PubMed Health⌕ Search

Biomedical subjects

V Marra

Publications and source records attributed to V Marra.

8 recordsLinked to original sources

The Italian multi-centre project on evaluation of MRI and other imaging modalities in early detection of breast cancer in subjects at high genetic risk.

This report presents the preliminary results of the first phase (21 months) of a multi-centre, non-randomised, prospective study, aimed at evaluating the effectiveness of contrast-enhanced magnetic resonance imaging (MRI), X-ray mammography (XM) and ultrasound (US) in early diagnosis of breast cancer (BC) in subjects at high genetic risk. This Italian national trial (coordinated by the Istituto Superiore di Sanità, Rome) so far recruited 105 women (mean age 46.0 years; median age 51.0; age range 25-77 years), who were either proven BRCA1 or BRCA2 mutation carriers or had a 1 in 2 probability of being carriers (40/105 with a previous personal history of BC). Eight cases of breast carcinomas were detected in the trial (mean age 55.3 years, median age 52.5; age range 35-70 years; five with previous personal history of BC). All trial-detected BC cases (8/8) were identified by MRI, while XM and US correctly classified only one. MRI had one false positive case, XM and US none. Seven "MRI-only" detected cancers (4 invasive, 3 in situ) occurred in both pre- (n = 2) and post-menopausal (n = 5) women. With respect to the current XM screening programmes addressed to women in the age range 50-69 years, the global incidence of BC in the trial (7.6%) was over ten-fold higher. The cost per "MRI-only" detected cancer in this particular category of subjects at high genetic risk was substantially lower than that of an XM-detected cancer in the general women population. These preliminary results confirmed that MRI is a very useful tool to screen subjects at high genetic risk for breast carcinoma, not only in pre-, but also in post-menopausal age, with a low probability of false positive cases.

Adult↗

[Positive predictive value of radiologic features in mammography and contribution of assessment procedures].

PURPOSE: To investigate the positive predictive value for cancer of abnormal mammographic findings and the role of assessment procedures. MATERIALS AND METHODS: We reviewed a series of 962 patients recalled and examined in the 1st Breast Screening Center of Turin, out of 18; 996 women aged 50-59 screened for the first time from 1991 to 1995, within a population-based mammography program. The diagnostic assessment procedures included one or more of the following: physical examination, additional mammographic views (detail or magnification), ultrasonography, and ultrasonography/X-ray-guided fine needle aspiration cytology. Surgical biopsies detected 152 cancers. RESULTS: The positive predictive value for screening mammography with abnormal findings steadily grew from 10.9% in 1991-92 to 15.6% in 1993, topping 21.1% in 1994 and 20.1% in 1995. The highest positive predictive value for cancers was observed among cases referred for opacities with irregular margins (88.2%) and isolated calcifications (23.8%). The benign/malignant biopsy ratio was .54 in 1991-92, .31 in 1993, .27 in 1994 and .25 in 1995. The accuracy of assessment procedures was different for each abnormal radiologic sign: the accuracy of cytology was high for opacities, intermediate for calcifications, low for architectural distortions; ultrasonography and physical examination had low sensitivity among cases referred for calcifications or opacities with regular margins. The positive predictive value of surgical indications was high for opacities, intermediate for calcifications, low for architectural distortions. The role of assessment procedures in excluding surgery was different for each abnormal radiologic sign. DISCUSSION AND CONCLUSIONS: The results of this study confirm the accuracy of mammography in the early detection of breast cancer and the different role of assessment procedures in the various abnormal mammographic findings. The improvement in positive predictive value for screening recalls from about 10% (close to recommended European standards) up to about 20% (well above European standards) demonstrates the importance of the "learning curve" within the screening team. Most of this improvement could be referred to refined diagnostic criteria for calcifications, as shown by an increase in positive predictive value for calcifications from 13.7% in 1991-92 to 40.5% in 1995.

Breast Neoplasms↗

[Neurolytic block of the celiac plexus and splanchnic nerves with computed tomography. The experience in 150 cases and an optimization of the technic].

INTRODUCTION: CT-guided celiac plexus and splanchnic nerve neurolytic blocks are procedures for pain relief in patients with upper abdominal malignancies. In the last 20 years, the technique has been modified by the introduction of CT guidance providing improved precision and safety. We report our personal experience and provide suggestions for technique optimization. MATERIALS AND METHODS: In 1991-1998 we performed 150 celiac plexus and/or splanchnic nerve neurolytic blocks with ethyl alcohol in 144 cancer patients; the procedure was repeated in 6 patients. In 69% of cases the patient had a pancreatic lesion. We prefer an anterior approach with very thin needles (22 Gauge). The sites of alcohol injection (celiac plexus, splanchnic nerves or both) are chosen after evaluation of anatomy by preliminary CT scans, or during the procedure, depending on alcohol (mixed with a contrast agent) spread. RESULTS: The mean duration of the procedure ranged 50 min (1991) to 22 min (1998). 48 hours after the block we obtained major pain relief in 79% of cases. After 15 days, 21% of patients had no pain (drugs: none), 29% had mild pain (therapy: non-steroid anti-inflammatory drugs), 32% had marked pain (therapy: non-steroid anti-inflammatory drugs and, occasionally, opioids), 18% had severe pain (only opioid therapy). Pain relief was more frequent in splanchnic nerve blocks. DISCUSSION: Our experience confirms that neurolytic celiac plexus and/or splanchnic nerve block is a good choice in the treatment of upper abdominal cancer pain. We would also like to add that: 1) celiac plexus block with CT guidance (with the needle tip positioned anterior to aorta) and splanchnic nerve block (with the needle tip positioned posterior to diaphragmatic crura) are no longer two separated techniques, but they can be chosen and combined according to patients needs. 2) All procedures can be performed with anterior approach, in supine position, with a single thin needle, allowing to reach the target without any complication, even after puncturing stomach, liver, bowel, pancreas or aorta. 3) With CT guidance, even splanchnic nerve neurolysis is a low-risk technique, which should be adopted in all cases of insufficient alcohol spread in the celiac plexus. 4) When the operators are skilled and experienced enough, the time required for the block can be significantly decreased to nearly the time required for US-guided or fluoroscopic-guided procedures.

Autonomic Nerve Block↗

[Breast carcinoma diagnosed in mammographic screening incidentally. Research on the radiologic signs in prior mammograms].

PURPOSE: To determine how many cancers screen-detected at subsequent rounds were already visible on previous screening mammograms, and to study their radiological features. MATERIALS AND METHODS: The previous screening mammograms of 100 women who had cancers screen-detected at subsequent rounds (group A), and the negative screening mammograms of 200 women (group B) who had a further negative screening test two years later, were mixed for a new reading. The two groups were similar for age and year of examination. These films were blindly reviewed by 5 radiologists. Then, mammograms were reviewed retrospectively, with knowledge of subsequent diagnostic results. Finally the A group findings were classified as: 1) true negative: no radiological signs; 2) minimal sign: a nonspecific abnormality is retrospectively visible at the site of subsequent cancer; 3) false negative: "she should have been recalled"; 4) misdiagnosis at assessment: the woman had been recalled, but the cancer was missed after the assessment procedures. RESULTS: 60% of cases were true negatives, 29% were minimal signs, 9% were false negative and 2% were misdiagnosed at assessment. The most common radiological sign found among false negative cases was an architectural distortion: opacities and calcifications were more frequent among minimal signs. Only 10 of 40 cancers retrospectively visible on previous mammograms had reached stage II at diagnosis. At blinded review, the radiologists found false abnormalities in a considerable number of healthy women (average: 29%). DISCUSSION AND CONCLUSIONS: Our study shows that mammography sensitivity can be improved. Cancer radiological signs may go undetected due to difficult interpretation (opacities, calcifications) or perception (architectural distortions). The use of a low threshold of suspicion (as in a reading test) in real screening might permit to detect more cancers (most of them, however, would not reach advanced stages at subsequent rounds), but might also lead to many unnecessary assessments and, probably, to some benign biopsies in healthy women. In conclusion, an attempt at improving mammography sensitivity by lowering the threshold of suspicion can not be directly recommended due to the considerable negative effects related to a loss in specificity. A reading test similar to the one presented in our study would be a useful training procedure for radiologists who are involved in a screening program.

Breast Neoplasms↗

[Quality and homogeneity monitoring of radiologists in the Turin mammographic screening. Comparison of the pilot phase results].

The Turin mammographic screening program was designed to be carried out in several independent screening centers because of the large proportion of population involved (76,000 women aged 50 to 59 years). The first center began working in 1992 and the second center was opened in 1995. The latter center carried out an early pilot study in which 1024 women were examined to assess the homogeneity and the quality of the results. The results were then compared with European quality standards and with the results of both the pilot and the active screening periods in the first center. The results from the second center were very good as far as detection rate is concerned (7.8/1000-2.9/1000 in carcinoma < or = 1 cm). This rate is higher than the so-called "desirable" European standard. Recall rate and benign/malignant biopsy ratio were higher than the so-called "fair" European standard (recall rate: 7.1%; B/M biopsy ratio: 0.62). These results are slightly superior to those of the pilot period in the first center and slightly inferior to the results of active screening in the same center. The improvement relative to the pilot period in the first center (1991) is probably related to technical progress, such as the introduction of the double mammographic projection. The difference relative to the results from the active screening period in the first center (1992-1994) reflects different specific experience. Even though pilot periods have no statistical significance, they can be used for comparison, and in our experience they have proved, with positive results, the quality of the mammographic screening program provided to the Turin population.

Female↗

[Dosimetric and qualitative evaluations of the use of rhodium filtration in mammography].

The value of rhodium filtration in mammography was compared with that of conventional molybdenum; dosimetric and qualitative tests were performed on a phantom and in vivo on informed and consenting patients. Phantom dosimetric tests confirmed a dose reduction with rhodium filtration changing according to thickness and primary beam energy. With rhodium filtration the dose decreased by 40% on the average topping 67% in breasts thicker than 6.5 cm. No significant differences were observed between rhodium and molybdenum filtration in clinical and phantom qualitative tests. Four radiologists--three of them in double blind--studied 29 mammograms repeated in the same technical setting and expressed a very slight preference for molybdenum also in thick and dense breasts. The slight preference was not based on higher diagnostic yield and therefore clinically irrelevant. Preferences appeared to be subjective, differing from one radiologist to another. In conclusion, the authors suggest the use of rhodium filtration in thick breasts because of the lower administered dose and of shorter exposure time with direct magnification.

Breast Neoplasms↗

[Role of ultrasonic diagnosis as a complementary method in contrast radiography of the intestines].

This study was aimed at evaluating US reliability and sensitivity in identifying inflammatory or neoplastic bowel diseases in symptomatic patients. Two hundred and fifty patients who had been referred to our Unit for double-contrast barium enema of small bowel and colon, underwent panoramic and targeted abdominal US. According to well-known pathological criteria--i.e., intestinal wall thicker than 5 mm, and pseudo-kidney pattern--US had 61.7% sensitivity for inflammatory and neoplastic bowel diseases. The results indicate that US findings negative for intestinal disease are not reliable unless confirmed by contrastographic and endoscopic examinations. However, panoramic US occasionally demonstrated intestinal abnormalities and allowed collateral diseases to be observed in other organs or apparatuses. These abnormalities had been missed at contrastography, and were sometimes responsible for the symptoms the patients complained of. Targeted US emerged as a useful tool for detailing the lesions demonstrated by double-contrast barium enema, especially in case of expansive pathologies (size of the mass and relationship to adjacent organs).

False Negative Reactions↗

[Hematologic diagnosis using fluorescence].

The authors have used a fluorescent supravital staining technique that allow the simultaneous study of platelets, the fibrin meshwork, the morphology of white blood cells and its phagocytic activity, the presence of immature cells. The technique is simple and fast and owing to all the information that it furnish, the authors designated it with the initials FED.

Acridine Orange↗