PubMed Health⌕ Search

Biomedical subjects

V Mlynárik

Publications and source records attributed to V Mlynárik.

At least 19 recordsLinked to original sources

Cerebral glutamate metabolism during hypoglycaemia in healthy and type 1 diabetic humans.

BACKGROUND: The mechanisms responsible for the progressive failure of hypoglycaemia counterregulation in long-standing type 1 diabetes are poorly understood. Increased brain glucose uptake during hypoglycaemia or alterations of brain energy metabolism could effect glucose sensing by the brain and thus contribute to hypoglycaemia-associated autonomic failure. MATERIALS AND METHODS: Type 1 diabetic patients (T1DM) and healthy volunteers (CON) were studied before, during and after a hypoglycaemic (50 mg dL(-1)) hyperinsulinaemic (1.5 mU kg(-1) min(-1)) clamp test. The (1)H magnetic resonance spectroscopy of the occipital lobe of the brain was performed employing the STEAM localization technique. The water signal was suppressed by the modified SWAMP method. All spectra were acquired on a 3 Tesla scanner (80 cm MEDSPEC-DBX, Bruker Medical, Ettlingen, Germany) using a 10-cm diameter surface coil. RESULTS: During hypoglycaemia, T1DM showed blunted endocrine counterregulation. At baseline the brain tissue glucose : creatine ratio was lower in CON than in T1DM (CON 0.13 +/- 0.05 vs. T1DM 0.19 0.11; P < 0.01). During hypoglycaemia glucose : creatine ratios decreased in both groups (CON 0.07 +/- 0.08, P < 0.05; T1DM 0.03 +/- 0.03, P < 0.001). A significant drop in the glutamate : creatine ratio could only be found in CON during hypoglycaemia (CON 1.36 +/- 0.08 vs. 1.26 +/- 0.11; P < 0.01; T1DM 1.32 +/- 0.13 vs. 1.28 +/- 0.15; P = NS). The ratios of glutamine, N-acetylaspartate, choline and myo-inositol : creatine were not different between both groups and did not change throughout the experiment. CONCLUSIONS: Only in CON does moderate hypoglycaemia reduce intracerebral glutamate concentrations, possibly owing to a slower substrate flux through the tricarboxylic acid cycle in neurones. The maintenance of normal energy metabolism in T1DM during hypoglycaemia might effect glucose sensing in the brain and contribute to hypoglycaemia-associated autonomic failure.

Adult↗

In vitro study of astrocytic tumour metabolism by proton magnetic resonance spectroscopy.

In vivo magnetic resonance spectroscopy (MRS) studies of glial brain tumours reported that higher grade of astrocytoma is associated with increased level of choline-containing compounds (Cho) and decreased levels of N-acetylaspartate (NAA) and creatine and phosphocreatine (Cr). In this work, we studied the metabolism of glioma tumours by in vitro proton magnetic resonance spectroscopy (1H-MRS). 1H-MR spectra were recorded in vitro from perchloric acid extracts of astrocytoma (WHO II) and glioblastoma multiforme (WHO IV) samples. We observed differences between astrocytoma and glioblastoma multiforme in the levels of Cho, alanine, lactate, NAA, and glutamate/glutamine. In astrocytoma samples, we found higher MR signal of NAA and lower signal of Cho and alanine. MR spectra of glioblastoma samples reported significantly higher levels of lactate and glutamate/glutamine. In contrast, levels of Cr were the same in both tumour types. We also determined NAA/Cr and Cho/Cr ratios in the tumour samples. The NAA/Cr ratio was higher in astrocytomas than in glioblastomas multiforme. Conversely, the Cho/Cr ratio was higher in glioblastoma multiforme. The results indicate that MRS is a promising method for distinguishing pathologies in human brain and for pre-surgical grading of brain tumours.

Aspartic Acid↗

1H NMR relaxation times of skeletal muscle metabolites at 3 T.

This study reports proton relaxation times of water and metabolites in soleus and tibialis anterior muscles of young healthy volunteers at 3 T. The results are in agreement with data reported for 1.5 and 4 T, showing a steady increase of spin-lattice relaxation times of water, creatine and lipids with B(0) and no effect of B(0) on spin-spin relaxation. Comparison between muscles revealed a longer spin-spin relaxation time of water in soleus than in tibialis anterior muscle (31+/-1 ms vs. 28+/-1 ms, p<0.05). These data can be applied to relaxation correction for the absolute quantification of skeletal muscle metabolite concentrations and further sequence optimization.

Adult↗

Transverse relaxation mechanisms in articular cartilage.

Relaxation rates in the rotating frame (R1rho) and spin-spin relaxation rates (R2) were measured in articular cartilage at various orientations of cartilage layer to the static magnetic field (B0), at various spin locking field strengths and at two different static magnetic field strengths. It was found that R1rho in the deep radial zone depended on the orientation of specimens in the magnet and decreased with increasing the spin locking field strength. In contrast, R1rho values in the transitional zone were nearly independent of the specimen orientation and the spin locking field strength. Measurements of the same specimens at 2.95 and 7.05 T showed an increase of R1rho and most R2 values with increasing B0. The inverse B0 dependence of some R2 values was probably due to a multicomponent character of the transverse magnetization decay. The experiments revealed that the dominant T1rho and T2 relaxation mechanism at B0 < or = 3 T is a dipolar interaction due to slow anisotropic motion of water molecules in the collagen matrix. On average, the contribution of scalar relaxation due to rapid proton exchange in femoral head cartilage at 2.95 T is about 6% or less of the total R1rho at the spin locking field of 1000 Hz.

Cartilage, Articular↗

Proteoglycan depletion and magnetic resonance parameters of articular cartilage.

Calcium ions and various amounts of proteoglycans were removed from porcine articular cartilage explants using ethylenediaminetetraacetic acid or guanidinium chloride solutions. The water proton magnetic parameters such as T(1) and T(2) relaxation times, diffusion (D), and magnetization transfer (M(S)/M(0)) were then measured by 1D MR microscopy on native specimens, after incubation in the extracting solutions and after final reconditioning in a physiological saline. While the replacement of the interstitial fluid by the treating solutions strongly affected the various MR parameters, calcium depletion did not show any influence on the MRI appearance of the chondral tissue. Interestingly, only the longitudinal relaxation time T(1) and the diffusion coefficient D were seen to be sensitive to an extensive proteoglycan depletion of the tissue. Our results indicate that a modest proteoglycan depletion, as it occurs in the early stage of a pathological cartilage degradation, has little relevance to the above MR parameters. Further MRI studies on the macromolecular components of cartilage are, therefore, necessary for a better understanding of the interaction mechanisms between water and extracellular matrix that might lead to the early diagnosis of the cartilage damage.

Animals↗

Proton T (1) and T (2) relaxation times of human brain metabolites at 3 Tesla.

Longitudinal and transverse relaxation times were measured for proton MRS signals from human brain metabolites at 3 T using a short-echo STEAM protocol and a surface coil as a transmitter/receiver. Volumes of interest containing mostly grey or mostly white matter were selected in occipital lobes of healthy subjects and relaxation times for the following resonances were obtained: N-acetylaspartate at 2.01 ppm (T(1) and T(2)), glutamate at 2.35 ppm (T(1)), creatine at 3.03 and 3.92 ppm (T(1) and T(2)), choline-containing substances at 3.22 ppm (T(1) and T(2)), myo-inositol at 3.57 and 3.65 ppm (T(1)) and the overlapping signals of glutamate and glutamine at 3.75 ppm (T(1)). The T(1) relaxation times obtained range from 0.97 to 1.47 s for grey matter and from 0.87 to 1.35 s for white matter. On the other hand, T(2) relaxation times range from 116 to 247 ms and from 141 to 295 ms in grey and white matter, respectively. Generally, the T(1) values measured at 3 T are close to the previously published data found at 1.5, 2 and 4.1 T. Also, the T(2) values confirm the previously observed decrease in transverse relaxation times with increasing static magnetic field. The proton relaxation times obtained will allow improved sequence design and spectra quantitation at 3 T, currently tested for enhanced clinical applications.

Adult↗

Low-power water suppression by hyperbolic secant pulses with controlled offsets and delays (WASHCODE).

A class of chemical-shift-selective (CHESS) water suppression (WS) schemes is presented in which the characteristic frequency-domain excitation profiles of "adiabatic" full-passage (AFP) RF pulses are utilized for frequency-selective excitation of the water resonance. In the proposed WS schemes, dubbed WASHCODE, hyperbolic secant (HS) pulses were used as the AFP pulses. Besides the high immunity of WS efficiency toward B(1) inhomogeneity, these sequences also exhibit extraordinary insensitivity to the dispersion of the water T(1) relaxation times. The actual performance of the proposed WS schemes was achieved in particular by optimizing the frequency offsets of WS HS pulses and the time intervals between them. To reduce the RF power requirements of these WS sequences for in vivo applications, HS pulses with the minimum possible frequency bandwidths were employed, which also substantially reduced the adverse effects on the observed proton MR spectra. The proposed WS schemes were evaluated by simulations based on the Bloch equations. Several WS sequences which looked particularly promising were verified experimentally on the human brain on a 3 T MR scanner using very short echo-time STEAM for volume selection and a standard single-loop surface coil for both signal transmission and reception. Routinely, water-suppression factors ranging from 2000 to 4000 were achieved in vivo without additional adjustment of parameters for individual subjects and without violating legal safety limits.

Brain↗

Bilaminar pattern of tibial condyle cartilage layer on the fat-suppressed 3D gradient echo images: artifact or structural and biochemical difference in composition of cartilage?

The purpose of this study was to examine if an unusual bilaminar pattern of lateral tibial condyle cartilage layer on the fat-suppressed three-dimensional (3D) spoiled gradient echo sequence is artifactual or correlates with structural and/or biochemical composition of cartilage. The laminar appearance of the lateral tibial condyle cartilage layer was studied on fat-suppressed 3D spoiled gradient echo MR images of the knee joint in 67 patients (mean age: 28y) performed at 1.0 Tesla. After i.v. administration of gadopentetate dimeglumine, diffusion of the contrast media into cartilage layer was qualitatively analysed over time on inversion recovery spin echo images of knee joints of five asymptomatic volunteers (mean age: 25y). In a patient with osteosarcoma and total knee replacement, MR examination of cartilage layer of lateral tibial plateau was compared with histologic specimens stained with Safranin-O, demonstrating proteoglycan distribution in cartilage. The retrospective analysis of 67 knee joints revealed a bilaminar appearance of lateral tibial condyle cartilage layer in the gradient echo images in the majority of cases (81%) with a statistically significant tendency to a trilaminar pattern in patients older than 20 years. With i.v. contrast administration, the contrast enhancement was only observed in the superficial zone of tibial cartilage layer. Histologic specimens in one patient demonstrated a good correlation between thickness of proteoglycan-free and proteoglycan-rich laminae of lateral tibial condyle on Safranin-O staining with hyperintense and hypointense zones, respectively, on corresponding fat-suppressed 3D spoiled gradient echo images (correlation coefficient of 0.87). Bilaminar pattern of tibial condyle cartilage layer on fat-suppressed 3D spoiled gradient echo images in younger subjects is not an artifact or an intrachondral lesion, but it may represent a regional difference in composition of extracellular cartilage matrix possibly produced by a highly-oriented collagen fiber structure associated with a high concentration of proteoglycans in the middle and deep portion of the cartilage layer.

Adolescent↗

Multivoxel 3D proton spectroscopy in the brain at 1.5 versus 3.0 T: signal-to-noise ratio and resolution comparison.

BACKGROUND AND PURPOSE: The new 3.0-T imagers theoretically yield double the signal-to-noise ratio (SNR) and spectral resolution of 1.5-T instruments. To assess the possible improvements for multivoxel 3D proton MR spectroscopy (1H-MRS) in the human brain, we compared the SNR and spectral resolution performance with both field strengths. METHODS: Three-dimensional 1H-MRS was performed in four 21-29-year-old subjects at 1.5 and 3.0 T. In each, a volume of interest of 9 x 9 x 3 cm was obtained within a field of view of 16 x 16 x 3 cm that was partitioned into four (0.75-cm-thick) 16 x 16-voxel sections, yielding 324 (0.75-cm3) signal voxels per examination. RESULTS: In an acquisition protocol of approximately 27 min, average voxel SNRs increased 23-46% at 3.0 versus 1.5 T in the same brain regions of the same subjects. SNRs for N-acetylaspartate, creatine, and choline, respectively, were as follows: 15.3 +/- 4, 8.2 +/- 2.2, and 8.0 +/- 2.0 at 1.5 T and 22.4 +/- 7.0, 10.1 +/- 3.5, and 10.1 +/- 3.6 at 3.0 T. Spectral resolution (metabolite linewidths) were 3.5 +/- 0.5 Hz at 1.5 T versus 6.1 +/- 1.5 Hz at 3.0 T in approximately 900 voxels. Spectral baselines were noticeably flatter at 3.0 T. CONCLUSION: Expected gains in SNR and spectral resolution were not fully realized in a realistic experiment because of intrinsic and controllable factors. However, the 23-46% improvements obtained enable more reliable peak-area estimation and an 1H-MRS acquisition approximately 50% shorter at 3.0 versus 1.5 T.

Adult↗

A study of creatine kinase reaction in rat brain under chronic pathological conditions-chronic ischemia and ethanol intoxication.

Creatine kinase reaction rates were measured by the magnetisation transfer technique in brains of healthy adult and aged rats and in rats with chronic cerebral ischemia and chronic ethanol intoxication. These measurements indicated that the rate constant of the creatine kinase reaction is significantly reduced in the case of severe chronic cerebral ischemia in aged rats. In the adult rats, during chronic ethanol intoxication after 3 weeks of administration of 3 ml of 30% ethanol once a day via a gastric tube, a significant decrease in the pseudo first-order rate constant k(for) of the creatine kinase reaction was also found. In contrast, mild chronic cerebral ischemia in adult rats produced an increase in the reaction rate 4 weeks after occlusion. At the same time, corresponding conventional phosphorus magnetic resonance spectra showed negligible changes in signal intensities.

Adenosine Triphosphate↗

Very short echo time proton MR spectroscopy of human brain with a standard transmit/receive surface coil.

A method for localized proton spectroscopy of the human brain is proposed which can be used with a standard transmit/receive planar surface coil producing an inhomogeneous RF field. Water suppression is accomplished by a train of full passage adiabatic pulses with optimized frequencies and delays, which account for variation in the water resonance frequency and the spin-lattice relaxation time. The robust method requires minimal pulse calibration and provides high-quality spectra even at very short echo times and in the absence of outer volume saturation and, therefore, is well suited for clinical in vivo spectroscopy. Performance of the method is demonstrated on a test object and on MR spectra from the human brain at 3 T.

Adult↗

Metabolic changes in rat brain after prolonged ethanol consumption measured by 1H and 31P MRS experiments.

1. In vivo 1H and 31P magnetic resonance spectroscopy techniques were applied to reveal biochemical changes in the rat brain caused by prolonged ethanol consumption. 2. Three models of ethanol intoxication were used. 3. 1H MRS showed a significant decrease in the concentration of myo-inositol in the brain of rats fed with 20% ethanol for 8 weeks. This change is consistent with perturbances in astrocytes. On the other hand, N-acetyl aspartate and choline content did not differ from controls. 4. 31P MRS did not reveal any significant changes in the high-energy phosphates or intracellular free Mg2+ content in the brain of rats after 14 weeks of 20% ethanol drinking. The intracellular pH was diminished. 5. By means of a 31P saturation transfer technique, a significant decrease was observed for the pseudo first-order rate constant k(for) of the creatine kinase reaction in the brain of rats administered 30% ethanol for 3 weeks using a gastric tube. 6. The 1H MRS results may indicate that myo-inositol loss, reflecting a disorder in astrocytes, might be one of the first changes associated with alcoholism, which could be detected in the brain by means of in vivo 1H MRS. 7. The results from 31p MRS experiments suggest that alcoholism is associated with decreased brain energy metabolism. 8. 31P saturation transfer, which provides insight into the turnover of high-energy phosphates, could be a more suitable technique for studying the brain energetics in chronic pathological states than conventional 31P MRS.

Adenosine Triphosphate↗

Physicochemical properties of normal articular cartilage and its MR appearance.

Basic physical and physicochemical properties of articular cartilage are correlated with the MR parameters of this tissue. From these parameters, the typical appearance of cartilage in MR images is deduced. Some practical implications for clinical utilization of MRI of articular cartilage are summarized.

Cartilage, Articular↗

Magnetic resonance imaging of articular cartilage and evaluation of cartilage disease.

Clinical magnetic resonance imaging of articular cartilage is possible by using techniques that offer high contrast between articular cartilage and adjacent structures in reasonable examination times. The fat-suppressed, three-dimensional, spoiled gradient-echo sequence has been reported to be accurate and reliable, and the addition of this sequence to a routine examination does not significantly compromise patient throughput. Fast spin-echo imaging also shows promise in the clinical evaluation of articular cartilage, because the newer, stronger-gradient systems allow thinner slice acquisition with two-dimensional sequences. Together, these sequences allow the evaluation of intrachondral lesions and surface defects. Furthermore, quantitative measurements of cartilage volume for follow-up studies are possible with the use of the fat-suppressed, three-dimensional, spoiled gradient-echo sequence.

Cartilage Diseases↗

The role of relaxation times in monitoring proteoglycan depletion in articular cartilage.

Various proton relaxation times (T2, T1rho, and gadolinium-diethylene triamine pentaacetic acid [Gd-DTPA]-enhanced T1) were measured in articular cartilage in vitro at 3 T to assess their role in visualizing proteoglycan depletion. Cartilage-bone specimens were obtained from patients who underwent total joint replacement and got a double dose of Gd-DTPA 2 hours prior surgery. In these specimens, regions of mechanically undamaged cartilage having a decreased content of proteoglycans showed about 15% lower T1 values compared with apparently normal cartilaginous tissue. The expected increase of the T2 relaxation time was not observed in these regions. On the other hand, the T2 and, to a lower degree, T1 relaxation times were found to be increased in regions of cartilage fibrillation. The T1rho relaxation times obtained were slightly longer than the corresponding T2 values, but both parameters showed almost identical spatial distributions. J. Magn. Reson. Imaging 1999;10:497-502.

Cartilage, Articular↗

MRI visualization of proteoglycan depletion in articular cartilage via intravenous administration of Gd-DTPA.

The effect of intravenous administration of gadolinium diethylenetriamine-pentaacetic acid (Gd-DTPA) on MR images was studied in vitro, using pathologic osteochondral specimens removed during surgery for total endoprosthesis, and in vivo, on a group of volunteers. In ex vivo specimens, lesions of different shape having lower T1 were detected which corresponded to areas with depleted proteoglycans found histologically. In vivo experiments on young volunteers showed that the time course of cartilage enhancement was different for different anatomies. The time for maximum enhancement ranged from 45 min for the ventral femoral condyle to 270 min for patellar cartilage.

Adult↗

Creatine kinase reaction rates in rat brain during chronic ischemia.

Creatine kinase reaction rates were measured by magnetisation transfer technique in the brain of healthy adult and aged rats and in the rats with mild or severe chronic cerebral ischemia. These measurements indicated that the rate constant of the creatine kinase reaction is significantly reduced in the case of chronic brain ischemia in aged rats. In contrast, occlusion of both carotid arteries in adult rats produced a slight increase in the reaction rate 4 weeks after occlusion. At the same time, corresponding conventional phosphorus magnetic resonance spectra showed negligible changes in signal intensities.

Aging↗

Motion artifacts reduction in DWI using navigator echoes: a robust and simple correction scheme.

NMR signal phase variation caused by macroscopic motion of an object during application of the diffusion gradient is a well-known effect in diffusion-weighted imaging (DWI) using the standard pulsed gradient spin-echo sequence (PGSE). This phase error causes severe ghost artifacts in the output image when phase encoding techniques, such as two dimensional Fourier transform (2DFT) imaging, are used. One possible way to eliminate the motion effects is the navigator echo technique. The method is based on estimating the phase error from the navigator echo and using it for the correction of the image echo. The phase errors (zero and first order) for the phase correction of the image echo are usually evaluated from the navigator echo after Fourier transform (FT) in the readout direction, correcting for both translation and rotation. We present here a simple algorithm which enables evaluation and correction in the time domain of phase errors induced by motion. This approach has the advantage of improved correction of motional artifacts and minimized sensitivity to noise and inaccurate setting up of the experiment.

Algorithms↗