PubMed Health⌕ Search

Biomedical subjects

V G Skvortsov

Publications and source records attributed to V G Skvortsov.

At least 19 recordsLinked to original sources

Structure and activity of NO synthase inhibitors specific to the L-arginine binding site.

Synthesis of compounds containing a fragment similar to the guanidine group of L-arginine, which is a substrate of nitric oxide synthase (NOS), is the main direction in creating NOS inhibitors. The inhibitory effect of such compounds is caused not only by their competition with the substrate for the L-arginine-binding site and/or oxidizing center of the enzyme (heme) but also by interaction with peptide motifs of the enzyme that influence its dimerization, affinity for cofactors, and interaction with associated proteins. Structures, activities, and relative in vitro and in vivo specificities of various NOS inhibitors (amino acid and non-amino acid) with linear or cyclic structure and containing guanidine, amidine, or isothiuronium group are considered. These properties are mainly analyzed by comparison with effects of the inhibitors on the inducible NOS.

Animals↗

Effect of NO synthase inhibitor 2-amino-5,6-dihydro-4H-1,3-thiazine on endotoxin-induced changes in hemodynamic parameters and respiration in rats.

We studied the effect of NO synthase inhibitor 2-amino-5,6-dihydro-4H-1,3-thiazine (2-ADT) on the cardiovascular system in rats with endotoxic shock. Blood pressure, heart rate, and respiratory rate were recorded. E. coli lipopolysaccharide decreased blood pressure and heart rate. 2-ADT in a dose of 5 mg/kg normalized these hemodynamic parameters. The normalizing effect of 2-ADT decreased with increasing the dose of this preparation. 2-ADT in high doses (10, 20, and 30 mg/kg) and repeated injections of the preparation caused death of experimental animals.

Animals↗

Calibration of EPR signal dose response of tooth enamel to photons: experiment and Monte Carlo simulation.

The experimental energy dependence of the electron paramagnetic resonance (EPR) radiation-induced signal at irradiation by photons in the energy range of 13 keV-1.25 MeV was analysed in terms of the absorbed dose in human tooth enamel. The latter was calculated using a Monte Carlo simulation of the photon and electron transport. The dependence of the calculated absorbed dose on the sample thickness was analysed. No energy dependence of the EPR signal on the absorbed dose in enamel was verified in the range of 37 keV-1.25 MeV. At 13 and 20 keV the EPR signal dose response was reduced by 8% probably due to sample powdering. Dose-depth profiles in enamel samples irradiated by 1.25 MeV photons in polymethylmethacrylate and aluminium build-up materials were calculated. It was concluded that secondary electron equilibrium conditions are better fulfilled for irradiation in aluminium, which makes this material preferable for calibration.

Algorithms↗

Dose reconstruction by EPR spectroscopy of tooth enamel: application to the population of Zaborie village exposed to high radioactive contamination after the Chernobyl accident.

Individual irradiation doses were determined by electron paramagnetic resonance spectroscopy of the tooth enamel of the inhabitants of Zaborie, the most contaminated inhabited settlement not evacuated after the Chernobyl accident. Dose determination was performed using a specially developed automatic spectrum processing procedure. Spectrum processing was carried out in different operating modes, and average results were taken in order to reduce the contribution of uncertainty in dose determination caused by spectrum processing. The absorbed doses determined in enamel were corrected to take into account the contribution of natural background radiation and to determine the individual excess dose due to radioactive contamination of the territory. Individual excess doses are compared to calculated individualized doses to teeth, estimated using the local radioactive contamination levels, dose rates, and information concerning individual behavior. The individual excess doses measured by electron paramagnetic resonance spectroscopy and the calculated individualized doses are fully independent. Mean square variation between results of two methods was found to be 34 mGy, which is consistent with error estimation for both methods. This result can validate both the methodology of signal processing presented here when using electron paramagnetic resonance dosimetry of tooth enamel for low doses and the methodology of individualized dose calculation.

Algorithms↗

NO-inhibiting and vasotropic activity of some compounds with thioamidine group.

Using the method of electron paramagnetic spectroscopy we demonstrated that thiazine-thiazoline compounds and aminoethyl isothiourea containing the thioamidine group inhibit NO production in the liver of endotoxin-treated mice. Injection of these agents to anesthetized rats increased arterial pressure and enhanced respiration rate. This effect probably reflects inhibition of not only inducible, but also the constitutive synthesis of NO by compounds with thioamidine group.

Animals↗

Optimisation of recording conditions for the electron paramagnetic resonance signal used in dental enamel dosimetry.

Optimisation of the parameters for recording the electron paramagnetic resonance (EPR) spectra of dental enamel for absorbed dose reconstruction was performed for an EMX (Bruker) spectrometer supplied with a high-sensitivity microwave cavity. Dose determination was performed using a previously developed automatic spectra processing procedure, which uses the non-linear fit of a model spectrum. The experimental error was estimated as the standard deviation of the results from the nominal doses for the set of spectra recorded for 10 samples prepared from teeth of different persons and irradiated in the dose range 0-500 mGy. The microwave power and magnetic field modulation amplitude corresponding to the minimum of dependencies of the error on these parameters were adopted as the optimal ones. For the sets of spectra recorded at optimal parameters for sample masses 100, 50 and 30 mg, the errors of dose determination were obtained as 18, 27 and 37 mGy respectively.

Adult↗

Individual dose reconstruction among residents living in the vicinity of the Semipalatinsk nuclear test site using EPR spectroscopy of tooth enamel.

Individual accumulated doses were determined by EPR spectroscopy of tooth enamel for 26 adult persons residing in territories adjacent to the Semipalatinsk Nuclear Test Site (SNTS). The absorbed dose values due to radiation from nuclear tests were obtained after subtracting the contribution of natural background radiation from the total accumulated dose. The determined dose values ranged up to 250 mGy, except for one person from Semipalatinsk city with a measured dose of 2.8 +/- 0.4 Gy. Increased dose values were determined for the individuals whose teeth were formed before 1962, the end of the atmospheric nuclear tests. These values were found to be significantly larger than those obtained for a group of younger residents of heavily exposed territories and the residents of territories not exposed to radioactive fallout. These increased dose values are consistent with those based on officially registered data for the Northeastern part of Kazakstan adjacent to SNTS, which was exposed to high levels of radioactive fallout from nuclear tests in period 1949-1962.

Adult↗

Elimination of the background signal in tooth enamel samples for EPR-dosimetry by means of physical-chemical treatment.

A method of elimination of the background EPR signal in tooth enamel is proposed. This method implies treatment of enamel powder by highly active reduction reagent hydrazine with subsequent washing out by ethanol-water solution. Such treatment results in reducing both the native background signal (which is assumed to be originated by the organic component) and the mechanical induced EPR signal in enamel. Testing of the efficiency of hydrazine treatment is made for different sizes of enamel powder. It is shown that the optimal results are obtained for a powder fraction of about 100-200 microm. The radiation-induced EPR signal in enamel is practically not changed after treatment by hydrazine.

Chemical Phenomena↗

Possibility of using porcelain samples of high-voltage line insulators for radiation dose reconstruction by EPR spectroscopy.

In electron paramagnetic resonance spectra of irradiated porcelain samples from high-voltage supply line insulators three overlapping single signals were observed. The dependencies of the amplitude of these signals on the microwave power, irradiation dose and the stability in darkness and in natural light were investigated. It was concluded that for dosimetric purposes it is reasonable to use the radiation-induced signal with g = 2.001, which could be ascribed to the E' centres of quartz. The microwave power dependence of the amplitude of this signal is saturated at 1 mW, the dose dependence is saturated at about 60 mGy. A minimal level of dose determination is about 1 Gy, and it is limited mainly by the accuracy of subtraction of the background signal existing in the unirradiated sample. The radiation-induced signal is stable in the darkness, but rapidly faded in natural light, therefore, for dosimetric purposes it is possible to use only insulators covered with dark glaze or ceramic samples from the very interior of the insulators.

Ceramics↗

EPR tooth enamel dosimetry: optimization of the automated spectra deconvolution routine.

A computer routine was developed for automatic deconvolution of electron paramagnetic resonance spectra of tooth enamel samples for individual radiation dose reconstruction in the low dose region. The deconvolution routine uses the non-linear least square fit of a model simulating a tooth enamel spectrum by superposition of derivative Gaussian functions to obtain the amplitude of the dosimetric radiation induced signal. The parameters of the model and of the routine were optimized on a dose response level using a criterion of the least standard deviation of the derived radiation induced signal amplitude from the regression line vs. the nominal doses for the series of spectra of samples irradiated in known doses in the range 0-500 mGy. It was found that for the series of spectra of the heterogeneous samples (every sample is prepared from different teeth of different persons), it is essential to vary in the least square fit the parameters describing the shape of the native background signal in order to obtain the best accuracy. In the case of the series of spectra of the homogeneous (pooled) samples, almost the same accuracy of the results was obtained using the procedures with varied and fixed background signal parameters. The standard error of the dose reconstruction by the optimized deconvolution procedure was estimated as about 30 mGy for heterogeneous samples and 20 mGy for homogeneous samples.

Algorithms↗

[Functional suitability of iodinated casein in the prevention of iodine deficiency].

At least 1.5 billion in the world and over 100 million Russians live in iodine-deficiency areas. The sequelae of this condition are well known. The paper discusses the properties of the iodinated lactoprotein caseoiodine designed by the MRRC researchers and its capacities and advantages for using in the prevention of iodine deficiency. The assimilation of iodine from caseoiodine corresponds to the body's status: it significantly accumulates more frequently in the thyroid in dietary iodine deficiency (Group 1) and to a lesser degree in adequate dietary iodine intake (Group 2) and, by hour 72, amounts to 36.3 and 31.4% of the ingested amount, respectively (P < 0.05). The findings are in agreement with the data available in the literature on the involvement of hepatic enzymes in regulating the metabolism of iodine during its intake in the protein (casein)-bound form and in increasing its fecal excretion (up to 40% in Group 2) whereas 95% iodine excrete with urine when inorganic iodine is consumed.

Animals↗

Application of EPR retrospective dosimetry for large-scale accidental situation.

Above 3000 tooth enamel samples, collected at population of radioactive contaminated territories after Chernobyl accident, the Chernobyl liquidators, the retired military of high radiation risk and the population of control radiation free territories were investigated by EPR spectroscopy method in order to obtain accumulated individual exposure doses. Results of EPR spectra measurements are stored in data bank; enamel samples are also stored in order to provide the possibility to repeat the measurements in future. Statistical analysis of results has allowed to detect the contribution into EPR signal in tooth enamel due to the action of the natural background radiation, and the radioactive contamination of territory. In general, the average doses of external exposure of the population obtained with EPR spectroscopy of teeth enamel are consistent with results based on other methods of direct and retrospective dosimetry. Essential exceeding of the individual doses above the average level within the population groups was observed for some persons. That gave the possibility to detect the individuals with overexposure, which were included into groups for medical monitoring.

Case-Control Studies↗

Tooth enamel EPR dosimetry: sources of errors and their correction.

Some of the most important sources of systematic errors in dose determination using tooth enamel EPR spectroscopy and ways of reducing those errors are discussed. Enamel from the outside of the front teeth should not be used for dose determination because of induction of paramagnetic centers by solar light. The accuracy of the method in the low dose range is limited by variation in the shape of the EPR signal of unirradiated enamel, which can be described by an initial intrinsic signal and which varies for different samples with standard deviation of 20-30 mGy. The energy dependence of enamel sensitivity should be taken into account in the form of a correction factor. The value of this factor is estimated at 1.1-1.3 for real radiation fields in radiation contaminated territories. Variation in enamel sensitivity for different samples is shown to be within limits of 10-15% of the average value.

Dental Enamel↗

[Combined action of UV light and alpha particles on yeast cells of different genotypes].

Combined action of ultraviolet (UV) light and alpha-particles on yeast cells of different genotypes has been studied. Under combined action, after small doses of UV-light the oscillated changes of cell survival were registered for wild-type cells independent of the ploidy and the sequence of application of radiations. Additive effect of high doses of UV-light and ionizing radiation was expressed for strains incapable of the recovery of damages induced by ionizing radiation. For yeast cells possessing such a capability, the synergistic interaction of damages inflicted by high doses of UV-light and alpha-particles was noted. Possible reasons of the observed cell responses are discussed.

Alpha Particles↗