Preoperative virtual endoscopy and three-dimensional imaging of the surface landmarks of the internal carotid arteries in trans-sphenoidal pituitary surgery.

In trans-sphenoidal pituitary adenoma surgery the sella turcica is opened between the internal carotid arteries. Three-dimensional image processing methods were applied in this study to avoid the risk of damaging the arteries during the opening of the anterior wall of the sella. By using graphical software it was possible to combine the anatomies of the carotid arteries and the sellar wall into one non-perspective three-dimensional image. With a perspective image (virtual endoscopy), the sphenoid sinus landmarks were presented as if looking through a nasoendoscope. This also facilitated preoperative planning but the non-perspective images, with the carotid arteries marked, were found to be the most useful and suitable for clinical routine. The pituitary tumor itself and its relations with the adjacent structures were best evaluated from magnetic resonance imaging scans but, for the opening of the sellar wall and in the three-dimensional orientation with endoscopy, three-dimensional computerized tomography imaging with the carotid arteries marked was found to be helpful.

Adenoma↗

Initial experience with a wireless personal digital assistant as a teleradiology terminal for reporting emergency computerized tomography scans.

A new type of terminal device, a wireless personal digital assistant (PDA) based on a GSM digital cellular phone, was used to transmit computerized tomography scans of 21 patients to a neuroradiologist. All transmitted images were suitable for a preliminary consultation and in one case a final report could be made. In 18 cases the findings were compatible with the reference film reading performed later and in three cases there were minor differences of no clinical importance. Transmission of a single image lasted 1 min 30 s and the transmission of a complete brain scan (14 images) took on average 21 min. The total process of transmission and interpretation of a brain examination series took on average 40 min. In this pilot study the neuroradiologist gained essential information in 24% of the cases and beneficial information in 62%. The neuroradiologist considered that the image consultation saved a hospital visit in 15 cases (71%). Although PDA technology is at an early stage of development and has numerous limitations, it is likely that future technical improvements will allow easier clinical consultations for neurosurgeons and neurologists.

Adolescent↗

[Imaging the ear].

Explore the source record for details and available documents.

Diagnostic Imaging↗

Digital wireless radiology consultations with a portable computer.

A wireless system for radiological subspecialist consultation based on a portable personal computer and a GSM cellular phone was tested. A link with secure access to the hospital image network was built. A total of 68 emergency computerized tomography (CT) examinations were transmitted. Transmission time via GSM for a single CT image was 1 min and for a complete head scan was 18 min. The transmitted images were acceptable for final diagnosis in 72% of the cases, the rest being acceptable for preliminary diagnosis. The diagnosis from the transmitted images did not change after a later review of the original images in 97% of cases. The wireless link saved a hospital visit by the senior radiologist in 24% of cases. The results show that a remote consultation link can be built with readily available technology and that the technique is useful in radiological subspecialist consultations for CT images.

Adolescent↗

A simple device for the stereoscopic display of 3D CT images.

We describe a simple device for creating true 3D views of image pairs obtained at 3D CT reconstruction. The device presents the images in a slightly different angle of view for the left and the right eyes. This true 3D viewing technique was applied experimentally in the evaluation of complex acetabular fractures. Experiments were also made to determine the optimal angle between the images for each eye. The angle varied between 1 degree and 7 degrees for different observers and also depended on the display field of view used.

Acetabulum↗

Computed tomography data based rapid prototyping model of the temporal bone before cochlear implant surgery.

Rapid prototyping (RP) technique allows automatic fabrication of 3D model parts. This method was applied to make a temporal bone model before cochlear implant surgery. A helical CT scan is used to acquire high resolution data from the middle and the inner ear of the patient. From the scanning data bone structures and soft tissues can be separated because their different grayscale pixel values. By using a guided image processing tool the desired parts of the anatomy can be extracted and 3D data created. The segmented data are processed to the form suitable for creating a high accuracy RP model. The RP model is made in the stereolithography (SLA) process by means of a computer guided HeCd laser beam inducing polymerisation of acrylic solution as it passes layer by layer over the surface of the polymer solution. In this prototype model the anatomy of the temporal bone can be clearly visualised, including, e.g., mastoid cells, tympanic cavity, bony canal of facial nerve, and round and oval windows. The inner ear spaces including vestibule, semicircular canals and cochlear turn are also shaped. The transparent acrylic material allows bonelike mechanical handling. The RP model can be dissected and used in individual surgical planning and simulation prior to cochlear implantation.

Cochlear Implants↗