PubMed Health⌕ Search

Biomedical subjects

V M Tronnier

Publications and source records attributed to V M Tronnier.

34 records · Page 2Linked to original sources

Pallidal stimulation for generalized dystonia. Report of three cases.

Pallidal stereotactic surgery is a well-accepted treatment alternative for Parkinson's disease. Another indication for this procedure is medically refractory dystonia, especially generalized dystonia with abnormal axial and extremity movements and postures. Improvement of dystonia after pallidotomy has been reported in several recent papers. In this report the authors describe three patients with generalized dystonia (two primary, one secondary) and their improvement after bilateral pallidal stimulation at follow-up times of between 6 and 18 months.

Adolescent↗

Magnetic resonance imaging with implanted neurostimulators: an in vitro and in vivo study.

OBJECTIVE: The goal was to assess the safety of magnetic resonance imaging (MRI) with implanted neurostimulators, in an in vitro and in vivo study. METHODS: Two different implantable pulse generators (IPGs) (ITREL II and 3; Medtronic, Minneapolis, MN) and different leads (separately and connected to an IPG) were tested in three different MRI scanners (0.2, 0.25, and 1.5 T). Measurements of the induced voltages (using an external oscilloscope) and the induced heat (using an infrared camera) were performed in an in vitro study. Finally, 38 patients with implanted neurostimulator systems (leads and IPGs) underwent MRI in 50 examinations, with continuous monitoring by a physician with uninterrupted visual and vocal contact with the patient. Twenty-five patients were studied prospectively, with documented printouts of the parameter settings before and after MRI. RESULTS: An induced voltage of 2.4 to 5.5 V was measured in the experimental configuration with a lead connected to an IPG. The voltage was higher with the leads alone, compared with the leads connected to the IPG, and was dependent on the MRI scanner, the sequences, and the type of lead. No heat induction was observed in any part of the hardware. No change of pulse shape or change of IPG parameters was observed during MRI. No adverse effects occurred in patients with chronically implanted deep brain leads connected to an IPG. CONCLUSION: MRI can be safely performed in patients with implanted neurostimulation systems with the tested deep brain leads connected to an IPG (ITREL II and 3), with running parameters. No heat induction was detected, and the experimentally measured induced voltage did not seem to harm the patients. Only the reed switch of the IPGs was activated; the other parameters remained unchanged. Further investigations must be performed to study the local electrical effects in larger plate electrodes; these effects might cause slight discomfort. There is no danger with any type of electrode during MRI examinations if the electrodes lie outside the region of interest. These observations are restricted to the tested devices. A conscientious estimation of the risks and benefits of MRI for patients with implanted devices is recommended. If the type of device is not known to the examiner, MRI should still be considered to be contraindicated.

Brain Diseases↗

Intraoperative MR imaging increases the extent of tumor resection in patients with high-grade gliomas.

BACKGROUND AND PURPOSE: MR is being used increasingly as an intraoperative imaging technique. The purpose of this study was to test the hypothesis that intraoperative MR imaging increases the extent of tumor resection, thus improving surgical results in patients with high-grade gliomas. METHODS: Thirty-eight patients with intracranial high-grade gliomas underwent 41 operations. Using a neuronavigation system, tumors were resected in all patients to the point at which the neurosurgeon would have terminated the operation because he thought that all enhancing tumor had been removed. Intraoperative MR imaging (0.2 T) was performed, and surgery, if necessary and feasible, was continued. All patients underwent early postoperative MR imaging (1.5 T). By comparing the proportions of patients in whom complete resection of all enhancing tumor was shown by intraoperative and early postoperative MR imaging, respectively, the impact of intraoperative MR imaging on surgery was determined. RESULTS: Intraoperative MR imaging showed residual enhancing tumor in 22 cases (53.7%). In 15 patients (36.6%), no residual tumor was seen, whereas the results of the remaining four intraoperative MR examinations (9.7%) were inconclusive. In 17 of the 22 cases in which residual tumor was seen, surgery was continued. Early postoperative MR imaging showed residual tumor in eight patients (19.5%) and no residual tumor in 31 cases (75.6%); findings were uncertain in two patients (4.9%). The difference in the proportion of "complete removals" was statistically highly significant (P = .0004). CONCLUSION: Intraoperative MR imaging significantly increases the rate of complete tumor removal. The rate of complete removal of all enhancing tumor parts was only 36.6% when neuronavigation alone was used, which suggests the benefits of intraoperative imaging.

Adult↗

[Neuronavigation. Methods and prospects].

With the recent developments in computer technology and the improvements in modern neuroimaging, frame-based stereotactic guidance for open microsurgical procedures has been increasingly replaced by neuronavigation, also called frameless stereotaxy. It allows transfer of individual patientís images onto the operative field to assist the neurosurgeon intraoperatively in defining the tumor margins or identifying functionally important brain areas. The different localization techniques employed are articulated position-sensing arms, infrared or ultrasound systems working with the principle of satellite navigation and robotic systems integrated with the operating microscope. In 200 operations performed with different systems (arm-based, robotic and infrared) the method proved to be helpful, enabling fewer invasive procedures to be performed. With a mean deviation of 2.87 +/- 1.9 mm for intraoperative localization, the accuracy was only slightly worse than in frame-based stereotaxy with deviations below 2 mm. Neuronavigation was most helpful for operations on deeply seated lesions, skull-base tumors and lesions in brain areas with high functionality. The major disadvantage is the use of preoperative data for navigation, leading to inaccuracies when anatomical structures are altered during the operation by resection of tumors or shift of intracranial soft tissue. Intraoperative magnetic resonance imaging (MRI) might be a solution for this problem. With the method of intraoperative MRI developed in our department it has already been possible to update neuronavigation with images reflecting intraoperative changes in anatomy. Therefore, neuronavigation is definitely a method with growing importance in operative routine, and it will also spread into other surgical specialties.

Brain Diseases↗

[Intraoperative magnetic resonance tomography for control of extent of neurosurgical operations].

PURPOSE: The main aim of our study was to find out whether the combined use of neuronavigation and intraoperative MRI can increase the rate of "complete tumor removal". The second aim was to characterize the different forms of surgically induced enhancement in order to differentiate them from residual tumor. MATERIALS AND METHODS: Surgery was performed in 18 patients with high-grade glioma. Using a neuronavigation device, the surgeons operated up to the point where they would otherwise have terminated surgery. Intraoperative MRI was then performed to determine whether residual enhancing had been left behind and to update the neuronavigation device. If necessary, feasible surgery was continued. On days 1-3 after surgery early postoperative MRI (1.5 T) was performed. The proportion of patients in whom the enhancing tumor was completely removed was compared with a series of 60 patients with glioblastoma multiforme, who had been operated on using neither neuronavigation nor intraoperative MRI. We also looked for and characterized different types of surgically induced enhancement. RESULTS: Intraoperative MRI definitely showed residual tumor in 6 of the 18 patients and resulted in ambiguous findings in 3 patients. In 7 patients surgery was continued. Early postoperative MRI showed residual tumor in 3 patients and resulted in uncertain findings in 2 patients. The rate of patients in whom complete removal of enhancing tumor could be achieved was 50% at the time of the intraoperative MR examination and 72% at the time of the early postoperative MR control. The difference in proportion of patients with "complete tumor removal" between the groups who had been operated on using neuronavigation (NN) and intraoperative MRI (ioMRI) and those who had been operated on using only modern neurosurgical techniques except NN and ioMRI was statistically highly significant (Fisher exact test; P = 0.008). Four different types of surgically induced contrast enhancement were observed. These phenomena carry different confounding potentials with residual tumor. CONCLUSION: Our preliminary experience with intraoperative MRI in patients with enhancing intraaxial tumors is encouraging. Combined use of neuronavigation and intraoperative MRI was able to increase the proportion of patients in whom complete removal of the enhancing parts of the tumor was achieved. Surgically induced enhancement requires careful analysis of the intraoperative MRI in order not to confuse it with residual tumor.

Astrocytoma↗

Modified Headholder and operating table for intra-operative MRI in neurosurgery.

In order to facilitate intra-operative use of magnetic resonance imaging (MRI) in neurosurgery an MRI-compatible headholder was developed and adapted to a modified MR-couch simultaneously serving as tabletop for the operating table. To allow shock-free transport into the scanner the wheels of the operating table were replaced by an air cushion mechanism. In 75 procedures the system proved to be reliable and safe. Image quality was not impaired by the fixation device. With growing routine the transfer became straightforward, requiring approximately 10 min. Intra-operative MRI is thus made possible with minimal changes to the standard surgical environment. Its benefit however, still remains to be critically investigated.

Equipment Design↗

Neuronavigation--first experiences with three different commercially available systems.

Growing interest in neuronavigation also referred to as frameless stereotaxy has led to the development of various navigational devices employing different localization methods. In 152 procedures the authors have used neuronavigation. Cases included 89 intracranial- and 26 skull base tumours, 9 biopsies, 21 vascular and 7 functional procedures on 144 patients since July 1993. In 75 cases the lesions were located in eloquent areas. In 82% (124) MRI, 13% (18) CT and 5% (8) both imaging methods were employed. Three neuronavigational devices with different localization methods were used for the procedures. The Viewing Wand (VW, ISG, Canada), a multijointed arm was used in 101 procedures. In 15 cases the SPOCS (Aesculap, Germany) consisting of cameras detecting infrared light from LED's mounted on instruments and in 51 cases the microscope-integrated MKM (ZEISS, Germany) was investigated, 15 times two systems were used simultaneously. Mean time necessary for preoperative registration was 23 +/- 13 min (VW), 21 +/- 16 min (SPOCS) and 27 +/- 22 min (MKM) respectively. The mean accuracy of registration measured as RMS was 2.9 +/- 1.2 mm (VW), 3.3 +/- 0.9 mm (SPOCS) and 3.1 +/- 1.0 (MKM) respectively. Regarding intraoperative handling the VW was found to be a robust but sometimes bulky and hindering device whereas the SPOCS was more flexible but with the need of unobstructed visibility between cameras and pointers. The MKM without these restrictions required training to get used to handling.

Adolescent↗

Pallidal stimulation: an alternative to pallidotomy?

A resurgence of interest in the surgical treatment of Parkinson's disease (PD) came with the rediscovery of posteroventral pallidotomy by Laitinen in 1985. Laitinen's procedure improved most symptoms in drug-resistant PD, which engendered wide interest in the neurosurgical community. Another lesioning procedure, ventrolateral thalamotomy, has become a powerful alternative to stimulate the nucleus ventralis intermedius, producing high long-term success rates and low morbidity rates. Pallidal stimulation has not met with the same success. According to the literature pallidotomy improves the "on" symptoms of PD, such as dyskinesias, as well as the "off" symptoms, such as rigidity, bradykinesia, and on-off fluctuations. Pallidal stimulation improves bradykinesia and rigidity to a minor extent; however, its strength seems to be in improving levodopa-induced dyskinesias. Stimulation often produces an improvement in the hyper- or dyskinetic upper limbs, but increases the "freezing" phenomenon in the lower limbs at the same time. Considering the small increase in the patient's independence, the high costs of bilateral implants, and the difficulty most patients experience in handling the devices, the question arises as to whether bilateral pallidal stimulation is a real alternative to pallidotomy.

Journal Article↗

Intraoperative diagnostic and interventional magnetic resonance imaging in neurosurgery.

OBJECTIVE: The benefits of intraoperative magnetic resonance (MR) imaging for diagnostic and therapeutic measures are as follows: 1) intraoperative update of data sets for navigational systems, 2) intraoperative resection control of brain tumors, and 3) frameless and frame-based on-line MR-guided interventions. The concept of an intraoperative MR scanner in the sterile environment of operating theater is presented, and its advantages, disadvantages, and limitations are discussed. METHODS: A 0.2-tesla magnet (Magnetom Open; Siemens AG, Erlangen, Germany) inside a radiofrequency cabin with a radiofrequency-shielded sliding door was installed adjacent to one of the operating theaters. A specially designed patient transport system carried the patient in a fixed position on an air cushion to the scanner and back to the surgeon. RESULTS: In a series of 27 patients, intraoperative resection control was performed in 13 cases, with intraoperative reregistration in 4 cases. Biopsies, cyst aspirations, and catheter placements (mainly frameless) were performed under direct MR visualization with fast image sequences. The MR-compatible equipment and the patient transport system are safe and reliable. CONCLUSION: Intraoperative MR imaging is a safe and successful tool for surgical resection control and is clearly superior to computed tomography. Intraoperative acquisition of data sets eliminates the problem of brain shift in conventional navigational systems. Finally, on-line MR-guided interventional procedures can be performed easily with this setting. As with all MR systems, individual testing with phantoms, application of correction programs, and determination of the optimal amount of contrast media are absolute prerequisites to guarantee patient safety and surgical success.

Adult↗

Is the medial globus pallidus a site for stimulation or lesioning in the treatment of Parkinson's disease?

After the encouraging report on bilateral pallidal stimulation by Siegfried in 1994, we started this procedure in 1995 and will report our experience in 6 patients with a mean follow-up of 1 year. In contrast to the good results of pallidotomy reported in the literature improving the 'on' symptoms as dyskinesias as well as 'off' symptoms such as rigidity, bradykinesia and on-off fluctuations, our results indicate that pallidal stimulation improves the 'off' symptoms only to a minor extent and L-dopa-induced dyskinesias remain the main indication. Considering the overall functional outcome, the question arises whether the medial globus pallidus should be lesioned or stimulated.

Aged↗

Image-guided neurosurgery with intraoperative MRI: update of frameless stereotaxy and radicality control.

Intraoperative shifts and resulting inaccuracies have been a concern in frame based and frameless stereotactically guided interventions, particularly in open microsurgical procedures. Trying to solve this problem, we developed a method to perform intraoperative MRI (0.2 tesla, Magnetom Open) and use intraoperatively acquired data sets to update neuronavigation. In 21 patients, intraoperative images could be used to reference navigation (mean accuracy of 0.83 +/- 0.31 mm). The operation was continued in 10 cases to resect detected tumor remnants using navigation, leaving 4 patients (19%) with residual tumor postoperatively. We showed that update of frameless stereotaxy to compensate for brain shift is feasible and might increase the number of cases where radiologically complete resection can be achieved.

Equipment Design↗

Pallidal stimulation: an alternative to pallidotomy?

A resurgence of interest in the surgical treatment of Parkinson's disease (PD) came with the rediscovery of posteroventral pallidotomy by Laitinen in 1985. Laitinen's procedure improved most symptoms in drug-resistant PD, which engendered wide interest in the neurosurgical community. Another lesioning procedure, ventrolateral thalamotomy, has become a powerful alternative to stimulate the nucleus ventralis intermedius, producing high long-term success rates and low morbidity rates. Pallidal stimulation has not met with the same success. According to the literature pallidotomy improves the "on" symptoms of PD, such as dyskinesias, as well as the "off" symptoms, such as rigidity, bradykinesia, and on-off fluctuations. Pallidal stimulation improves bradykinesia and rigidity to a minor extent; however, its strength seems to be in improving levodopa-induced dyskinesias. Stimulation often produces an improvement in the hyper- or dyskinetic upper limbs, but increases the "freezing" phenomenon in the lower limbs at the same time. Considering the small increase in the patient's independence, the high costs of bilateral implants, and the difficulty most patients experience in handling the devices, the question arises as to whether bilateral pallidal stimulation is a real alternative to pallidotomy.

Aged↗

Intraoperative magnetic resonance imaging to update interactive navigation in neurosurgery: method and preliminary experience.

We report on the first successful intraoperative update of interactive image guidance based on an intraoperatively acquired magnetic resonance imaging (MRI) date set. To date, intraoperative imaging methods such as ultrasound, computerized tomography (CT), or MRI have not been successfully used to update interactive navigation. We developed a method of imaging patients intraoperatively with the surgical field exposed in an MRI scanner (Magnetom Open; Siemens Corp., Erlangen, Germany). In 12 patients, intraoperatively acquired 3D data sets were used for successful recalibration of neuronavigation, accounting for any anatomical changes caused by surgical manipulations. The MKM Microscope (Zeiss Corp., Oberkochen, Germany) was used as navigational system. With implantable fiducial markers, an accuracy of 0.84 +/- 0.4 mm for intraoperative reregistration was achieved. Residual tumor detected on MRI was consequently resected using navigation with the intraoperative data. No adverse effects were observed from intraoperative imaging or the use of navigation with intraoperative images, demonstrating the feasibility of recalibrating navigation with intraoperative MRI.

Adult↗

Intraoperative computer-assisted neuronavigation in functional neurosurgery.

The clinical experience with a frameless computer-assisted neuronavigational system (ISG. Canada) used in functional neurosurgery is described. The advantage of image-guided surgery is stressed for functional procedures of the cortex with delineation of the gyral pattern, e.g. motor cortex stimulation and procedures at the base of the skull with triplanar and three-dimensional reconstruction of the bony landmarks. A general use of the device for aiming at subcortical targets cannot be recommended. Limitations are the accuracy (< or = 2.2 mm) and software deficiencies and the lack of a reliable fixation of the position sensing arm (wand).

Cerebral Cortex↗