Twelve-month outcome after coronary stent implantation without predilatation.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to V Martí.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
OBJECTIVES: The mechanisms of cardiac allograft vasculopathy and its predisposing factors are multifactorial and as yet not well established. To determine the influence of endothelial dysfunction on the development of intimal thickening, we prospectively analyzed the vasomotor response to acetylcholine and nitroglycerin, as well as other donor and recipient variables. Findings were correlated with the coronary intimal thickness, which was evaluated by means of intravascular ultrasonography. METHODS: Nineteen patients who had undergone heart transplantation 4.89 +/- 2.35 years previously and who had angiographically normal coronary arteries were included. Endothelial function was analyzed by quantitative coronary analysis of the vasomotor response of the left anterior descending artery to acetylcholine. An intimal thickness index, reflecting the percentage of intima obstructing the coronary lumen, was calculated. RESULTS: Nine (47%) patients showed endothelial dysfunction, and the remaining 10 (53%) patients had a normal response. Four (44%) of 9 patients with a weight gain of greater than 20% after the operation showed endothelial dysfunction compared with none of the 10 patients with normal responses (P <.04). The severity of the intimal thickness correlated with the years after transplant (r = 0.45, P <.05). Patients with endothelial dysfunction had more intimal thickening than those without (32% +/- 17% vs 17% +/- 12%, respectively; P <.05). Furthermore, the degree of intimal thickening correlated with the magnitude of the vasomotor response to acetylcholine (r = -0.60, P =.006). No relationship was found between intimal thickness and the vasodilatory response to nitroglycerin. As independent variables for intimal thickness, multivariate analysis detected the magnitude of the response to acetylcholine (P =.0005), years after transplant (P =.01), and ischemic time (P =.03). CONCLUSIONS: Cardiac allograft vasculopathy is a multifactorial disease the severity of which increases over time. Endothelial dysfunction is a predictive factor of intimal thickening severity. Predisposing factors that provoke endothelial injury, such as perioperative ischemic time and obesity, may contribute to the development of allograft vasculopathy.
Explore the source record for details and available documents.
INTRODUCTION: There is scant information about the effects of thrombolysis in the evolution of right bundle-branch block (RBBB) in the setting of acute anterior myocardial infarction. The aim of this study has been to analyse these effects and its impact on prognosis. METHODS: We studied 54 patients who presented a RBBB related to an acute anterior myocardial infarction. We defined two groups: those who received thrombolytic treatment and those who did not. We analysed the evolution of RBBB (transience, moment of onset, moment of disappearance) and its relationship with in-hospital mortality.Twenty-one patients (39%) received thrombolytic treatment (groupT) and 33 patients (61%) (group NT) did not. RESULTS: The incidence of late appearance (> 6 h) of RBBB was less frequent in group T compared with group NT (10% vs. 33%, p = 0.04). The incidence of transient block was similar in the two groups (57% vs. 45%, p ns). However, early disappearance of RBBB (in < 6 hours) was more common in group T than in group NT (33% vs. 9%, p = 0.04). Mortality was higher in patients with RBBB present at 24 h after admission) than in those with RBBB resolved in less than 24 hours (in group NT, 55% vs. 8%, p = 0.02 and in group T 50% vs. 0%, p = 0.02, respectively). CONCLUSIONS: Thrombolysis seems to influence the moment of onset and disappearance of RBBB by promoting its early disappearance and avoiding its late appearance. Disappearance of RBBB is associated with a better prognosis.
We report a 43 years old female, admitted due to fatigability, asthenia and diffuse abdominal pain. On admission, obesity, slowness of thinking, bradycardia, distention of jugular veins and ascites were observed on physical examination. Laboratory showed undetectable thyroid hormone levels, a chest X ray showed bilateral pleural effusion and an enlarged heart. An echocardiography showed a massive pericardial effusion with collapse of the right atrium and dilatation of both caval veins. A pericardial tap was performed, draining 350 ml. Thyroid hormone substitution was started and after 12 months of follow up, the heart size decreased and a control echocardiogram showed a minimal pericardial effusion.
The cutting balloon is a new device for coronary angioplasty, which, by the combination of incision and dilatation of the plaque, is believed to minimize arterial wall trauma, the neoproliferative response, and subsequent restenosis. In this study, we sought to determine predictors of the restenosis using this technique. Seventy-seven patients underwent successful coronary angioplasty with cutting balloon alone. In 67 of these patients (87%), we performed a control angiogram at 6-month follow-up. Pre-, post-, and late angiographic results were evaluated by quantitative coronary analysis. Clinical and angiographic variables were correlated with restenosis as a binary variable and a continuous variable (late loss and late minimum luminal diameter). Univariate analysis showed that the immediate postprocedure minimum luminal diameter (MLD) was smaller in the restenotic group (defined as MLD > 50% by quantitative coronary angiography) than in the nonrestenotic group (1.90 +/- 0.47 mm vs. 2.19 +/- 0.56 mm, P < 0.05). In addition, the immediate percentage of stenosis was higher in the restenotic group than in the nonrestenotic group (37% +/- 10% vs. 27% +/- 11%, P < 0. 003). Multivariate analysis identified the immediate postcutting balloon percentage of stenosis as an independent determinant of binary restenosis (P < 0.008). When restenosis was defined as a continuous variable, the immediate postprocedure MLD was an independent predictor of late loss (P < 0.02) and of late MLD (P < 0. 0002). No clinical, preprocedure angiographic, or technical variables tested were associated with restenosis. The degree of postprocedural residual stenosis after cutting balloon angioplasty is predictive of late restenosis.
A female with mitral valvular disease presented an acute myocardial infarction. She suddenly complained of recurrent chest pain with symptoms of pulmonary edema. The angiogram evidenced multiple coronary thromboemboli. A combined strategy using intracoronary thrombolysis, a platelet glycoprotein IIb/IIIa antagonist (abciximab) and percutaneous transluminal coronary angioplasty to help disrupt the thrombus was performed. Clinical and angiographic signs of coronary reperfusion were rapidly achieved. No bleeding complications appeared.
Explore the source record for details and available documents.
The development of capillary zone electrophoresis (CZE) methods for the determination of metal cyanide complexes in real samples showed some problems, such as the low detection signal of Au (CN)2- and the low resolution between Ni(II) and Fe(II) cyanides in gold processing solutions, and the lack of separation of Pt(CN)4(2-) and Pd(CN)4(2-) in the leachates from automobile catalytic converters. To optimize some analytical parameters, the present study thus focused on the application of experimental designs and multiregression models. The following factors were examined by a two-level factorial design: applied voltage, injection time, detection wavelength, buffer ion, ionic strength and buffer modifiers. For optimization of the CZE method, subsequent response-surface experiments with the important factors were made with the two kinds of leaching solutions. Optimal analytical conditions were obtained in each case, giving good detection signals and resolution for the components of the studied leachates.
A patient with an angiographically unrecognized minor coronary dissection in a stent-covered coronary segment in which a type D spiral dissection extended submedially to the distal artery is described. This complication occurred 6 months after stent implantation and was ascribed to injury of the stented vessel wall during an intravascular ultrasound study.
We studied 2 groups of patients with (n = 14) and without (n = 42) minor coronary dissections following cutting balloon angioplasty. Patients with a minor dissection had a longer length of lesion, higher percentage of stenosis, and greater acute gain after angioplasty; at 6-month follow-up both groups had a similar net gain and restenosis rate, suggesting that minor dissection after cutting balloon angioplasty has no influence on restenosis.
Explore the source record for details and available documents.
A 2-year-old patient with severe mitral regurgitation associated with a mass originating from the anterior leaflet of the mitral valve is reported. Excision of the tumor and mitral valve repair was performed. Four years later the child remains asymptomatic with no recurrence of the tumor or regurgitation.
Explore the source record for details and available documents.
INTRODUCTION AND OBJECTIVES: The Multi-Link intracoronary stent is a balloon-expandable stainless steel stent with an interconnected ring structure designed to provide a high degree of compressive resistance while preserving longitudinal flexibility. We present the results of our initial experience with the implantation of this stent. PATIENTS AND METHODS: From May 1996 to April 1997, 124 Multi-link stents were implanted in 97 patients. Mean age 62.2 +/- 11 years. All patients included had a coronary artery diameter > 2.7 mm. Clinical presentation includes stable angina in 20, unstable angina in 72, and myocardial infarction in 5 patients. According to the ACC/AHA classification 6 lesions were type A, 72 type B and 19 type C. The implantation of the stent was for "de novo" lesions in 85 patients and for restenosis in 12. Patients were treated after the procedure with a combination of aspirin and ticlopidine, except six of them who received aspirin and acenocumarol. 16 patients were treated additionally with Abciximab. The degree of stenosis was determined by quantitative angiography. RESULTS: The delivery of the stent was successful in all patients. The degree of stenosis before the procedure was 79.6 +/- 13.1%, and after the stent deployment was 17.7 +/- 11.4%. Three patients presented a non-Q-wave myocardial infarction, two patients had a subacute stent thrombosis, one of them died due to heart failure. During a follow-up of 4.7 +/- 2.6 months five patients were readmitted with recurrent angina (4 due to restenosis and one for vessel occlusion) and one patient with heart failure after myocardial infarction died suddenly three weeks after the dilatation. CONCLUSIONS: The Multi-Link stent was implanted successfully in all patients with a low incidence of complications, showing at the follow-up a reduced rate of clinical restenosis.
OBJECTIVES: The present study was undertaken to prospectively and comparatively evaluate the role of serial myocardial perfusion imaging and coronary angiography for the detection of early vasculopathy in a large patient population and also to determine the short- and long-term efficacy of augmented immunosuppressive therapy in the potential reversal of the early vasculopathy. BACKGROUND: Allograft vasculopathy is the commonest cause of death after the first year of heart transplantation. Anecdotal studies have reported the efficacy of augmented immunosuppressive therapy after early detection of vascular involvement. However, no prospective study has evaluated the feasibility of early detection and treatment of allograft vasculopathy. METHODS: In 76 cardiac allograft recipients, 230 coronary angiographic and 376 scintigraphic studies were performed in a follow-up period of 8 years. Angiography was performed at 1 month and every year after transplantation, and thallium-201 scintigraphy at 1, 3, 6 and 12 months after transplantation and twice a year thereafter. Prospective follow-up of 76 patients showed that 18 developed either angiographic or scintigraphic evidence of coronary vasculopathy. All episodes were treated with 3-day methylprednisolone pulse and antithymocyte globulin. RESULTS: Twenty-two episodes of vasculopathy were diagnosed and treated in these 18 patients. Of these 22 episodes, two were detected only by angiography, seven by both angiography and scintigraphy, four by scintigraphy and histologic evidence of vasculitis and nine episodes only by thallium-201 scintigraphy studies. Angiographic and/or scintigraphic resolution was observed in 15 of the 22 episodes (68%) with augmented immunosuppression. The likelihood of regression was higher when treatment was instituted within the first year of transplantation (92%) than after the first year (40%) (p = 0.033). Eighty percent of patients who responded to follow-up. CONCLUSIONS: The present study suggests that early detection of allograft coronary vasculopathy is feasible with surveillance myocardial perfusion or coronary angiographic studies. When identified early after transplantation, immunosuppressive treatment may result in regression of coronary disease.
Myocardial bridging of the epicardic coronary arteries is not an uncommon finding in angiographic or necropsic studies. Patients who have symptoms usually improve with medical treatment. However, in refractory patients a surgical myotomy of overlying myocardium and/or a coronary bypass may be needed. We report two patients with long myocardial bridges in the mid-left anterior descending coronary artery, who had recurrent angina refractory to conventional treatment. In both patients two consecutive coronary stents were successfully implanted. At five and six months follow-up they are asymptomatic and with good exercise tolerance.