the pacing response to exercise and tilting was assessed before and after the infusion of propranolol. There was an increase in the pacing rate in all patients during the infusion of the drug (mean 27 +/- 12.9 beats/min) suggestive of a direct drug effect on the VDG. The rate control parameter (RCP) of the pacemaker, the numerical equivalent of the VDG, was significantly different after the administration of propranolol (P less than 0.01). However, exercise performance and pacing rate behavior were not different after beta blockade. The pacing rate increase observed when tilting patients to the supine position was not altered by propranolol. Out date suggest that factors other than adrenergic stimulation may be of importance in affecting the ventricular evoked response and accordingly the rate adaptation of the Prism pacemaker.

Adrenergic beta-Antagonists

Open access exercise electrocardiography: a service to improve management of ischaemic heart disease by general practitioners.

An initial study of the use of open access exercise electrocardiography by general practitioners (GPs) in South East Kent showed that patient selection and interpretation of test results was frequently incorrect. After issuing guidelines, modifying the request form and instituting registrar review of all requests, significant improvements in both referral pattern, result interpretation and patient management have resulted. Forty-nine GPs requested 110 exercise tests during 1988/89. Twelve per cent were not undertaken after discussion with the referring practitioner. Eighty-four per cent of those tested would have been referred to the district general hospital cardiology outpatient department in the absence of open access exercise electrocardiography service. Six per cent of patients were referred directly for invasive investigation. Thirty-five per cent were referred to the district general hospital cardiology outpatient department, whilst 42% were spared hospital referral based on the result of the investigation. Better use of the modified service was suggested by: referral of fewer patients with non-cardiac chest pains (P = 0.002); more patients with a moderate pre-test probability of ischaemic heart disease (P less than 0.05); fewer inappropriate requests (P less than 0.01); and fewer inappropriately undertaken tests (P less than 0.001) than in the previous study. All patients with strongly positive test results were appropriately managed. Open access exercise electrocardiography in the format investigated is potentially a cost-effective and useful tool to improve diagnosis and management of heart disease by GPs.

Adolescent

Myocardial infarction and biventricular free-wall rupture with shunting through a false aneurysm.

A 65-year-old man presented with acute inferior myocardial infarction and received thrombolytic therapy with clinical evidence of coronary arterial recanalisation. Recovery was uncomplicated until- the eighth day when he experienced recurrent chest pain with evidence of reinfarction in the same territory. This was associated with the development of a pansystolic murmur and cardiogenic shock. Cardiac catheterisation showed right coronary arterial occlusion and inferior infarction with a false aneurysm and a left-to-right shunt (shunt ratio 2.5:1). Surgery confirmed the formation of a false aneurysm caused by rupture of the free walls of both ventricles. Importantly, however, the interventricular septum was intact and the left-to-right shunt was through the false aneurysm itself. This is the first report of biventricular free-wall rupture with shunting through a false aneurysm treated successfully by surgery.

Aged

Variability of the intracardiac electrogram: effect on specificity of tachycardia detection.

Correlation has been described as a method of high sensitivity to distinguish ventricular arrhythmias from sinus rhythm but the specificity of this algorithm has not been assessed. Ten patients with a history of chronic ventricular tachycardia were studied. The ventricular endocardial electrogram was recorded during sinus rhythm at rest immediately following exercise and during their clinical ventricular tachycardia. Each complex recorded during these sample periods was correlated with a template constructed during sinus rhythm at rest. Although for each patient the range of correlation values obtained at rest were clearly separated from those obtained during ventricular tachycardia, in 69% of cases there was overlap of the range in sinus tachycardia and ventricular tachycardia.

Adult

Temporal electrogram analysis: algorithm development.

The automatic discrimination of physiological from pathological tachycardias by rate criteria alone lacks adequate specificity. Tachycardia detection algorithms based upon morphological analysis of the endocardial electrogram have been attributed high specificity although their specificity has not been proven. A previous study had shown temporal electrogram analysis (TEA) to be an algorithm of high sensitivity in the detection of ventricular arrhythmias despite low computational demands. In this study, the specificity and potential for automatic implementation have been assessed. Manual adjustment of thresholds for individual patients gave a maximum potential sensitivity of 97% (26/27 arrhythmias correctly recognized as non-sinus). The use of automatic setting of thresholds reduced sensitivity to 81%. The specificity of the algorithm, as assessed by exercise testing, was only 60%.

Adult

Open access exercise electrocardiography: does it improve the management of cardiovascular disease in the community?

In this study the use of exercise electrocardiography, by 47 general practitioners in South East Kent has been evaluated. Of 110 consecutive requests the majority (88%) were for diagnostic purposes, while only 7% were for prognostic assessment. Many of those referred were young or had non-cardiac chest pain and in 59% of cases the test result was unlikely to alter the clinical assessment of the probability of ischaemic heart disease (IHD). The test result influenced patient management in 85% of cases. Only 15% of patients were subsequently referred to the district general hospital although all had been considered for referral prior to the test. Although referral for invasive investigation of six patients was expedited by the provision of stress testing, in five patients general practitioners failed to consider any further investigation despite the patient having a strongly positive test. General practitioners use exercise electrocardiography primarily to exclude IHD in patients at low risk and provide reassurance. They rarely use the test as a means to guide management of those with known or probable IHD.

Cardiovascular Diseases

Cardiac involvement by lymphoma: diagnostic difficulties.

A patient presenting with recurrent tamponade was subsequently shown to have non-Hodgkin's lymphoma. Catheterization demonstrated obstruction of the tricuspid valve by tumour and shunting through a patent foramen ovale. The difficulties in making an ante-mortem diagnosis of cardiac lymphoma are discussed.

Aged