PubMed Health⌕ Search

Biomedical subjects

V Moles

Publications and source records attributed to V Moles.

5 recordsLinked to original sources

Success with coronary angioplasty as seen at demonstrations of procedure.

To assess the real-life results of coronary angioplasty, unidentified participants made notes on 104 cases demonstrated live at twelve international angioplasty courses in 1991. The initially planned procedure was successful in 73% with crossover to another device in 20% for an ultimate success rate of 93%. Interventions lasted an hour on average and two devices on average were used per artery tackled. Rates of success and of complication necessitating reintervention were, for balloon angioplasty (57 cases) 81% and 19%, for directional atherectomy (16 cases) 75% and 0%, for the Rotablator (12 cases) 42% and 42%, for stent implantation (10 cases) 100% and 0%, for excimer laser angioplasty (6 cases) 17% and 33%, and for Rotacs recanalisation (3 cases) 67% and 0%, respectively. The complications were occlusions (threatened, acute, or delayed) and they were usually treated by balloon angioplasty or a stent. No death or myocardial infarction was reported. The observer attending the demonstration tended to take a less favourable view of the outcome than the clinician doing the procedure and in general the results of coronary angioplasty seemed inferior to those reported in journals. Interventions done before an audience will be unusually stressful but this will be outweighed by the fact that difficult cases with a low probability of success are rarely tackled during live courses. This survey suggests that conventional balloon angioplasty, complemented by stent implantation in selected cases, is the treatment of choice.

Adult↗

Influence of the rt-PA dose (1 mg/kg versus 1.5 mg/kg) and duration of administration on the patency of infarct-related coronary arteries in 81 patients.

This open study compared the efficacy and side effects of two dose regimens of intravenous rt-PA initiated before the fifth hour after the onset of myocardial infarction. The first 40 patients (group A) received 1 mg/kg of rt-PA infused over 90 minutes, including a 10-mg initial bolus. The following 41 patients (group B) received 1.5 mg/kg (20-mg initial bolus, 60% over 60 minutes and 40% over 120 minutes). Noninvasive clinical, electrocardiographic, and biochemical parameters of reperfusion were recorded systematically, along with serial measurements of fibrinogen and hemoglobin levels. Coronary arteriography and left ventriculography were performed at the 48th hour or earlier, on an emergency basis, in the absence of signs of reperfusion, or if there were clinical and ECG signs of rethrombosis. Patency of the infarct-related artery (TIMI grades 2 and 3) was achieved in 55% of the group A patients vs. 83% of the group B patients (p less than .01). Twelve emergency coronary arteriographies were performed in each group. No significant difference was observed in the ejection fraction (48% in group A vs. 52% in group B). The peak CPK level was similar in both groups, but the peak occurred earlier in group B (p less than .001). There was no statistically significant difference between the two dose regimens in terms of reduction in fibrinogen or plasminogen levels. Two deaths occurred in group A vs. one death in group B. No cerebrovascular accidents occurred in either group.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

Intracoronary electrocardiogram during coronary angioplasty.

This prospective study examines the data derived from the intracoronary electrocardiogram (ECG) (derived from the coronary guide wire) compared with that from four standard surface leads (I, II, III, and V2) in documenting myocardial ischemia during coronary angioplasty. Intracoronary and surface ECGs were simultaneously recorded in 300 consecutive patients (mean age 59 +/- 10; range 33 to 80 years; 246 males [82%] during coronary angioplasty in 368 lesions (167 left anterior descending [46%], 85 left circumflex [23%], 107 right coronary arteries [29%], and nine bypass grafts [2%]), before balloon inflation, at 1 minute of inflation, and at the end of the procedure. ST segment changes (greater than 0.1 mV) were observed in the intracoronary ECG in 306 lesions (83%) (151 left anterior descending [88%], 75 left circumflex [89%], and 80 right coronary arteries [73%]) versus in 245 lesions (67%) in the surface ECG (126 left anterior descending [73%], 43 left circumflex [47%], and 76 right coronary arteries [70%]; [p less than 0.0001]). The mean ST segment shift was 0.5 +/- 0.4 mV in intracoronary and 0.1 +/- 0.2 mV in standard leads (p less than 0.0001). ST elevation was seen in 97% of cases with intracoronary ECG changes versus in 83% with surface ECG changes. The remainder had ST depression. A total of 48 lesions (13%) did not produce ECG changes and 62 (16%) had silent ischemia. In 75 lesions (21%), ECG changes were seen only in the intracoronary ECG, compared with 14 lesions (4%) with changes only in the surface ECG (p less than 0.001).(ABSTRACT TRUNCATED AT 250 WORDS)

Angioplasty, Balloon, Coronary↗

Coronary angioplasty with second generation Monorail catheters.

The Monorail system (Schneider) consists of a balloon catheter in which the guidewire passes through the balloon itself, exits the catheter proximal to the balloon, and runs alongside its small shaft (3 French) through the length of the guiding catheter. It offers distinct advantages over conventional systems of coronary angioplasty. It facilitates contrast injections and permits rapid balloon exchanges. This system was used for coronary angioplasty in 273 unselected consecutive patients (age 59 +/- 10, mean 35 to 73 years). There were 216 patients (84%) undergoing single-vessel and 57 patients (16%) with multi-vessel coronary angioplasty. A total of 335 coronary stenoses were dilated, which included 35 total occlusions. The size of balloon used ranged from 2.0 to 4.25 mm (3.0 +/- 0.5 mm) and the severity of stenosis was 85 +/- 11%. Technical success was defined as a residual stenosis of less than 50% as determined angiographically. Clinical success was defined as technical success, and absence of a major inhospital complication defined as absence of myocardial infarction, lack of need for coronary arterial bypass surgery, and survival. The Monorail system was technically successful in 294/300 stenotic lesions (98%). It was clinically successful for 281 lesions (94%). Of the 35 total occlusions, technical success was obtained in 25 (71%). The residual stenosis of successful cases was 26 +/- 21%. The Monorail system was also successful in 5 patients with stenosis of more than 90% in whom conventional systems failed. The complications included acute occlusion causing acute myocardial infarction in 13 cases (5%), emergency coronary arterial bypass surgery in 1 patient (0.4%), and death in 4 patients (1.5%).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Early experience with coronary stenting.

From April 1988 to December 1991, we implanted 75 coronary stents (29 self-expanding and 46 balloon expandable) in 62 patients. All had New York Heart Association class II to IV angina, and 11 (18%) had prior coronary artery bypass grafting (CABG). Thirty nine patients (63%) had 1 vessel disease, and 23 (37%) had multivessel disease. The mean left ventricular ejection fraction was 63 +/- 11%. The indications for coronary stenting were acute post percutaneous transluminal coronary angioplasty (PTCA) occlusion in 45 (73%) (bail out stenting) and restenosis in 17 (24%) (elective stenting). There were 52 single stent (84%), 7 double stent (11%), and 3 triple stent procedures (5%). The mean stent diameter was 3.8 +/- 0.5 mm, and the mean stent length 21 +/- 7 mm. The attempted vessels were the left main coronary artery in 2(3%), left anterior descending coronary artery in 27 (44%), left circumflex coronary artery in 8 (13%), right coronary artery in 17 (27%), and a saphenous vein graft in 8 (13%). Technical success was achieved in 74 stent implantations (98%). Technical failure occurred in 1 case with a self expanding stent because of inability to reach the lesion. In hospital complications (mean hospital stay 10 +/- 10, range 2-60 days) included temporary stent occlusion in 2 patients (3%) treated by balloon dilatation and thrombolysis with intravenous urokinase, permanent stent occlusion in 5 patients (8%), Q-wave infarction in 5 patients (8%), CABG in 4 patients (11%), and death in 3 patients (5%). At least 1 major complication (Q wave infarction, CABG, or death) occurred in 8 patients (13%).(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗