A small punch test technique for characterizing the elastic modulus and fracture behavior of PMMA bone cement used in total joint replacement.

Polymethylmethacrylate (PMMA) bone cement is used in total joint replacements to anchor implants to the underlying bone. Establishing and maintaining the integrity of bone cement is thus of critical importance to the long-term outcome of joint replacement surgery. The goal of the present study was to evaluate the suitability of a novel testing technique, the small punch or miniaturized disk bend test, to characterize the elastic modulus and fracture behavior of PMMA. We investigated the hypothesis that the crack initiation behavior of PMMA during the small punch test was sensitive to the test temperature. Miniature disk-shaped specimens, 0.5 mm thick and 6.4 mm in diameter, were prepared from PMMA and Simplex-P bone cement according to manufacturers' instructions. Testing was conducted at ambient and body temperatures, and the effect of test temperature on the elastic modulus and fracture behavior was statistically evaluated using analysis of variance. For both PMMA materials, the test temperature had a significant effect on elastic modulus and crack initiation behavior. At body temperature, the specimens exhibited "ductile" crack initiation, whereas at room temperature "brittle" crack initiation was observed. The small punch test was found to be a sensitive and repeatable test method for evaluating the mechanical behavior of PMMA. In light of the results of this study, future small punch testing should be conducted at body temperature.

Arthroplasty, Replacement↗

Calcaneal loading during walking and running.

PURPOSE: This study of the foot uses experimentally measured kinematic and kinetic data with a numerical model to evaluate in vivo calcaneal stresses during walking and running. METHODS: External ground reaction forces (GRF) and kinematic data were measured during walking and running using cineradiography and force plate measurements. A contact-coupled finite element model of the foot was developed to assess the forces acting on the calcaneus during gait. RESULTS: We found that the calculated force-time profiles of the joint contact, ligament, and Achilles tendon forces varied with the time-history curve of the moment about the ankle joint. The model predicted peak talocalcaneal and calcaneocuboid joint loads of 5.4 and 4.2 body weights (BW) during walking and 11.1 and 7.9 BW during running. The maximum predicted Achilles tendon forces were 3.9 and 7.7 BW for walking and running. CONCLUSIONS: Large magnitude forces and calcaneal stresses are generated late in the stance phase, with maximum loads occurring at approximately 70% of the stance phase during walking and at approximately 60% of the stance phase during running, for the gait velocities analyzed. The trajectories of the principal stresses, during both walking and running, corresponded to each other and qualitatively to the calcaneal trabecular architecture.

Adult↗

Fatigue testing of cerclage stainless steel wire fixation.

Because wire fixation continues to be used extensively in the practice of orthopaedic surgery, despite a high incidence of wire breakage, understanding the mechanism of this failure is of important clinical interest. The aim of this study was to investigate the failure of cerclage stainless steel wire using an in vitro cyclic loading device. A stainless steel testing fixture consisting of two half cylinders with a combined diameter of 2.5 cm was mounted in a servo hydraulic testing machine. Specimens of number 18 gauge (0.97 mm diameter) and number 16 gauge (1.22 mm diameter) 316L stainless steel wire were mounted around the two half cylinders in a cerclage manner using three different fastening methods: a uniform symmetrical twist, a knot twist, and a square knot. Single-load-to-failure and cyclic load tests were performed under controlled tensile displacement. The cerclage wire system fastened with a twist resulted in failure at loads significantly lower than systems fastened with the knot twist and the square knot. Cyclic loading of the wire fastened with twists also showed decreased fatigue properties when compared to those fastened with the knot twist and the square knot. In all tests, the 16-gauge wire was found to be clearly superior to the 18-gauge wire. For both wires, fatigue strengths at 100,000 cycles were only 30-37% of the static ultimate strength. These results show that wire diameter and fastening system are two important factors affecting the mechanical properties of the resulting fixation.

Bone Wires↗