PubMed Health⌕ Search

Biomedical subjects

V L Coen

Publications and source records attributed to V L Coen.

At least 19 recordsLinked to original sources

Endovascular brachytherapy for the prevention of restenosis after femoropopliteal angioplasty. Results of the VARA Trial.

AIM: Endovascular brachytherapy (EBT) has been proposed as a method to prevent restenosis. We performed a prospective randomised multicenter study to determine its efficacy for prophylaxis of restenosis after femoropopliteal percutaneous transluminal angioplasty (PTA). METHODS: Patients with symptomatic stenotic or totally occluding lesions in the femoropopliteal artery were randomised to be treated with PTA plus EBT or PTA alone. In case of EBT, 14 Gy was applied by an 192Ir source to the vessel wall. Clinical examination, ankle-brachial pressure index (ABPI) and duplex ultrasound were planned after 6 and 12 months. The primary endpoint was significant restenosis of the treated segment at duplex ultrasound after 12 months. RESULTS: Fifty-three of the 60 patients who eventually met the inclusion criteria could be studied. After 12 months, restenosis rates were 44% (12/27) in the PTA group versus 35% (8/23) in the PTA + EBT group (c2 test, P=0.51). There was no difference in mandatory reintervention between the 2 groups. Overall, EBT resulted in an absolute risk reduction of significant restenosis of 9%, yet in patients with totally occlusive disease this reduction was 32%. CONCLUSIONS: This study suggests an effect of EBT on the occurrence of restenosis only after PTA of occluded femoropopliteal lesions. Due to a too small number of patients analysed this difference is not statistically significant.

Adult↗

"Edge Effect" of (32)p radioactive stents is caused by the combination of chronic stent injury and radioactive dose falloff.

BACKGROUND: Radioactive stents have been reported to reduce in-stent neointimal thickening. An unexpected increase in neointimal response was observed, however, at the stent-to-artery transitions, the so-called "edge effect." To investigate the factors involved in this edge effect, we studied stents with 1 radioactive half and 1 regular nonradioactive half, thereby creating a midstent radioactive dose-falloff zone next to a nonradioactive stent-artery transition at one side and a radioactive stent-artery transition at the other side. METHODS AND RESULTS: Half-radioactive stents (n=20) and nonradioactive control stents (n=10) were implanted in the coronary arteries of Yucatan micropigs. Animals received aspirin and clopidogrel as antithrombotics. After 4 weeks, a significant midstent stenosis was observed by angiography in the half-radioactive stents. Two animals died suddenly because of coronary occlusion at this mid zone at 8 and 10 weeks. At 12-week follow-up angiography, intravascular ultrasound and histomorphometry showed a significant neointimal thickening at the midstent dose-falloff zone of the half-radioactive stents, but not at the stent-to-artery transitions at both extremities. Such a midstent response (mean angiographic late loss 1.0 mm) was not observed in the nonradioactive stents (mean loss 0.4 to 0.6 mm; P< 0.01). CONCLUSIONS: The edge effect of high-dose radioactive stents in porcine coronary arteries is associated with the combination of stent injury and radioactive dose falloff.

Animals↗

Clinical and angiographical follow-up after implantation of a 6--12 microCi radioactive stent in patients with coronary artery disease.

AIMS: This study is the contribution by the Thoraxcenter, Rotterdam, to the European(32)P Dose Response Trial, a non-randomized multicentre trial to evaluate the safety and efficacy of the radioactive Isostent in patients with single coronary artery disease. METHODS AND RESULTS: The radioactivity of the stent at implantation was 6--12 microCi. All patients received aspirin indefinitely and either ticlopidine or clopidogrel for 3 months. Quantitative coronary angiography measurements of both the stent area and the target lesion (stent area and up to 5 mm proximal and distal to the stent edges) were performed pre- and post-procedure and at the 5-month follow-up. Forty-two radioactive stents were implanted in 40 patients. Treated vessels were the left anterior descending coronary artery (n=20), right coronary artery (n=10) or left circumflex artery (n=10). Eight patients received additional non-radioactive stents. Lesion length measured 10+/-3 mm with a reference diameter of 3.07+/-0.69 mm. Minimal lumen diameter increased from 0.98+/-0.53 mm pre-procedure to 2.29+/-0.52 mm (target lesion) and 2.57+/-0.44 mm (stent area) post-procedure. There was one procedural non-Q wave myocardial infarction, due to transient thrombotic closure. Thirty-six patients returned for angiographical follow-up. Two patients had a total occlusion proximal to the radioactive stent. Of the patent vessels, none had in-stent restenosis. Edge restenosis was observed in 44%, occurring predominantly at the proximal edge. Target lesion revascularization was performed in 10 patients and target vessel revascularization in one patient. No additional clinical end-points occurred during follow-up. The minimal lumen diameter at follow-up averaged 1.66+/-0.71 mm (target lesion) and 2.12+/-0.72 (stent area); therefore late loss was 0.63+/-0.69 (target lesion) and 0.46+/-0.76 (stent area), resulting in a late loss index of 0.65+/-1.15 (target lesion) and 0.30+/-0.53 (stent area). CONCLUSION: These results indicate that the use of radioactive stents is safe and feasible, however, the high incidence of edge restenosis makes this technique currently clinically non-applicable.

Adult↗

Three-dimensional intravascular ultrasound assessment of noninjured edges of beta-irradiated coronary segments.

BACKGROUND: The "edge effect," late lumen loss at the margins of the treated segment, has become an important issue in the field of coronary brachytherapy. The aim of the present study was to assess the edge effect in noninjured margins adjacent to the irradiated segments after catheter-based intracoronary beta-irradiation. METHODS AND RESULTS: Fifty-three vessels were assessed by means of 3-dimensional intravascular ultrasound after the procedure and at 6- to 8-month follow-up. Fourteen vessels (placebo group) did not receive radiation (sham source), whereas 39 vessels were irradiated. In the irradiated group, 48 edges (5 mm in length) were identified as noninjured, whereas 18 noninjured edges were selected in the placebo group. We compared the volumetric intravascular ultrasound measurements of the noninjured edges of the irradiated vessels with the fully irradiated nonstented segments (IRS, n=27) (26-mm segments received the prescribed 100% isodose) and the noninjured edges of the vessels of the placebo patients. The lumen decreased (6 mm(3)) in the noninjured edges of the irradiated vessels at follow-up (P:=0. 001). We observed a similar increase in plaque volume in all segments: noninjured edges of the irradiated group (19.6%), noninjured edges of the placebo group (21.5%), and IRS (21.0%). The total vessel volume increased in the IRS in the 3 groups. No edge segment was subject to repeat revascularization. CONCLUSIONS: The edge effect occurs in the noninjured margins of radiation source train in both irradiated and placebo patients. Thus, low-dose radiation may not play an important role in this phenomenon, whereas nonmeasurable device injury may be considered a plausible alternative explanation.

Angioplasty, Balloon↗

Geographic miss: a cause of treatment failure in radio-oncology applied to intracoronary radiation therapy.

BACKGROUND: A recognized limitation of endovascular beta-radiation therapy is the development of new stenosis at the edges of the irradiated area. The combination of injury and low-dose radiation may be the precursor of this phenomenon. We translated the radio-oncological concept of "geographic miss" to define cases in which the radiation source did not fully cover the injured area. The aims of the study were to determine the incidence and causes of geographic miss and evaluate the impact of this inadequate treatment on the outcome of patients treated with intracoronary beta-radiation. METHODS AND RESULTS: We analyzed 50 consecutive patients treated with beta-radiation after percutaneous coronary intervention. The prescribed dose ranged between 12 and 20 Gy at 2 mm from the source axis. By means of quantitative coronary angiography, the irradiated segment (IRS) and both edges were studied before and after intervention and at 6-month follow-up. Edges that were injured during the procedure constituted the geographic miss edges. Twenty-two edges were injured during the intervention, mainly because of procedural complications that extended the treatment beyond the margins of the IRS. Late loss was significantly higher in geographic miss edges than in IRSs and uninjured edges (0.84+/-0.6 versus 0.15+/-0.4 and 0.09+/-0.4 mm, respectively; P<0.0001). Similarly, restenosis rate was significantly higher in the injured edges (10% within IRS, 40.9% in geographic miss edges, and 1.9% in uninjured edges; P<0.001). CONCLUSIONS: These data support the hypothesis that the combination of injury and low-dose beta-radiation induces deleterious outcome.

Angioplasty, Balloon, Coronary↗

Residual plaque burden, delivered dose, and tissue composition predict 6-month outcome after balloon angioplasty and beta-radiation therapy.

BACKGROUND: Inhomogeneity of dose distribution and anatomic aspects of the atherosclerotic plaque may influence the outcome of irradiated lesions after balloon angioplasty (BA). We evaluated the influence of delivered dose and morphological characteristics of coronary stenoses treated with beta-radiation after BA. METHODS AND RESULTS: Eighteen consecutive patients treated according to the Beta Energy Restenosis Trial 1.5 were included in the study. The site of angioplasty was irradiated with the use of a beta-emitting (90)Sr/(90)Y source. With the side branches used as anatomic landmarks, the irradiated area was identified and volumetric assessment was performed by 3D intracoronary ultrasound imaging after treatment and at 6 months. The type of tissue, the presence of dissection, and the vessel volumes were assessed every 2 mm within the irradiated area. The minimal dose absorbed by 90% of the adventitial volume (D(v90)Adv) was calculated in each 2-mm segment. Diffuse calcified subsegments and those containing side branches were excluded. Two hundred six coronary subsegments were studied. Of those, 55 were defined as soft, 129 as hard, and 22 as normal/intimal thickening. Plaque volume showed less increase in hard segments as compared with soft and normal/intimal thickening segments (P<0.0001). D(v90)Adv was associated with plaque volume at follow-up after a polynomial equation with linear and nonlinear components (r = 0.71; P = 0.0001). The multivariate regression analysis identified the independent predictors of the plaque volume at follow-up: plaque volume after treatment, D(v90)Adv, and type of plaque. CONCLUSIONS: Residual plaque burden, delivered dose, and tiss composition play a fundamental role in the volumetric outcome at 6-month follow-up after beta-radiation therapy and BA.

Angioplasty, Balloon, Coronary↗

Relationship between tensile stress and plaque growth after balloon angioplasty treated with and without intracoronary beta-brachytherapy.

AIMS: We investigated the influence of tensile stress on plaque growth after balloon angioplasty with and without beta-radiation therapy. METHODS AND RESULTS: Thirty-one consecutive patients successfully treated with balloon angioplasty were analysed qualitatively and quantitatively by means of an ECG-gated three-dimensional intravascular ultrasound post-procedure and at follow-up. Eighteen patients were irradiated with catheter-based beta-radiation ((90)Sr/(90)Y source) and 13 were not (control). Studied segments were divided into 2 mm subsegments. Thus 184 irradiated and 111 non-irradiated subsegments were included. Tensile stress was calculated according to Laplace's law. The radiation dose was calculated by means of dose-volume histograms. Plaque growth was positively correlated to tensile stress in both the radiation and control groups (r=0.374, P=0.0001 and r=0.305, P=0.001). Low-dose subsegments (<6 Gy) had a significant correlation (r=0.410, P=0.0001) whereas no correlation was observed in the effective-dose subsegments (> or = 6 Gy). Multivariate analysis identified tensile stress as the only independent predictor of plaque increase in non-irradiated subsegments, whereas actual dose and plaque morphology were stronger predictors in irradiated subsegments. CONCLUSION: The results of this study suggest that plaque growth is related to tensile stress after balloon angioplasty. Intracoronary brachytherapy may alter the biophysical process on plaque growth when the prescribed dose is effectively delivered.

Aged↗

Outcome from balloon induced coronary artery dissection after intracoronary beta radiation.

OBJECTIVE: To evaluate the healing of balloon induced coronary artery dissection in individuals who have received beta radiation treatment and to propose a new intravascular ultrasound (IVUS) dissection score to facilitate the comparison of dissection through time. DESIGN: Retrospective study. SETTING: Tertiary referral centre. PATIENTS: 31 patients with stable angina pectoris, enrolled in the beta energy restenosis trial (BERT-1.5), were included. After excluding those who underwent stent implantation, the evaluable population was 22 patients. INTERVENTIONS: Balloon angioplasty and intracoronary radiation followed by quantitative coronary angiography (QCA) and IVUS. Repeat QCA and IVUS were performed at six month follow up. MAIN OUTCOME MEASURES: QCA and IVUS evidence of healing of dissection. Dissection classification for angiography was by the National Heart Lung Blood Institute scale. IVUS proven dissection was defined as partial or complete. The following IVUS defined characteristics of dissection were described in the affected coronary segments: length, depth, arc circumference, presence of flap, and dissection score. Dissection was defined as healed when all features of dissection had resolved. The calculated dose of radiation received by the dissected area in those with healed versus non-healed dissection was also compared. RESULTS: Angiography (type A = 5, B = 7, C = 4) and IVUS proven (partial = 12, complete = 4) dissections were seen in 16 patients following intervention. At six month follow up, six and eight unhealed dissections were seen by angiography (A = 2, B = 4) and IVUS (partial = 7, complete = 1), respectively. The mean IVUS dissection score was 5.2 (range 3-8) following the procedure, and 4.6 (range 3-7) at follow up. No correlation was found between the dose prescribed in the treated area and the presence of unhealed dissection. No change in anginal status was seen despite the presence of unhealed dissection. CONCLUSION: beta radiation appears to alter the normal healing process, resulting in unhealed dissection in certain individuals. In view of the delayed and abnormal healing observed, long term follow up is indicated given the possible late adverse effects of radiation. Although in this cohort no increase in cardiac events following coronary dissections was seen, larger populations are needed to confirm this phenomenon. Stenting of all coronary dissections may be warranted in patients scheduled for brachytherapy after balloon angioplasty.

Angina Pectoris↗

The effect of 32P beta-radiotherapy on both vessel remodeling and neointimal hyperplasia after coronary balloon angioplasty and stenting: a three-dimensional intravascular ultrasound investigation.

Intracoronary radiation is a promising therapy to decrease restenosis after percutaneous intervention. The aim of this pilot study was to determine the mechanism of intracoronary beta-radiation after balloon angioplasty and stenting in a double-blind placebo-controlled randomized fashion. Twenty-six patients were randomized to either placebo (n = 6) or 3 doses (28, 35 and 42 Gy) of beta-radiation (n = 20) using the Guidant brachytherapy system (27 mm long 32P source wire). Of these, 21 patients underwent post-procedure and 6-month follow-up three-dimensional intravascular ultrasound (IVUS) assessment. Volumetric quantification was performed by means of a semi-automated contour detection system after an ECG-gated motorized pullback IVUS imaging and three-dimensional reconstruction. We compared the volumetric changes (Delta) of total vessel volume (TVV), plaque volume (PV) and lumen volume (LV) after 6 months between placebo (dummy wire) and irradiated patients. In addition, the volume of neointimal hyperplasia was quantified within the stented segments. There was an opposite behavior of TVV and LV change between placebo (DeltaTVV = -24 mm3 and DeltaLV = -42 mm3) and irradiated (DeltaTVV = +18 mm3 and (DeltaLV = +5 mm3) patients. The mean neointimal formation within the stented segment in the irradiated patients (n = 7) was 1.9 mm3 (1.5%). Our results suggest that beta-radiation affects vessel remodeling after percutaneous intervention and inhibit neointimal formation in stented patients.

Aged↗

Peripheral vascular brachytherapy: an introduction.

The response of cells to ionising radiation has been extensively studied for the past 30 years. When radiation is absorbed in biological material, it can directly ionise a critical site (direct effect) or interact with other molecules to produce reactive free radicals, which can subsequently damage critical biological molecules (indirect effect). DNA is considered the critical target damaged by ionising radiation by both direct and indirect processes. Since radiotherapy had proven to be effective in the treatment of non-malignant proliferative processes, it was assumed that this adjunctive treatment would also inhibit vascular restenosis. The major difference between external and intravascular radiation is dose distribution. Intravascular delivery results in extremely high doses to the lumen with a fall-off in dose as a function of distance from the source; whereas, external beam would deliver a uniform dose over the entire volume of tissue treated. Unlike in the coronary circulation most of the peripheral vessels treated are greater than 3 mm in diameter; in fact many are 7 to 10 mm in diameter. Since beta radiation is related to lower penetration properties and more heterogeneous distribution of radiation in comparison to gamma radiation, it is therefore necessary to use a gamma radiation source because it would be difficult to irradiate the sub-intimal tissue with a beta source centred in a large vessel. Radiation can and does have the potential to destroy blood vessels. The challenge in vascular brachytherapy is to treat blood vessels to a point where restenosis is inhibited; yet the vessel is not irreparably damaged.

Animals↗

beta-Particle-emitting radioactive stent implantation. A safety and feasibility study.

BACKGROUND: This study represents the Heart Center Rotterdam's contribution to the Isostents for Restenosis Intervention Study, a nonrandomized multicenter trial evaluating the safety and feasibility of the radioactive Isostent in patients with single coronary artery disease. Restenosis after stent implantation is primarily caused by neointimal hyperplasia. In animal studies, beta-particle-emitting radioactive stents decrease neointimal hyperplasia by inhibiting smooth muscle cell proliferation. METHODS AND RESULTS: The radioisotope (32)P, a beta-particle emitter with a half-life of 14.3 days, was directly embedded into the Isostent. The calculated range of radioactivity was 0.75 to 1.5 microCi. Quantitative coronary angiography measurements were performed before and after the procedure and at 6-month follow-up. A total of 31 radioactive stents were used in 26 patients; 30 (97%) were successfully implanted, and 1 was embolized. Treated lesions were in the left anterior descending coronary artery (n=12), the right coronary artery (n=8), or the left circumflex coronary artery (n=6). Five patients received additional, nonradioactive stents. Treated lesion lengths were 13+/-4 mm, with a reference diameter of 2.93+/-0. 47 mm. Minimum lumen diameter increased from 0.87+/-0.28 mm preprocedure to 2.84+/-0.35 mm postprocedure. No in-hospital adverse cardiac events occurred. All patients received aspirin indefinitely and ticlopidine for 4 weeks. Twenty-three patients (88%) returned for 6-month angiographic follow-up; 17% of them had in-stent restenosis, and 13% had repeat revascularization. No restenosis was observed at the stent edges. Minimum lumen diameter at follow-up averaged 1.85+/-0.69 mm, which resulted in a late loss of 0.99+/-0. 59 mm and a late loss index of 0.53+/-0.35. No other major cardiac events occurred during the 6-month follow-up. CONCLUSIONS: The use of radioactive stents with an activity of 0.75 to 1.5 microCi is safe and feasible.

Adult↗

Preserved endothelium-dependent vasodilation in coronary segments previously treated with balloon angioplasty and intracoronary irradiation.

BACKGROUND: Abnormal endothelium-dependent coronary vasomotion has been reported after balloon angioplasty (BA), as well as after intracoronary radiation. However, the long-term effect on coronary vasomotion is not known. The aim of this study was to evaluate the long-term vasomotion of coronary segments treated with BA and brachytherapy. METHODS AND RESULTS: Patients with single de novo lesions treated either with BA followed by intracoronary beta-irradiation (according to the Beta Energy Restenosis Trial-1.5) or with BA alone were eligible. Of these groups, those patients in stable condition who returned for 6-month angiographic follow-up formed the study population (n=19, irradiated group and n=11, control group). Endothelium-dependent coronary vasomotion was assessed by selective infusion of serial doses of acetylcholine (ACh) proximally to the treated area. Mean luminal diameter was calculated by quantitative coronary angiography both in the treated area and in distal segments. Endothelial dysfunction was defined as a vasoconstriction after the maximal dose of ACh (10(-6) mol/L). Seventeen irradiated segments (89.5%) demonstrated normal endothelial function. In contrast, 10 distal nonirradiated segments (53%) and 5 control segments (45%) demonstrated endothelium-dependent vasoconstriction (-19+/-17% and -9.0+/-5%, respectively). Mean percentage of change in mean luminal diameter after ACh was significantly higher in irradiated segments (P=0.01). CONCLUSIONS: Endothelium-dependent vasomotion of coronary segments treated with BA followed by beta-radiation is restored in the majority of stable patients at 6-month follow-up. This functional response appeared to be better than those documented both in the distal segments and in segments treated with BA alone.

Acetylcholine↗

Geometric vascular remodeling after balloon angioplasty and beta-radiation therapy: A three-dimensional intravascular ultrasound study.

BACKGROUND: Endovascular radiation appears to inhibit intimal thickening after overstretching balloon injury in animal models. The effect of brachytherapy on vascular remodeling is unknown. The aim of the study was to determine the evolution of coronary vessel dimensions after intracoronary irradiation after successful balloon angioplasty in humans. METHODS AND RESULTS: Twenty-one consecutive patients treated with balloon angioplasty and beta-radiation according to the Beta Energy Restenosis Trial-1.5 were included in the study. Volumetric assessment of the irradiated segment and both edges was performed after brachytherapy and at 6-month follow-up. Intravascular ultrasound images were acquired by means of ECG-triggered pullback, and 3-D reconstruction was performed by automated edge detection, allowing the calculation of lumen, plaque, and external elastic membrane (EEM) volumes. In the irradiated segments, mean EEM and plaque volumes increased significantly (451+/-128 to 490.9+/-159 mm(3) and 201.2+/-59 to 241.7+/-74 mm(3); P=0.01 and P=0.001, respectively), whereas luminal volume remained unchanged (250.8+/-91 to 249.2+/-102 mm(3); P=NS). The edges demonstrated an increase in mean plaque volume (26.8+/-12 to 32. 6+/-10 mm(3), P=0.0001) and no net change in mean EEM volume (71. 4+/-24 to 70.9+/-24 mm(3), P=NS), resulting in a decrease in mean luminal volume (44.6+/-16 to 38.3+/-16 mm(3), P=0.01). CONCLUSIONS: A different pattern of remodeling is observed in coronary segments treated with beta-radiation after successful balloon angioplasty. In the irradiated segments, the adaptive increase of EEM volume appears to be the major contributor to the luminal volume at follow-up. Conversely, both edges showed an increase in plaque volume without a net change in EEM volume.

Angioplasty, Balloon↗

Late coronary occlusion after intracoronary brachytherapy.

BACKGROUND: Intracoronary brachytherapy appears to be a promising technology to prevent restenosis. Presently, limited data are available regarding the late safety of this therapeutic modality. The aim of the study was to determine the incidence of late (>1 month) thrombosis after PTCA and radiotherapy. METHODS AND RESULTS: From April 1997 to March 1999, we successfully treated 108 patients with PTCA followed by intracoronary beta-radiation. Ninety-one patients have completed at least 2 months of clinical follow-up. Of these patients, 6.6% (6 patients) presented with sudden thrombotic events confirmed by angiography 2 to 15 months after intervention (2 balloon angioplasty and 4 stent). Some factors (overlapping stents, unhealed dissection) may have triggered the thrombosis process, but the timing of the event is extremely unusual. Therefore, the effect of radiation on delaying the healing process and maintaining a thrombogenic coronary surface is proposed as the most plausible mechanism to explain such late events. CONCLUSIONS: Late and sudden thrombosis after PTCA followed by intracoronary radiotherapy is a new phenomenon in interventional cardiology.

Aged↗

Late stent malapposition occurring after intracoronary beta-irradiation detected by intravascular ultrasound.

We report a case of late stent malapposition occurring 6 months after intracoronary beta-irradiation detected by three-dimensional intravascular ultrasound, in spite of good apposition immediately after the procedure. Volumetric quantification revealed that stent volume remained unchanged, whereas total vessel volume increased by 13% after 6 months within the stent area. The increase of the vessel volume took place mainly in the proximal part of the stent, where the malapposition was located.

Angioplasty, Balloon, Coronary↗

Compassionate use of intracoronary beta-irradiation for treatment of recurrent in-stent restenosis.

Recurrent in-stent restenosis after balloon angioplasty poses a serious management problem. Previously g-radiation has been shown to be effective in patients with in-stent restenosis. The aim of the study was to determine the feasibility and safety of b-radiation in patients with recurrent in-stent restenosis. From May 1997 to December 1998, 18 patients were treated with balloon angioplasty (n = 8) or laser (n = 10), followed by intracoronary b-radiation at a prescribed dose of 16 Gray at 2 mm from the source, for reference diameters by quantitative coronary angiography < 3.25 mm or 20 Gray for reference diameters > or =3.25 mm. Vessels treated were as follows: left anterior descending: (n = 5); circumflex: (n = 4); right coronary artery: (n = 6); saphenous vein graft: (n = 3). Average recurrence rate was 2.4 +/- 0.7 and the restenotic length was 16 +/- 7 mm. b-radiation was successfully delivered in all patients. Two patients presented complications related to laser debulking: a non-Q wave myocardial infarction in one and a re-angioplasty due to uncovered distal dissection in another. Geographical miss, defined as an area which has been injured but not covered by the radiation source, was demonstrated in 8 patients. Seventeen patients (94%) completed the 6-month angiographic follow-up. Restenosis (> 50% Diameter Stenosis) was observed in 9 patients (53%), leading to target lesion revascularization in 8 patients (47%). Six of the 9 restenoses were located in areas with geographical miss. Intracoronary b-radiation for recurrent in-stent restenosis appears to be a safe and feasible management strategy. However, the mismatch between injured and irradiated area may lead to failure of this therapy.

Aged↗

Guidance of intracoronary radiation therapy based on dose-volume histograms derived from quantitative intravascular ultrasound.

Application of ionizing radiation to prevent restenosis in atherosclerotic vessels treated by balloon angioplasty is a new treatment under investigation in interventional cardiology and radiology. There is variability in dose prescription, and both gamma- and beta-emitters are used, leading to a wide range of dose distribution over the arterial vessel wall. We present a new modality of dosimetry based on a method that three-dimensional (3-D) image reconstruction of electrocardiogram (ECG)-gated intravascular ultrasound (IVUS) images. Dose volume histograms (DVH) are used to describe the cumulative distribution of dose over two specific volumes: i) at the level of the luminal surface, defined with a thickness of 0.1 mm from the automatically detected contour of the highly echogenic blood-vessel interface, and ii) the adventitia volume is computed considering a 0.5-mm thickness from the echogenic media-adventitia interface. DVH provide a tool for reporting the actual delivered dose at the site believed to be the target: the adventitia, and to detect excessive radiation which could lead to vascular complications. Simulation of a gamma-emitter or of a radioactive source train in the center of the lumen are possible. The data obtained from the first ten patients included in the beta-irradiation trial (BERT 1.5) conducted in our institution are presented, supporting the use of DVH based on quantitative IVUS measurements for optimal dose prescription in vascular interventional radiation therapy.

Brachytherapy↗

Comparison of brachytherapy strategies based on dose-volume histograms derived from quantitative intravascular ultrasound.

PURPOSE: We present in this paper the comparison, by simulation, of different treatment strategies based either on beta- or gamma-sources, both with and without a centering device. Ionizing radiation to prevent restenosis is an emerging modality in interventional cardiology. Numerous clinical studies are presently being performed or planned, but there is variability in dose prescription, and both gamma- and beta-emitters are used, leading to a wide range of possible dose distributions over the arterial vessel wall. This paper discusses the potential merits of dose-volume histograms (DVH) based on three-dimensional (3-D) reconstruction of electrocardiogram (ECG)-gated intravascular ultrasound (IVUS) to compare brachytherapy treatment strategies. MATERIALS AND METHODS: DVH describe the cumulative distribution of dose over three specific volumes: (1) at the level of the luminal surface, a volume was defined with a thickness of 0.1 mm from the automatically detected contour of the highly echogenic blood-vessel interface; (2) at the level of the IVUS echogenic media-adventitia interface (external elastic lamina [EEL]), an adventitial volume was computed considering a 0.5-mm thickness from EEL; and (3) the volume encompassed between the luminal surface and the EEL (plaque + media). The IVUS data used were recorded in 23 of 31 patients during the Beta Energy Restenosis Trial (BERT) conducted in our institution. RESULTS: On average, the minimal dose in 90% of the adventitial volume was 37 +/- 16% of the prescribed dose; the minimal dose in 90% of the plaque + media volume was 58 +/- 24% and of the luminal surface volume was 67 +/- 31%. The minimal dose in the 10% most exposed luminal surface volume was 296 +/- 42%. Simulations of the use of a gamma-emitter and/or a radioactive source train centered in the lumen are reported, with a comparison of the homogeneity of the dose distribution. CONCLUSIONS: It is possible to derive DVH from IVUS, to evaluate the dose delivered to different parts of the coronary wall. This process should improve our understanding of the mechanisms of action of brachytherapy.

Brachytherapy↗