Plasma-particle interactions in a laser-induced plasma: implications for laser-induced breakdown spectroscopy.

The interaction between laser-induced plasmas and individual particles controls the rate of particle dissociation and subsequent atomic diffusion and emission processes, with implications for single-particle spectroscopy, as well as materials synthesis and other plasma sources. It is demonstrated through quantitative plasma imaging studies that discrete particles dissociate on a time scale of tens of microseconds within plasmas formed by 300-mJ Nd:YAG laser pulses. Significant spatial nonhomogeneity, as measured by localized atomic emission from particle-derived calcium atoms, persists on a comparable time scale, providing a measure of their average atomic diffusion rate of 0.04 m(2)/s. In addition, the resulting calcium atomic emission is explored using image analysis as well as traditional spectroscopic analysis.

Journal Article↗

Laser-induced breakdown spectroscopy for ambient air particulate monitoring: correlation of total and speciated aerosol particle counts.

A statistical analysis of ambient air particle monitoring, namely PM2.5, is presented to elucidate the correlations between laser-induced breakdown spectroscopy (LIBS)-based speciated aerosol monitoring and non-speciated aerosol monitoring (i.e., total particle counts). LIBS was used in a real-time, conditional-processing mode to identify individual aerosol particles containing detectable quantities of either calcium or sodium, as based on the resulting atomic emission signals. Using this technique, real-time measurements of speciated aerosol particle concentrations and analyte mass concentrations were evaluated for a total of 60 1-hour sampling periods spread over a 5-week period. For each 1-hour sampling period, total aerosol counts were simultaneously monitored using a commercial light scattering-based instrument. Over the 30 sampling periods, aerosol counts (both total and LIBS-based) were found to vary by more than one order of magnitude. For aerosol particles in the 500 nm to 2.5 microm size range, significant correlations were found between the two sampling methods, resulting in correlation coefficients (r2) ranging from 0.22 to 0.93. In addition, transient fluctuations in aerosol counts on a timescale of 5 to 10 minutes were successfully observed simultaneously with the two monitoring techniques, thereby demonstrating the temporal resolution of LIBS.

Aerosols↗

Calibration effects for laser-induced breakdown spectroscopy of gaseous sample streams: analyte response of gas-phase species versus solid-phase species.

The effects of analyte phase on the calibration response for laser-induced breakdown spectroscopy is investigated for a range of carbon species. Significant differences in the atomic emission signal from carbon were observed when comparing calibration streams of gas-phase and submicrometer-sized solid-phase carbon species. The resulting calibration curve slopes varied by a factor of 8 over a comparable range of atomic carbon concentrations for five different analyte sources, while the plasma electron density and temperature remained essentially constant. The current findings challenge a widely held assumption that complete dissociation of constituent species within a highly energetic laser-induced plasma results in independence of the analyte atomic emission signal on the analyte source. A physical model of the plasma-analyte interaction is proposed that provides a framework to account for the observed dependence on the physical state of the analyte.

Journal Article↗

Hydrogen leak detection using laser-induced breakdown spectroscopy.

Laser-induced breakdown spectroscopy (LIBS) is investigated as a technique for real-time monitoring of hydrogen gas. Two methodologies were examined: The use of a 100 mJ laser pulse to create a laser-induced breakdown directly in a sample gas stream, and the use of a 55 mJ laser pulse to create a laser-induced plasma on a solid substrate surface, with the expanding plasma sampling the gas stream. Various metals were analyzed as candidate substrate surfaces, including aluminum, copper, molybdenum, stainless steel, titanium, and tungsten. Stainless steel was selected, and a detailed analysis of hydrogen detection in binary mixtures of nitrogen and hydrogen at atmospheric pressure was performed. Both the gaseous plasma and the plasma initiated on the stainless steel surface generated comparable hydrogen emission signals, using the 656.28 Halpha emission line, and exhibited excellent signal linearity. The limit of detection is about 20 ppm (mass) as determined for both methodologies, with the solid-initiated plasma yielding a slightly better value. Overall, LIBS is concluded to be a viable candidate for hydrogen sensing, offering a combination of high sensitivity with a technique that is well suited to implementation in field environments.

Equipment Design↗