PubMed Health⌕ Search

Biomedical subjects

V Porta

Publications and source records attributed to V Porta.

15 recordsLinked to original sources

Clinical pharmacokinetics of lyophilized recombinant human erythropoietin-alpha following single-dose subcutaneous administration in premature newborns.

OBJECTIVE: The aim of this study was to determine pharmacokinetic parameters after subcutaneous administration of a single dose (400 IU/kg) of lyophilized recombinant human erythropoietin-alpha (rhEPOalpha) to preterm newborns. The parameters determined were: maximum concentration (C(max)), time to reach maximum concentration (T(max)), absorption half-life (t(l/2abs)), volume of distribution (Vd), elimination half-life (t(l/2el)), clearance (C(L)), constant of elimination (k(el)) and area under the 0-72 h curve (AUC(0-72). METHODS: The study group comprised 20 premature newborns (eight males and 12 females) delivered in the Teaching Hospital, University of São Paulo. The inclusion criteria were birth weight < 1500 g or gestational age < or = 34 weeks, and clinical and hemodynamic stability. Serum erythropoietin (EPO) concentration was determined before and 1, 4, 6, 12, 24,48 and 72 h after subcutaneous administration of 400 IU/kg rhEPOalpha, and the pharmacokinetic parameters were calculated. RESULTS: There was a significant difference in serum EPO concentration between t72 and t0 (p = 0.001). Mean values (range) of the pharmacokinetic parameters were as follows: C(max), 739.8 (188.0-1390.0) mIU/ml; T(max), 7.7 (4.0-12.0) h; t(l/2abs), 2.9 (0.8-4.8) h, V(d), 0.705 (0.23-1.73) 1/kg; t(l/2e1), 14.9 (8.7-36.1) h; C(L), 0.032 (0.014-0.066) 1/h; k(el), 0.0475 (0.0200-0.0700); and AUC(0-72), 19058.2 (7648.0-34701.5) mIU/ml per h. The Spearman test showed no correlation between the pharmacokinetic parameters analyzed and the characteristics of the population studied. CONCLUSIONS: Studies evaluating the effectiveness of therapy with recombinant human erythropoietin in premature newborns have used various doses, administered at intervals between 24 and 48 h. The kinetics of absorption measured in our study supports the use of 400 IU/kg within an interval of no less than 72 h, together with therapeutic control of the drug and evaluation of the erythropoietic response.

Absorption↗

Evaluation of the bioequivalence of capsules containing 150 mg of fluconazole.

Fluconazole is an antifungal agent. The purpose of this study was to evaluate bioequivalence of two commercial 150 mg capsule formulations of fluconazole available in the Brazilian market. The study was an open, randomized, two-period, two-group crossover trial with a 2-week washout interval. Blood samples were collected throughout a 96-h period after administration of reference product (R) and test product (T) to 28 fasting volunteers. A simple, accurate, precise and sensitive high-performance liquid chromatographic (HPLC) method with ultraviolet detection was developed and validated for quantification of fluconazole in plasma samples after liquid-liquid extraction. Bioequivalence between the products was determined by calculating 90% confidence intervals (90% C.I.) for the ratio of C(max), AUC(0-t) and AUC(0-infinity) values for the test and reference products, using logarithmic transformed data. The 90% confidence intervals for the ratio of C(max) (101.06-105.45%), AUC(0-t) (97.11-104.69%) and AUC(0-infinity) (97.96-103.36%) values for the test and reference products are within the 80-125% interval, proposed by FDA and EMEA. It was concluded that the two fluconazole formulations are bioequivalent in their rate and extent of absorption.

Adult↗

Simplified micromethod for the HPLC measurement of diclofenac in plasma.

A simple and sensitive micromethod based on HPLC is described for the measurement of diclofenac in 200 microliters plasma. A single extraction with dichloromethane in acidic medium was an essential clean-up step. Diclofenac and its internal standard (cyclohexendiphenyl propionic acid) was eluted at 3.3 and 6.5 min from a 4-micron C18 reverse-phase column using a mobile phase consisting of 0.75 M sodium acetate buffer, pH 5.0, and acetonitrile (55:45, v/v) at a flow rate of 0.9 ml/min with detection at 282 nm. The method, validated on the basis of parameters evaluated for the confidence limits of diclofenac measurements in spiked plasma, presented 1 ng/ml sensitivity, 10-10,000 ng/ml linearity, and 3.5% and 5.7% intra- and interassay precision, respectively. Peak plasma diclofenac levels ranging from 177 to 841 ng/ml and from 276 to 1008 ng/ml were obtained for two slow-release formulations. A wide range (1 ng/ml-3 micrograms/ml) was observed for plasma diclofenac levels of volunteers during a 24-h study period.

Chromatography, High Pressure Liquid↗