[Endometrial ablation by liquid heat using the EnAbl system in patients after abdominal hysterectomy. Study of safety].

Security and efficacy of an EnABL, were evaluated; this system had been designed for endometrial ablation by liquid heat in uterine cavity. Eleven patients were included, from the Outpatient Department (INP), programmed for different causes that objectives of this study for abdominal hysterectomy due to abnormal uterine bleeding. The study was approved by Ethical and Scientific Committees. Each patient had preoperative studies, endometrial biopsy, PAP, and ultrasound, in series. The patients with uterus larger than 14 cm, possible cancer; younger than 18 year, or with active bleeding at the time of hysterectomy, were excluded. Each patient received a schema of standard endometrial suppression. The system was applied previously to TAH; 2271 measurements of temperature at one minute intervals were done during liquid heat application. Surgical pieces were sent to histology to analyze the thermic damage through macroscopic aspect, HE tinction and an immunohistochemical cellular viability of NADH test. The thermal damage by macroscopic appearance was 4.33 +/- 1.03 mm, with HE of 4.15 +/- 0.75 mm and with the tinction of NADH of 4.25 mm +/- 0.79. The maximal damage by macroscopic appearance was 4.33 +/- 1.03 mm, with HE of 4.15 +/- 0.75 mm, and with NADH it was 4.25 mm +/- 0.79. The maximal damage was by macroscopic appearance was 6.0 mm and the minimal one was 2.0 mm. In evaluation by H/E, maximal was 5.1 mm and the minimal one was 2.3 mm. In NADH tinction maximal was 4.25 and minimal 2.4 mm. Horizontal analysis showed eight patients with major thermal damage at 4 mm; and two patients with lesser damage at 4 mm. Sub-serous temperatures measured with thermopairs, were done 1504 times, in total. Average was 36.28 degrees C, ranging 35 to 37 degrees C. Maximal temperature was 45 degrees C, 1-2 mm, bellow from serous surface of uterus, and the last one was 28 degrees C. The serous temperatures measured by infrared radiation were done 767 times with an average temperature of 34.6 degrees C. Average was 34-35 C, with standard deviation of 1-2 degrees C. Maximal temperature was 40 degrees C and minimal 29 degrees C. There were no adverse effects. This study shows that EnAbl system is an efficacious method.

Catheter Ablation↗

Endometrial Ablation with the EnAbl System

We assessed the safety of a new method of endometrial ablation using heated saline in 11 patients who were undergoing elective hysterectomy. The EnAbl system consists of a controller, computer, and disposable, flexible probe that provides in situ heating and circulation of the saline while maintaining a tight seal at the internal os. The system's low pressure precluded ligation of the oviducts. Temperatures of the saline, uterine serosa, subserosa, and oviducts were monitored throughout the 15-minute procedure in all 10 treatments and 1 control. Histology revealed an average depth of treatment of 4 mm, including necrosis of the surface myometrium. Average depth of necrosis was consistent throughout the cavity regardless of the presence of insignificant myomas. Serosal, subserosal, and oviduct temperatures remained low (&lte;45° C) during the 10 treatments of 70 to 85° C. We believe that this method provides an efficacious depth of treatment while maintaining safe serosal temperatures.

Journal Article↗