PubMed Health⌕ Search

Biomedical subjects

V Kuhn

Publications and source records attributed to V Kuhn.

10 recordsLinked to original sources

Gender differences in trabecular bone architecture of the distal radius assessed with magnetic resonance imaging and implications for mechanical competence.

High-resolution magnetic resonance imaging (hrMRI) has recently made it possible to evaluate trabecular bone structure in vivo. Despite obvious gender differences in fracture incidence at the distal radius, little is known about gender differences in trabecular bone microarchitecture and its relationship to the structural strength of the forearm. The aim of this study was to determine trabecular bone structure in the distal radius of elderly women and men and its correlation with failure loads of the distal radius as determined in a fall configuration. Specifically, we tested the hypotheses that structural indices differ between women and men and that they offer information that is independent from BMD for predicting structural strength. Intact right arms were obtained from 73 formalin-fixed cadavers (age 80+/-11 years, 43 women, 30 men). Trabecular structural indices (apparent bone volume fraction [app. BV/TV], trabecular number [app. Tb.N], trabecular separation [app. Tb.Sp], trabecular thickness [app. Tb.Th] and fractal dimension [Frac.Dim]) were assessed in the distal metaphysis, using hrMRI with 156 microm in-plane resolution and proprietary digital image analysis, while BMD was measured with dual X-ray absorptiometry (DXA). Women displayed significantly lower BMD (-29.8%, p <0.001), app. BV/TV (-8.2%, p <0.05) and app. Tb.Th (-10.2%, p <0.001) than men, whereas app. Tb.N, app. Tb.Sp. and fractal dimension did not differ significantly. Structural parameters differed between normal and osteopenic women (BV/TV: -11%, p <0.01; Tb.Th: -8%, p <0.001) and between normal and osteoporotic women BV/TV: -21%, p <0.001; Tb.Th: -16%, p <0.001). App. BV/TV, app. Tb.Th and fractal dimension provided information independent from BMD in the prediction of radial failure loads in multiple regression models. These findings imply that it should be of clinical interest to monitor both bone mass and trabecular microstructure for predicting osteoporotic fracture risk.

Absorptiometry, Photon↗

Comparison of multislice CT arthrography and MR arthrography for the detection of articular cartilage lesions of the elbow.

The objective of this study was to compare the value of multislice CT arthrography and MR arthrography in the assessment of cartilage lesions of the elbow joint. Twenty-six cadaveric elbow specimens were examined with the use of CT arthrography and MR arthrography prior to joint exploration and macroscopic inspection of articular cartilage. Findings at CT and MR arthrography were compared with macroscopic assessments in 104 cartilage areas. At macroscopic inspection, 45 cartilage lesions (six grade 2 lesions, 25 grade 3 lesions, 14 grade 4 lesions) and 59 areas of normal articular cartilage were observed. With macroscopic assessment as the gold standard CT and MR arthrography showed an overall sensitivity/specificity of 80/93% and 78/95% for the detection of cartilage lesions, respectively. Only two of six grade 2 lesions were detected by CT and MR arthrography. For the diagnosis of grade 3 and 4 lesions, the sensitivity/specificity was 87/94% with CT arthrography, and 85/95% with MR arthrography. In an experimental setting multislice CT arthrography and MR arthrography showed a similar performance in the detection of cartilage lesions. Both methods indicated limited value in the diagnosis of grade 2 articular cartilage lesions.

Aged↗

Can geometry-based parameters from pQCT and material parameters from quantitative ultrasound (QUS) improve the prediction of radial bone strength over that by bone mass (DXA)?

The diagnosis of osteoporosis is generally based on the assessment of bone mineral content with dual X-ray absorptiometry (DXA) but does not account for the spatial distribution and inherent material properties of the tissue. Peripheral quantitative computed tomography (pQCT) permits one to measure the compartment-specific density and geometry-based parameters of cortical bone. Quantitative ultrasound (QUS) parameters are associated with material properties of cortical bone. The purpose of this study was to test the hypothesis that pQCT and cortical QUS provide additional information to DXA in predicting structural strength of the distal radius. The intact right arm and the isolated left radius were harvested from 70 formalin-fixed cadavers (age 79+/-11 years). The bone mineral content (BMC) was assessed with DXA at the radial metaphysis and shaft. pQCT was also used at the metaphysis and the shaft, while QUS was employed only at the shaft. The failure loads of the radius were assessed by use of a 3-point bending test (isolated radius) and a complex fall simulation (intact arm). The BMC (DXA) displayed a correlation of r=0.96 with the failure moments in 3-point bending ( P<0.001). The correlation between failure load and geometry-based parameters (pQCT) ranged from r=0.85 to r=0.96 and was r=0.64 for the speed of sound (QUS) ( P <0.001). Cortical thickness (pQCT) improved the prediction marginally (r=0.964) in combination with DXA. For the fall simulation, the correlation coefficients were r=0.76 for BMC (DXA) of the shaft, r=0.83 for metaphyseal bone content (pQCT), r=0.55 for QUS, and ranged from r=0.59 to r=0.74 for geometry-based parameters at the shaft (pQCT). pQCT and QUS parameters provided no significant improvement versus DXA alone. Measurement of bone mass by DXA or pQCT thus appears to be sufficient as a surrogate of mechanical strength and fracture risk of the distal radius.

Absorptiometry, Photon↗

Technical considerations for microstructural analysis of human trabecular bone from specimens excised from various skeletal sites.

The purpose of this study was to test the effect of repositioning, systematic displacements of the region of interest (ROI), and acquisition parameters (scan mode and integration time) on quantitative analysis of human trabecular bone microstructure at various skeletal sites, using microcomputed tomographic (microCT) technology. We investigated 28 cylindrical specimens of human trabecular bone (length 14 mm, diameter 8 mm) from four skeletal sites (femoral neck, greater trochanter, second lumbar vertebra, and distal radius). These specimens were selected from over 200 microCT measurements, in order to cover a large range of bone volume fraction (BV/TV) observed at each site. Cylindrical ROIs (length 6 mm, diameter 6 mm) were examined twice at an isotropic resolution of 26 microm, 8 weeks apart. In addition, comparative analyses were performed for displacements of the volumes of interest (VOIs) by 1, 2, 3, and 4 mm (83.4%, 66.6%, 50%, and 33.3% overlap), respectively. Eventually, comparative measurements were obtained at different resolution scan modes and integration times. The results show that microCT measurements are highly reproducible (range of the root mean square coefficient variation % (RMS CV%) = 0.64% to 1.29% for BV/TV at different sites). Displacements of the VOI of up to 4 mm generally led to non significant systematic differences in mean values of < 10%. When comparing various combinations of resolution scan modes and integration times, the use of an integration time of 100 ms was found to be preferable for determining microstructural parameters from human samples with this microCT scanner.

Aged↗

[Tractive force measurement in bone transport--an in vivo investigation in humans].

Bone transport applying the principle of distraction osteogenesis makes it possible to reconstruct long bone defects caused by trauma or resection of bone tumors. The method employing a central cable, developed in Munich, is especially suitable for such applications. The main bone fragments are stabilized by an external fixateur, and bone transport is effected with a single central cable fixed to the tip of the segment, and driven by an external, programmable motor. In 15 patients the tractive forces during the entire bone transport were measured with a strain gauge incorporated within the cable. On the basis of the force profiles characteristics normal bone transport (forces between 150-250 N) can be distinguished from a critical transport (forces > 250 N) with the risk of premature consolidation. There is some evidence that at a very high level of force, just before premature consolidation a very effective form of bone transport with good bone neoformation can be achieved. Transport systems employing a central cable allow this special form of distraction osteogenesis, since there is continuous force monitoring, and there is the option of employing the traction force as a control factor in a loop.

Adolescent↗

Mechanical strength of the proximal femur as predicted from geometric and densitometric bone properties at the lower limb versus the distal radius.

This experimental study compares geometric and densitometric properties of cortical and trabecular bone at the lower limb and the distal radius with those at the femoral neck, and evaluates their ability to predict mechanical failure loads of the proximal femur. One hundred five cadavers were examined with peripheral quantitative computed tomography (LpQCT), with measurements being performed in situ at the distal radius (4%, 20%, 33%), at the distal and proximal tibia, at the tibial and femoral shaft, and at the distal femur. Ex situ measurements were obtained at the femoral neck and at the proximal femoral shaft. Pairs of femora were mechanically tested in a vertical loading and a side impact (fall) configuration. The total (cross-sectional) bone mineral content and trabecular density, but not the cortical properties, displayed a higher association between the femoral neck and the peripheral lower limb than between the neck and the distal radius. Approximately 50%-60% of the variability of femoral failure loads (and >80% of trochanteric side impact fractures) were predicted by in vitro measurements at the neck. Geometric cortical parameters and density contributed independently and significantly to femoral strength. Measurements at the peripheral skeleton explained, however, only 30%-45% of the variability of femoral failure, with no significant difference between the lower limb and the distal radius. At peripheral sites, a combination of geometric and densitometric variables was slightly superior to bone mineral content alone in predicting failure in vertical loading, but this was less evident for cervical side impact fractures. The results show that a stronger association of total bone mineral content and trabecular density between the femoral neck and the lower limb does not translate into improved prediction of femoral strength from measurements at the lower limb vs. those at the distal radius.

Aged↗

Mechanical strength of the thoracolumbar spine in the elderly: prediction from in situ dual-energy X-ray absorptiometry, quantitative computed tomography (QCT), upper and lower limb peripheral QCT, and quantitative ultrasound.

The objective of this study was to compare the ability of clinically available densitometric measurement techniques for evaluating vertebral strength in elderly individuals. Measurements were related to experimentally determined failure strength in the thoracic and lumbar spine. In 127 specimens (82 women and 45 men, age 80 +/- 10 years), dual-energy X-ray absorptiometry (DXA) was performed at the lumbar spine, femur, radius, and total body, and peripheral-quantitative computed tomography (pQCT) at the distal radius, tibia, and femur under in situ conditions with intact soft tissues. Spinal QCT and calcaneal ultrasound parameters were performed ex situ in degassed specimens. Mechanical failure loads of thoracic vertebrae 6 and 10 (T-6 and -10), and lumbar vertebra 3 (L-3) were determined in axial compression on functional three-segment units. In situ anteroposterior DXA and QCT of the lumbar spine explained approximately 65% of the variability of thoracolumbar failure. A combination of cortical and trabecular density (QCT) provided the best prediction in the lumbar spine. However, this was not the case in the thoracic spine, for which lumbar cortical density (QCT) and DXA provided significantly better estimates than trabecular density (QCT). pQCT was significantly less correlated with the strength of lumbar and thoracic vertebrae (r(2) = 40%), but was equivalent to femoral or radial DXA. pQCT measurements in the lower limb showed no advantage over those at the distal radius. Ultrasound explained approximately 25% of the variability of vertebral failure strength and added independent information to spinal QCT, but not to spinal DXA. These experimental results advocate site-specific assessment of vertebral strength by either spinal DXA or QCT.

Absorptiometry, Photon↗

Correlation of thoracic and lumbar vertebral failure loads with in situ vs. ex situ dual energy X-ray absorptiometry.

In this study we explore the hypothesis that estimates of failure loads in the thoracic spine by lumbar dual energy X-ray absorptiometry (DXA) are compromised of skeletal heterogeneity throughout the spine and artifacts of spinal DXA. We studied the correlation between mechanical failure loads of thoracic and lumbar vertebrae, and that of in situ vs. ex situ lumbar DXA with thoracic and lumbar fracture loads, respectively. One hundred and nineteen subjects (76 female, age 82+/-9yr; 43 male, age 77+/-11yr) were examined under in situ conditions (anterior-posterior direction), the scans being repeated ex situ (lateral projection) in 68 cases. The failure loads of thoracic vertebrae (T) 6 and 10, and lumbar vertebra (L) 3 were determined in axial compression, using a functional 3-segment unit. The correlation between thoracic failure loads (T6 vs. T10) was significantly (p<0.01) higher (r=0.85) than those between thoracic and lumbar vertebrae (r=0.68 and 0.61, respectively). Lateral ex situ DXA displayed a significantly higher correlation (p<0.05) with lumbar vertebral fracture loads than in situ anterior-posterior DXA (r=0.85 vs. 0.71), but the correlation of thoracic failure loads with lateral ex situ lumbar DXA was similar to that obtained in situ in anterior-posterior direction (r=0.69 vs. 0.69 for T10, and r=0.61 vs. 0.65 for T6). The correlation between fracture loads of different spinal segments, and between DXA and failure loads was not significantly different between men and women. The results demonstrate a substantial heterogeneity of mechanical competence throughout the spine in elderly individuals. Because of the high incidence of fractures in the thoracic spine, these findings suggest that, clinically, lateral DXA involves no relevant advantage over anterior-posterior measurements of the lumbar spine.

Absorptiometry, Photon↗

[Modification of lymphoblastic transformation by estradiol, progesterone and corticosterone in vitro].

17 beta-Estradiol (E2) and progesterone were tested in vitro for their ability to act as anti-glucocorticoids in thymus and spleen cell cultures of ovariectomized female Lewis rats. Initially, the immunosuppressive effect of corticosterone was verified and both sex steroids were also found to inhibit mitogenic, antigenic and allogeneic lymphoblast transformation although at concentrations higher than those for corticosterone. The suppressive activities were stronger in thymocyte than splenocyte cultures. On the other side, E2 significantly enhanced lymphoblast transformation at concentrations of 10(-9) to 10(-7) mol per litre while progesterone had only moderately increasing effects. Combination of corticosterone with progesterone or both sex steroids resulted in significantly elevated 3Tdr incorporation of mitogen-stimulated thymocytes compared to cultures incubated with corticosterone alone while in splenocyte cultures only the mixed lymphocyte reaction showed similar effects. No synergy between E2 and progesterone in counteracting corticosterone-induced inhibition of lymphocyte proliferation has been observed. In conclusion, corticosterone, E2 and progesterone showed a dose-dependent influence on lymphoblast transformation of thymocytes and splenocytes and progesterone had opposite effects on corticosterone-induced suppression of blastogenesis in rat lymphocytes, especially in thymocytes.

Animals↗