Pacemaker lead extraction with the laser sheath: results of the pacing lead extraction with the excimer sheath (PLEXES) trial.

OBJECTIVES: The purpose of this study was to evaluate the safety and effectiveness of pacemaker lead extraction with the excimer sheath in comparison to nonlaser lead extraction. BACKGROUND: Fibrotic attachments that develop between chronically implanted pacemaker leads and to the venous, valvular and cardiac structures are the major obstacles to safe and consistent lead extraction. Locking stylets and telescoping sheaths produce a technically demanding but effective technique of mechanically disrupting the fibrosis. However, ultraviolet excimer laser light dissolves instead of tearing the tissue attachments. METHODS: A randomized trial of lead extraction was conducted in 301 patients with 465 chronically implanted pacemaker leads. The laser group patients had the leads removed with identical tools as the nonlaser group with the exception that the inner telescoping sheath was replaced with the 12-F excimer laser sheath. Success for both groups was defined as complete lead removal with the randomized therapy without complications. RESULTS: Complete lead removal rate was 94% in the laser group and 64% in the nonlaser group (p = 0.001). Failed nonlaser extraction was completed with the laser tools 88% of the time. The mean time to achieve a successful lead extraction was significantly reduced for patients randomized to the laser tools, 10.1 +/- 11.5 min compared with 12.9 +/- 19.2 min for patients randomized to nonlaser techniques (p < 0.04). Potentially life-threatening complications occurred in none of the nonlaser and three of the laser patients, including one death (p = NS). CONCLUSIONS: Laser-assisted pacemaker lead extraction has significant clinical advantages over extraction without laser tools and is associated with significant risks.

Aged↗

Pacemaker interference with screening mammography.

In female pacemaker recipients undergoing screening mammography, the impact of a pulse generator placed in the pectoral region has yet to be reviewed. We evaluated mammograms from 74 female pacemaker patients aged 40 years and older. The pulse generator obscured a portion of the mammogram in 7 patients (12%). During pacemaker implantation in women, the potential for the pulse generator to interfere with screening mammography should be considered. Baseline mammography should be obtained or reviewed; in high risk patients a nonconventional location for the pulse generator may be appropriate.

Adult↗

Chondrosarcoma of the aorta: a rare source of bowel and lower extremity emboli.

Malignant aortic tumors occur infrequently. At least 70 cases of primary aortic malignancies have been reported in the literature. Within this group, chondrosarcoma is exceedingly rare, with only 1 case having been reported. An aortic chondrosarcoma developed in our patient and embolized to the small bowel and lower extremities. Although initially thought to arise from the abdominal aorta, this tumor, in fact, originated from the thoracic aorta. This case illustrates the need for complete aortic imaging when unexplained recurrent embolization occurs. In general, the survival rates with chondrosarcoma are diminished, but this patient survived 69 months after he was initially seen.

Aged↗

Angiotensin converting enzyme inhibitor therapy in severe postcardiotomy dysfunction: a prospective randomized study.

BACKGROUND: Occurrence of severe postcardiotomy dysfunction requiring prolonged postoperative support with intra-aortic balloon counterpulsation (IABP) and inotropes, complicating surgery for coronary artery disease and valvular heart disease carries important hospital morbidity and mortality. This study evaluated the impact of angiotensin converting enzyme inhibitor (captopril) therapy in these patients in the early postoperative period. METHODS: During a 5-year period, 298 patients with prolonged diminished cardiac output required support (> 48 to 72 hours) with IABP plus two or three inotropes. This cohort was randomized to two groups, group A (195 patients) who were continued on IABP and inotropes alone and group B (103 patients) who were given an angiotensin converting enzyme (ACE) inhibitor, captopril 48 to 72 hours postoperatively and continued on IABP and inotropes. RESULTS: Tissue perfusion and hemodynamic parameters improved (p < 0.0001) in group B with early termination of IABP (duration of support mean 86 hours in group B vs 169 hours in group A) and inotropes. Peak improvement in tissue perfusion and hemodynamic parameters correlated with decreased serum angiotensin converting enzyme levels. Hospital mortality occurred in 31% of patients in group A and 14.5% in group B. Morbidity complications developed in 37% of patients in group A and 20% in group B. The average length of hospital stay in group A was 27 days and 17 days in group B. Cardiac, pulmonary, infective, gastrointestinal, renal, and neurological complications were common in both groups. CONCLUSION: Administration of ACE inhibitors in the early postoperative period to patients with severe postcardiotomy dysfunction caused improvement in tissue perfusion with decreases in mortality, morbidity, and length of hospital stay. These drugs, by effectively limiting physiological effects induced by renin angiotensin-aldosterone axis and other mechanisms, caused recovery of stunned myocardium. More randomized trials are needed before recommending these drugs for routine use in similar patients.

Angiotensin-Converting Enzyme Inhibitors↗

Endothelial cell adaptation to chronic thrombosis.

BACKGROUND: The autogenous vein graft has proven to be the most durable conduit in lower extremity vascular bypass grafts. Failures due to thrombosis, intimal hyperplasia, and progression of atherosclerotic disease commonly plague the vascular surgeon. Part of the ability of vein grafts to provide a nonthrombogenic surface relies on the capability of the endothelial cell to produce prostacyclin, a potent vasodilator and inhibitor of platelet aggregation. Once a graft fails and thromboses, little is known as to the effects of the thrombus on the function and morphology of endothelial cells. Earlier studies by this laboratory demonstrated the ability of arterialized canine vein grafts to recover function after 5 days of exposure to thrombus. This investigation sought to explore the limits of endothelial cell viability and recovery to extended periods of thrombosis. METHODS: Using a canine model of arterialized vein grafts, prostacyclin production (measured as 6-keto-PGF1a) was assessed in an ex vivo perfusion system from grafts exposed to thrombus for 10 days (group I) and 20 days (group II). Both groups underwent thrombectomy and a recovery period of 30 days. The grafts were perfused with Hanks' balanced salt solution and samples were obtained at 5 and 30 minutes to determine prostacyclin levels. Arachidonic acid was then added to a new perfusate of Hanks' solution and samples were again obtained at 5 and 30 minutes. Results were expressed as PGF/graft area (cm2/min). Representative samples of each graft underwent scanning electron microscopy. RESULTS: Without arachidonic acid, prostacyclin production of group II (20 day) grafts was greater than group I (10 day) grafts at 5 minutes of perfusion (4.31 versus 2.42, P = 0.08) and at 30 minutes (1.86 versus 0.95, P = 0.02). In response to the addition of arachidonic acid both groups increased prostacyclin production (group I, P = 0.004; group II, P = 0.12). A comparison was made between prostacyclin production at baseline and after addition of arachidonic acid. Group I grafts demonstrated a greater percent increase in prostacyclin production compared to group II (385% versus 229%, P = 0.01). Scanning electron microscopy showed no differences in endothelial coverage between the study groups. CONCLUSIONS: These results demonstrate that although endothelial cells are able to recover a basal level of prostacyclin production, the response to substrate stimulation diminishes with increased exposure time to thrombus. This diminished response may be important in understanding the ability of vein grafts to survive after a period of thrombosis.

Adaptation, Physiological↗

The effect of nonisodiametric design on the ease of extracting chronically implanted pacemaker leads.

Extracting permanently implanted transvenous pacemaker leads is often difficult because a fibrous sheath tends to trap the lead at various points along its course. Because many leads have bulbous or nonisodiametric portions, extraction may be rendered even more troublesome, because it is difficult to pull the larger portion through the narrow areas of the sheath. Furthermore, forceful extraction may have dire consequences, such as cardiac laceration. A study was undertaken in animals to evaluate the effect of lead isodiametricity on lead extraction. The results show that any increase in the diameter of the lead tip greatly reduces the ease of its removal. Consequently, leads designed to be isodiametric throughout their entire lengths will greatly enhance their removability.

Animals↗