Optical properties of normal and diseased human breast tissues in the visible and near infrared.

The optical absorption and scattering coefficients have been determined for specimens of normal and diseased human breast tissues over the range of wavelengths from 500 to 1100 nm. Total attenuation coefficients were measured for thin slices of tissue cut on a microtome. The diffuse reflectance and transmittance were measured for 1.0 mm thick samples of these tissues, using standard integrating sphere techniques. Monte Carlo simulations were performed to derive the scattering and absorption coefficients, as well as the mean cosine of the scattering angle. The results indicate that scatter exceeds absorption by at least two orders of magnitude. Absorption is most significant at wavelengths below 600 nm. The scattering coefficients lie in the range 30-90 mm-1 at 500 nm, and fall smoothly with increasing wavelength to between 10 and 50 mm-1 at 1100 nm. The scattering coefficient for adipose tissue differs, in that it is invariant with wavelength over this spectral range. For all tissues examined, the scattered light is highly forward peaked, with the mean cosine of the scattering angle in the range 0.945-0.985. Systematic differences between the optical properties of some tissue types are demonstrated.

Breast

Modification of a standard cobalt-60 unit for total body irradiation at 150 cm SSD.

A cobalt-60 teletherapy unit has been modified to permit total body irradiation (TBI) with a vertical beam in a conventional treatment room. This technique has been implemented at low cost using a few easily made accessories. Removal of the adjustable collimator assembly provides a field 2.3 meters in diameter at 150 cm SSD. A copper flattening filter has been constructed to improve beam uniformity and remove electron contamination. Machine set up time for TBI requires less than 15 minutes and does not affect the routine clinical use of the unit. A dose rate of 32 cGy per minute (midplane) is attainable in a 20 cm thick patient. The dosimetry and technical aspects are presented in this paper.

Cobalt Radioisotopes

Laser backpointer for use with a radiotherapy simulator.

A radiotherapy simulator with image intensification has been equipped with a laser backpointer which does not need to be removed during fluoroscopic examinations, provides negligible interference with the fluoroscopic image, and results in significant reductions in the time required for mark-up of patients. Accuracy of set-ups may be improved since rechecking of patient positioning has been simplified.

Lasers