Selenium concentrations in serum of individuals with liver diseases (cirrhosis or hepatitis): relationship with some nutritional and biochemical markers.

Serum concentrations were measured in individuals (n = 50) with liver diseases (cirrhosis and hepatitis) by hydride generation atomic absorption spectrometry in a cross-sectional study. Mean serum selenium levels determined in patients with cirrhosis (n = 12) or with hepatitis (n = 38) were significantly lower (P<0.01) than those measured in control groups mainly due to a decreased liver function. Mean serum selenium concentrations were significantly lower in cirrhotic individuals when compared with patients with hepatitis (P<0.05). Therefore, the severity of the live injury is a factor conditioning the impairment in the selenium body status observed in individuals with hepatopathies. In hepatic patients serum total cholesterol levels showed a significant correlation with serum selenium concentrations (r=0.912, P<0.05) demonstrating the important role of selenium as an antioxidant agent; similarly, gamma-glutamic-transferase levels were significantly correlated with the serum selenium levels (r=-0.803, P<0.05) indicating that when the intensity of the hepatic injury increases (enhancement in serum GGT levels) concomitantly the serum selenium levels decrease significantly. No significant relationships between serum selenium levels and sex or age of patients were observed.

Adult↗

Multicentric reference values for some quantities measured with the Elecsys 2010 analyser.

Several clinical laboratories in different regions of Spain have shared the search for reference individuals and the production of reference values for quantities concerning thyrotropin, non-protein bound thyroxine, triiodothyronine, cobalamines and folates, using an Elecsys 2010 analyser. All the logistic work has been done in co-operation with the supplier of the analyser (Roche Diagnostics España, S.L., Barcelona). The reference limits produced in the virtual laboratory are in fact derived from the blend of reference values obtained by each laboratory. The multicentric reference limits were estimated according to the recommendations of the International Federation of Clinical Chemistry. The work done represents a model of co-operation between the in vitro diagnostic industry and clinical laboratories for the production of reference values.

Reference Standards↗

Serum and urine selenium concentrations as indicators of body status in patients with diabetes mellitus.

Serum and urine selenium levels were determined in patients with diabetes by hydride generation atomic absorption spectrometry. Mean serum selenium concentrations measured in patients with diabetes mellitus (64.9 +/- 22.8 micrograms/l) were significantly lower than those determined in the control group (74.9 +/- 27.3 micrograms/l) (P < 0.05). Mean serum selenium concentrations were not significantly different between the two groups of diabetic patients considered (P > 0.05). Mean urine selenium concentration in diabetic patients (18.8 +/- 10.7 micrograms/l) were not significantly different from those measured in the control group (20.2 +/- 10.1 micrograms/l) (P < 0.05). No significant differences in serum and urine selenium levels were found if related to sex of patients (P > 0.05). Application of linear regression analysis to serum and urine selenium levels and patients' age showed a non-statistically significant correlation (P > 0.05). Given the marked overlap between the two ranges of the populations, the predictive values of serum selenium in diabetic patients are low.

Adolescent↗

Serum and urine selenium concentrations in patients with cardiovascular diseases and relationship to other nutritional indexes.

Serum and urine selenium levels were determined in patients with cardiovascular diseases by hydride generation atomic absorption spectrometry. Mean serum Se concentrations measured in patients with acute myocardial infarction (AMI; n = 32) or with ischemic cardiomyopathy (n = 50) were significantly lower than those determined in control groups. In AMI patients, serum triglyceride levels showed a positive significant correlation with the serum Se concentration (r = 0.59, p < 0.05). This result reinforces the important role of Se as an antioxidant agent in this disease. Mean urine Se concentrations of AMI patients (n = 33) were also significantly lower to those determined in the control group (p < 0. 05). This reaction of the organism contributes to regulate the Se homeostasis to keep the body Se status as high as possible.

Adult↗

Urine arsenic concentrations in healthy adults as indicators of environmental contamination: relation with some pathologies.

Arsenic concentrations were determined in 126 urine samples by hydride generation atomic absorption spectrometry. Samples were mineralized with nitric acid in a thermostated mineralization block. This technique was compared with a method that involves mineralization in a microwave digestion bomb. A mean recovery percentage of 100.80 +/- 5.57% was obtained. The relative standard deviation ranged from 1.7 to 10.52%. It was found that subject sex and age did not affect urine As levels (P > 0.05). The mean urine As levels in patients with hepatic injury (4.24 +/- 1.98 micrograms/l), diabetes (3.44 +/- 2.36 micrograms/l) and myocardial infarction (3.64 +/- 1.85 micrograms/l) were not statistically different (P > 0.05) to that found in the control group (healthy subjects) (3.68 +/- 2.27 micrograms/l). This result could be related to the fact that the regulation of As in the human organism is independent of these diseases. Measured As concentrations in the eight basic health zones of the study area were not statistically different (P > 0.01). This fact demonstrates the existence of a similarly low environmental As distribution in coastal and mountainous zones.

Adult↗

Serum selenium levels as indicators of body status in cancer patients and their relationship with other nutritional and biochemical markers.

A cross-sectional study of serum selenium levels in patients (n = 59) with different types of cancer from southeastern Spain was carried out using hydride generation atomic absorption spectrometry. The subjects were divided into four groups according to the cancer location (respiratory, digestive, haematological and gynaecological groups). Serum selenium levels in all patients (54.41 +/- 24.80 mg/l) were significantly lower (P < 0.001) than those determined in control groups [healthy subjects from the same area (n = 130) and institutionalized elderly people (n = 93)]. Mean serum selenium concentrations were not significantly different among the four groups considered (P > 0.05). Linear regression analyses performed on serum selenium levels and biochemical markers (total cholesterol, triglycerides, transaminases, uric acid and urea) did not establish any statistically significant correlation (P > 0.05). No significant relationships between serum selenium concentrations and sex or age of patients was observed (P > 0.05). Given the marked overlap between the two ranges of the populations (the means are within approx. 1/2 S.D.) the predictive values of serum selenium are low. Thus, there is indeed a statistical significance between the means, but selenium cannot be used to determine whether or not a patient has cancer disease.

Adult↗

Zinc and copper concentrations in serum from Spanish women during pregnancy.

A cross-sectional study of serum zinc (Zn) and copper (Cu) levels in 31 healthy pregnant women and 51 healthy, nonpregnant controls living in the Mediterranean area of Granada, Spain, was performed. The subjects were divided into two groups: Group A, consisted of pregnant women in three categories according to the trimester of pregnancy, and Group B consisted of nonpregnant women acting as controls. In pregnant women, serum Zn levels were found from 0.300-1.340 mg/L and serum Cu from 0.936-2.304 mg/L, whereas in the nonpregnant women group, the mean serum levels were 0.947+/-0.265 mg/L for Zn and 1.092+/-0.365 mg/L for Cu. Serum Zn progressively decreased with gestation. Mean Zn levels were 0.829+/-0.253, 0.846+/-0.329, and 0.620+/-0.142 mg/L, corresponding to the first, second, and third trimesters of pregnancy, respectively. Serum Zn concentrations were significantly lower in pregnant women as compared to controls: 0.712+/-0.236 mg/L vs 0.947+/-0.265 mg/L, respectively (p < 0.05). In contrast, Cu levels increased with period of gestation from 1.053+/-0.498 mg/L in the first trimester to 1.616+/-0.304 mg/L in the second and 1.689+/-0.344 mg/L in the third. Serum Cu levels in the second and third trimesters of pregnancy were significantly higher (p < 0.05) than those determined during the first trimester and for nonpregnant controls. Both Zn and Cu during pregnancy did not appear to be dependent on the subject's age (p > 0.05).

Adult↗

Serum zinc and copper concentrations and Cu/Zn ratios in patients with hepatopathies or diabetes.

The serum zinc and copper levels, as well as Zn/Cu ratios, were determined in 30 patients (18 with diabetes and 12 with hepatopathies) and compared to healthy-age matched controls by atomic absorption spectrometry. Serum Zn (0.946 +/- 0.302 mg/l) and Cu (0.952 +/- 0.355 mg/l) concentrations were not significantly different in patients with hepatopathies as compared to controls (p > 0.05). Serum Zn concentrations (0.778 +/- 0.164 mg/l) were significantly lower in diabetic patients than those determined in controls (p < 0.01). In contrast, Cu levels (0.987 +/- 0.305 mg/l) were not significantly different (p > 0.05) than in controls. Serum Cu/Zn ratios were not significantly different in patients with diabetes or hepatopathies than those measured in healthy controls (p > 0.05). In patients, no statistically significant differences were observed in the Zn, Cu and Cu/Zn with respect to sex (p > 0.05) or age (p > 0.05).

Adolescent↗

Downmodulation of HLA class I expression by dexamethasone in MCF-7 cell line.

Several reports have shown the importance of MHC class I antigens in enabling the host to regulate tumour growth in vivo. Glucocorticoid hormones have strong immunosuppressive effects and are known to be regulators of gene transcription. In this report the expression of Major Histocompatibility Complex (MHC) class I antigens in six breast carcinoma cell lines have been studied before and after treatment with the synthetic glucocorticoid dexamethasone. Hence, HLA class I expression in the MCF-7 cell line was down-regulated in the presence of dexamethasone. This down-modulation of expression appeared to be mediated by transcriptional mechanisms, as revealed by HLA-class I mRNA levels.