PubMed Health⌕ Search

Biomedical subjects

V Nève

Publications and source records attributed to V Nève.

6 recordsLinked to original sources

Lung and thorax development during adolescence: relationship with pubertal status.

The aim of the present study was to define reference values for lung volumes and the lung transfer factor for carbon monoxide (TL,CO) for an adolescent population using thoracic volume index (TVI) and an index of pubertal stage in order to account for the variation in growth pattern between adolescents. TVI, pubertal stage by Tanner scale (PST), time since menarche, functional residual capacity measured using the helium-dilution technique, vital capacity, total lung capacity and TL,CO measured using a steady-state method were determined in 51 males (aged 13-20 yrs; PST T3-T5) and 52 females (aged 13-18 yrs; PST T2-T4; all but three had already undergone menarche). In male adolescents, height, weight, TVI, lung volumes and TL,CO increased with age. This was not the case in female adolescents. In males, the TVI was the independent variable that best correlated with pulmonary volumes. In females, height was the independent variable that best correlated with pulmonary volumes. In both sexes, the variable that best correlated with TL,CO was PST, associated with height in males. This cross-sectional study provides prediction equations for lung volumes and the lung transfer factor for carbon monoxide taking into account thoracic volume index and pubertal stage. It shows that, in adolescent males, lung and thoracic development occurs during and until the end of puberty. Conversely, in adolescent females, lung development is almost finished following menarche.

Adolescent↗

Overdistension in ventilated children.

Ventilating patients with acute respiratory failure according to standardized recommendations can lead to varying volume-pressure (V-P) relationships and overdistension. Young children may be more susceptible than adults to overdistension, and individual evaluation of the effects of ventilator settings is therefore required. Three studies have applied indices for the detection of overdistension to dynamic V-P curves in ventilated children. Two of those studies compared these indices to those obtained using a reference technique ([quasi]-static V-P curves), and suggested that the c coefficient of a second order polynomial equation (SOPE) and the ratio of the volume-dependent elastance to total dynamic elastance (%E2) were suitable indices for estimating overdistension.

Animals↗

Ventilator-induced overdistension in children: dynamic versus low-flow inflation volume-pressure curves.

We applied to 20 paralyzed ventilated children (0.15 to 14.3 yr, six with acute respiratory distress syndrome [ARDS]) the low-flow inflation (LFI) technique providing quasi-static volume-pressure (V-P) curves and compared the assessment of overdistension (OD) on dynamic and LFI (reference) inspiratory V-P curves. Dynamic curves were obtained at the airway opening during regular constant flow ventilation (Servo 300). Then LFI curves were obtained. Two analyses were performed: First, the nonlinear coefficient c of a second order polynomial equation (SOPE) fitted to dynamic data obtained during constant flow was compared with the c of SOPE fitted to LFI curve (within tidal volume [VT]). Second, the dynamic C20/C (ratio of compliance of the last 20% of the curve (C20) to total compliance [C]) was compared with the determination of the upper inflection point (UIP) on the LFI curve. OD was defined as a negative value of c, a C20/C < 0.80, an UIP included within the VT range for that child during regular ventilation. Using LFI V-P curves as reference, SOPE offered a better detection of OD than dynamic C20/C or the determination of the UIP by graphical means. Indeed the first analysis showed a substantial agreement (kappa 0.75) between dynamic c and LFI c detection of OD whereas the second analysis showed a poor agreement (kappa 0.22) between C20/ C and LFI detection of the UIP. In conclusion, quasi-static V-P curves can easily be obtained in children with the LFI technique. SOPE offers a good detection of OD on dynamic and LFI V-P curves but the C20/C index seems to be an inadequate measure of OD.

Adolescent↗

Longitudinal clinical and functional pulmonary follow-up after megatherapy, fractionated total body irradiation, and autologous bone marrow transplantation for metastatic neuroblastoma.

BACKGROUND: A prospective follow-up was undertaken to document longitudinal changes in lung function in children with neuroblastoma treated with the Lyon-Marseille-Curie-East of France Group protocol, consisting of high-dose chemotherapy schedules in combination with total body irradiation (TBI) and autologous bone marrow transplantation (ABMT), to determine the extent and timing of any changes seen and to describe late clinical and functional pulmonary sequelae. PROCEDURES: Eighteen children (1.5-6.9 years of age at TBI) performed pulmonary function tests (PFTs). These included measurement of functional residual capacity (FRC) to assess lung growth and dynamic lung compliance (CLdyn) and lung transfer factor for CO (TLCO) for evaluation of distal bronchi and/or interstitial abnormalities. RESULTS: The clinical follow-up showed that bronchopulmonary symptoms occurred in 12 children. Three of them were clinically severely incapacitated. Serial PFTs showed an initial decrease of all mean values 6 months after TBI, with improvement in mean values of FRC and TLCO at 1 year. Thereafter, a significant decrease of mean FRC and CLdyn was observed from 2 years to 4 years after TBI with preservation of TLCO, suggesting restrictive ventilatory defects rather than pulmonary fibrosis. Individual analysis showed PFT defects in 100% of children 4 years after TBI. There was a higher incidence of lung pathology after two blocks of high-dose chemotherapy than after one block (100% versus 40%) and more severe sequelae. However these children had residual disease present after induction associated with lower baseline PFT. CONCLUSIONS: PFT defects were found in all children 4 years after TBI-ABMT, but they remained within acceptable limits except in very young children.

Antineoplastic Combined Chemotherapy Protocols↗

Measurement of respiratory mechanics in paediatric intensive care: in vitro assessment of a pulmonary function device.

OBJECTIVE: To evaluate a recently developed and manufactured device for monitoring respiratory parameters in mechanically ventilated children. DESIGN: In vitro study using a lung model. SETTING: University paediatric intensive care unit. MATERIAL AND INTERVENTIONS: Evaluation of the accuracy of volume and pressure measurements, of the determination of respiratory system compliance (10 to 30 ml/cmH2O) and of resistance (20 and 50 cmH2O/l per s) by the inflation technique (volume- and pressure-controlled mode of ventilation); assessment of interobserver agreement for compliance (10, 15 ml/cmH2O) and resistance (20, 50 cmH2O/l per s) determinations (ANOVA, intraclass correlation coefficient). MEASUREMENTS AND RESULTS: The accuracy of volume measurements (No.1 Fleisch pneumotachograph) was < or = 5 % of true volumes up to 11 (Flow: 30 l/min) even after the introduction of an endotracheal tube. The accuracy of pressure measurements up to 70 cmH2O was < or = 2.5% of the true values. Coefficients of variation of volume and pressure measurements were < 2%. The accuracy of compliance and resistance determinations was, respectively, < or = 17 and 25% of the true values. No significant observer effect was found on compliance and resistance determinations. Indeed, mean differences in compliance and resistance determinations by pairs of observers were < 1%. Intraclass correlation coefficients were > 0.98. CONCLUSIONS: The measuring error of volume, pressure, compliance and resistance determined using this monitoring system seems acceptable for monitoring purpose. Moreover, use of this system by members of the medical team can be recommended since results obtained by observers, even untrained ones, were similar. In vivo evaluation is now needed.

Airway Resistance↗