PubMed Health⌕ Search

Biomedical subjects

V K Kumar

Publications and source records attributed to V K Kumar.

24 records · Page 2Linked to original sources

Measurement of intimacy attitudes: the Intimacy Attitude Scale--revisited.

The study evaluated the reliability and validity of a revised version of the Intimacy Attitude Scale originally developed by Amidon. The Cronbach alpha measure of internal consistency showed alpha values between .78 and .86 in five different groups. The test-retest correlation was .57 which improved to .84 after exclusion of three extreme scores. Validity was examined by correlating with several variables. It was concluded that the revised Intimacy Attitude Scale is a reliable instrument with Some degree of Validity for use in research, diagnosis, and training.

Journal Article↗

Primary pulmonary hypertension: natural history and prognostic factors.

A retrospective cohort study was carried out in 61 patients (30 males, 31 females, age 24.6 +/- 11.8 years) with primary pulmonary hypertension diagnosed by strict clinical and hemodynamic criteria, to obtain an understanding of the natural history and prognostic markers. While 15 patients were alive, 46 patients (76%) had expired during the follow up period. Two, five and ten years survivals were 48%, 32% and 12% respectively. Median survival duration from time of diagnosis was 22 months. The survivors had significantly higher age of onset, cardiac index and significantly lower right atrial mean pressure, right ventricular end diastolic pressure, cardiothoracic ratio from chest rontgenogram and calculated pulmonary vascular resistance as compared to non survivors. While pulmonary artery systolic pressure was not significantly different, pulmonary artery diastolic and pulmonary artery mean pressures were significantly lower in survivors than in non-survivors. Lower New York Heart Association class, right atrial mean pressure < or = 7 mm Hg, right ventricular end diastolic pressure < or = 10 mmHg, cardiac index > 2.5 L/min/m2, pulmonary arterial oxygen saturation > 60%, were associated with significantly longer survival. The degree of pulmonary arterial hypertension had an indirect prognostic effect through the above parameters. Vasodilator therapy did not significantly alter the outcome of patients with primary pulmonary hypertension.

Adult↗

Thrombolytic therapy for prosthetic cardiac valve thrombosis.

During 1992-93 12 patients (5 males, 7 females) with thrombosed prosthetic cardiac valves were treated with streptokinase on 13 occasions (one patient with prosthetic tricuspid valve had two thrombotic episodes). Their age ranged from 14 to 52 years (median 39). Two valves were in aortic position, six in mitral and four in tricuspid position. Eight were Bjork-Shiley prosthesis, three were Medtronic Hall valves and one was a St. Jude Valve. Timing of prosthetic valve thrombosis ranged from 3 months to 12 years after valve replacement surgery. Duration of symptoms due to valve thrombosis ranged from 1-4 months with tricuspid valve thrombosis and 1-14 days with left sided valve thrombosis. Five were in functional class II and four each were in functional class III and class IV. All patients were evaluated by echo Doppler and cine fluoroscopy. Loading dose of streptokinase was 2.5 lakh units in 4 patients and 1 lakh units in 9 patients. Maintenance infusion was at 1000 units/Kg/hour in 11 patients and 1 lakh units/hour in 2 patients. Duration of streptokinase infusion ranged from 3 hr to 38 hr. Thrombolytic therapy was successful (clinical, echo Doppler and fluoroscopy) in 12 out of 13 cases (92%). It was unsuccessful in a patient with valve at tricuspid position in whom infusion had to be stopped after 24 hour due to bleeding gums. One patient developed intracerebral bleed and expired. In conclusion streptokinase therapy is useful for prosthetic cardiac valve thrombosis.

Adolescent↗