PubMed Health⌕ Search

Biomedical subjects

V Préat

Publications and source records attributed to V Préat.

At least 19 recordsLinked to original sources

Characterization of self-assembling copolymers in aqueous solutions using Electron Paramagnetic Resonance and Fluorescence spectroscopy.

Electron Paramagnetic Resonance and fluorescence spectroscopy have been used to determine the micropolarity and microviscosity of self-assembling systems based on mmePEG-p(CL-co-TMC) having different PEG chain lengths and different CL/TMC ratios and PEG/MOG/SA (45/5/50) polymers with different PEG chain lengths. Four reporter probes have been used: two spin probes, 16-doxyl stearic acid and 5-doxylstearic acid, and two fluorescent probes, pyrene and 1,3-bis(1-pyrenyl) propane (P3P). We found that the micelles based on mmePEG-p(CL-co-TMC) polymers are of a biphasic nature. The micelles are made of a hydrophilic corona with low viscosity while the core of the micelle is more hydrophobic and more viscous. The outer shell is made up of PEG chains, the hydrophobic part of the chains making the core. The partial hydration of the shell seems to lead to a looser chain network than that associated with deeper domains in the micelles. By contrast, in micelles composed of PEG/MOG/SA, there is no clear domain separation. This is consistent with a spatial configuration of random polymeric chains forming a loose network. In these micelles, the microviscosity is low and the hydrophobicity is high.

Caproates↗

Intestinal uptake and biodistribution of novel polymeric micelles after oral administration.

To determine the fate of polymeric micelles after oral administration, we investigated the possible transport of polymeric micelles across Caco-2 monolayers and their biodistribution in rats after per os administration of [14C]-labelled mmePEG750P(CL-co-TMC) micelles containing risperidone (BCS Class II drug). mmePEG750P(CL-co-TMC) was able to cross Caco-2 monolayer via a saturable transport mechanism. The oral bioavailability of the polymer was 40%. Polymeric micelles based on mmePEG750P(CL-co-TMC) showed very low clearance by the reticuloendothelial system (RES) and a renal excretion. A sustained release of risperidone was observed.

Administration, Oral↗

Encapsulation of amphotericin B in poly(ethylene glycol)-block-poly(epsilon-caprolactone-co-trimethylenecarbonate) polymeric micelles.

The aim of this work was to evaluate the potential of self-assembling poly(ethyleneglycol)(750)-block-poly(epsilon-caprolactone-co-trimethylenecarbonate)(4500) 50/50 copolymers (PEG-p(CL-co-TMC)) to solubilize amphotericin B in polymeric micelles and to disaggregate the drug to the less toxic monomeric form. Amphotericin B was encapsulated in the micelles upon dilution of a mixture of the liquid polymer and the drug in water. Its solubility was increased by two orders of magnitude depending on polymer concentration. The aggregation state of amphotericin B was decreased by PEG-p(CL-co-TMC). The preparation method and the loading of the polymeric micelles influenced it. The antifungal activity of the drug was reduced by encapsulation in the polymeric micelles whereas the onset of amphotericin B-induced hemolysis was delayed. PEG-p(CL-co-TMC) micelles could be an easy method for amphotericin B encapsulation.

Amphotericin B↗

DNA electrotransfer into the skin using a combination of one high- and one low-voltage pulse.

Electroporation is an effective alternative to viral methods to significantly improve DNA transfection after intradermal and topical delivery. The aim of the study was to check whether a combination of a short high-voltage pulse (HV) to permeabilize the skin cells and a long low-voltage pulse (LV) to transfer DNA by electrophoresis was more efficient to enhance DNA expression than conventional repeated HV or LV pulses alone after intradermal injection of DNA plasmid. GFP and luciferase expressions in the skin were enhanced by HV+LV protocol as compared to HV or LV pulses alone. The expression lasted for up to 10 days. Consistently, HV+LV protocol induced a higher Th2 immune response against ovalbumin than HV or LV pulses. Standard methods were used to assess the effect of electric pulses on skin: the application of a combination of HV and LV pulses on rat skin fold delivered by plate electrodes was well tolerated. These data demonstrate that a combination of one HV (700 to 1000 V/cm; 100 micros) followed by one LV (140 to 200 V/cm; 400 ms) is an efficient electroporation protocol to enhance DNA expression in the skin.

Animals↗

Influence of formulation excipients and physical characteristics of inhalation dry powders on their aerosolization performance.

The objective of this study was to determine the effects of formulation excipients and physical characteristics of inhalation particles on their in vitro aerosolization performance, and thereby to maximize their respirable fraction. Dry powders were produced by spray-drying using excipients that are FDA-approved for inhalation as lactose, materials that are endogenous to the lungs as albumin and dipalmitoylphosphatidylcholine (DPPC); and/or protein stabilizers as trehalose or mannitol. Dry powders suitable for deep lung deposition, i.e. with an aerodynamic diameter of individual particles <3 microm, were prepared. They presented 0.04--0.25 g/cm(3) bulk tap densities, 3--5 microm geometric particle sizes, up to 90% emitted doses and 50% respirable fractions in the Andersen cascade impactor using a Spinhaler inhaler device. The incorporation of lactose, albumin and DPPC in the formulation all improved the aerosolization properties, in contrast to trehalose and the mannitol which decreased powder flowability. The relative proportion of the excipients affected aerosol performance as well. The lower the bulk powder tap density, the higher the respirable fraction. Optimization of in vitro aerosolization properties of inhalation dry powders can be achieved by appropriately selecting composition and physical characteristics of the particles.

Administration, Inhalation↗

Topical gene transfer into rat skin using electroporation.

PURPOSE: To investigate whether electroporation can be used for topical gene delivery and for DNA expression in rat keratinocytes. METHODS: The localization of a fluorescent-labelled plasmid and the expression of a reporter gene (pEGFP-N1) coding for Green Fluorescent Protein (GFP) in stripped skin were assessed by Confocal Laser Scanning Microscopy (CLSM). RESULTS: The plasmid penetrated into the epidermis within minutes after electroporation and entered the keratinocyte cytoplasm within hours. A localized expression of GFP was observed for at least 7 days in the epidermis. Skin viability was not compromised by electroporation. CONCLUSIONS: Electroporation enhances the delivery, and hence the expression, of topically applied plasmid DNA on the skin. It could be a promising alternative method to administer DNA, particularly for DNA vaccines, in the skin in vivo.

Administration, Topical↗

[Drug and gene delivery using electrotransfer].

The use of a low intensity current (iontophoresis) and high voltage pulses (electroporation which permeabilizes lipid bilayers) has a potential for the administration of conventional and biotechnology-produced drugs. Iontophoresis and electroporation enhance transdermal delivery of drugs, including peptides and oligonucleotides. Electrochemotherapy, i.e., combination of a systemic or local delivery of a non-permeant cytostatic drug with electroporation, kills locally tumor cells. Recently, it has been shown that the local injection of a plasmid before electroporation increases significantly gene transfection. Hence, electrotransfer is a promising alternative for drug and gene delivery.

Animals↗

Electroporation-mediated delivery of 3'-protected phosphodiester oligodeoxynucleotides to the skin.

The feasibility of topical delivery in the skin of 3' end modified phosphodiester oligonucleotides using electroporation was investigated. Experiments were performed in vitro, using hairless rat skin. Five pulses of (200 V, 450 ms) were applied. The 3' end modifications of the 15 mer oligonucleotide were: (1) 3'-aminohexyl, (2) biotin, with a triethyleneglycol arm, (3) methylphosphonate links between nucleotides 13, 14 and 15, and (4) 2-O-methyl nucleotides at 13, 14 and 15 positions. All the modifications were efficient to protect the oligonucleotides against degradation in the skin. Electroporation increased the topical delivery of the 3' end-modified phosphodiesters by two orders of magnitude compared to passive diffusion, without significant differences between the derivatives. Oligonucleotide concentrations in the range of 1 microm could be achieved in the viable skin. The delivery of a phosphorothioate congener was lower than phosphodiester delivery due to the interaction of phosphorothioate with the stratum corneum. Consequently, 3' end-protected phosphodiesters could be an interesting alternative to phosphorothioate oligonucleotides for topical treatment of cutaneous diseases.

Administration, Topical↗

Transdermal delivery of macromolecules using skin electroporation.

PURPOSES: (1) To evaluate the feasibility of transdermal delivery of macromolecules by skin electroporation. (2) To assess the influence of the molecular weight of the permeant on transport and examine whether there exists a "cut-off" value of molecular weight. (3) To localize the transport pathways of the macromolecules in the skin. METHODS: FITC-dextran (FD) of increasing molecular weight (4.4, 12 and 38 kDa) were used as model macromolecules to study the extent of transport across hairless rats skin in vitro and to localize their distribution in the skin by confocal scanning laser microscopy. RESULTS: Electroporation enhanced the transport of the macromolecules as compared to passive diffusion. The transdermal delivery by skin electroporation of FITC and FD 4.4 was equivalent whereas transport of higher molecular weight FD was lower but significant. FITC and FD 38 were observed in the epidermis both around and in the keratinocytes. CONCLUSIONS: Transdermal and topical delivery of macromolecules of at least 40 kDa can be achieved by skin electroporation.

Administration, Cutaneous↗

Mechanisms of a phosphorothioate oligonucleotide delivery by skin electroporation.

Skin electroporation has great potential for topical delivery of oligonucleotides. Controled therapeutic levels of an intact phosphorothioate oligonucleotide (PS) can be reached in the viable tissue of the skin. The aim of this work was to investigate the transport mechanisms of a PS in hairless rat skin by electroporation, and hence to allow optimization of oligonucleotides (ONs) topical delivery. The pulsing condition used was five exponentially-decaying pulses of 100 V and 500 ms pulse time. The main mechanism of PS transport in the skin viable tissues during pulsing was electrophoresis. The electroosmosis contribution was negligible. Electrophoresis created within minutes a reservoir of PS in the skin viable tissues, which persisted within a therapeutic range of hours. A strong PS/stratum corneum interaction occurred.

Animals↗

Comparison of the effects of short, high-voltage and long, medium-voltage pulses on skin electrical and transport properties.

High-voltage pulses have been shown to increase rates of transport across skin by several orders of magnitude on a time scale of minutes to seconds. Two main pulse protocols have been employed to promote transport: the intermittent application of short ( approximately 1 ms) high-voltage (approximately 100 V across skin) pulses and a few applications of long (=100 ms) medium-voltage (>30 V across skin) pulses. In order to better evaluate the benefits of each protocol for transdermal drug delivery, we compared these two protocols in vitro in terms of changes in skin electrical properties and transport of sulforhodamine, a fluorescent polar molecule of 607 g/mol and a charge of -1. Whereas both protocols induced similar alterations and recovery processes of skin electrical resistance, long pulses of medium-voltage appeared to be more efficient in transporting molecules across skin. Skin resistance decreased by three (short pulses) and two (long pulses) orders of magnitude, followed by incomplete recovery in both cases. For the same total transported charge, long pulses induced faster and greater molecular transport across skin than short pulses. In addition, a greater fraction of the aqueous pathways created by the electric field was involved in molecular transport when using long pulse protocols. Transport was concentrated in localized transport regions (LTRs) for both protocols but LTRs created by long pulses were an order of magnitude larger than those formed by short pulses and the short pulses created an order of magnitude more LTRs. Overall, this study is consistent with the creation of fewer, but larger aqueous pathways by long, medium-voltage pulses in comparison to short, high-voltage pulses.

Adult↗

In vivo efficacy and safety of skin electroporation.

This article reviews the studies on skin electroporation carried out in vivo in animals and emphasizes its potential therapeutic applications for transdermal and topical drug delivery. In agreement with in vitro studies, transport across skin due to high-voltage pulses in vivo was shown to increase by orders of magnitude on a timescale of minutes. Increased transdermal transport was measured by systemic blood uptake and/or pharmacological response, and demonstrated for calcein, a fluorescent tracer, fentanyl, a potent analgesic and flurbiprofen, an antiinflammatory drug. Combined electroporation with iontophoresis was shown to provide rapidly responsive transdermal transport of luteinizing hormone releasing hormone ex vivo as well. These data underline the potential of skin electroporation for improving the delivery profile of existing conventional transdermal patches, but also for replacing the injectable route.High-voltage pulses can increase drug permeation within and across skin but are also an efficient tool to permeabilize the membrane of cells of the cutaneous or subcutaneous tissue. This was shown beneficial for targeting cutaneous cells with oligonucleotides or genes and might open new opportunities for gene therapy and DNA vaccination.The safety of the application of high-voltage pulses on skin was assessed in vivo, using histological and visual scores, and bioengineering methods. While changes in skin barrier and function were observed, the irritation was mild and short-lived. Further optimization of the electrode configuration for improved targeting of the stratum corneum should still improve tolerance and levels of sensation.

Journal Article↗

Effects of iontophoresis and electroporation on the stratum corneum. Review of the biophysical studies.

This review focuses on the effects induced by iontophoresis and electroporation on the stratum corneum of the skin. Hence, the aims were: (1) to contribute to the understanding of the mechanisms of drug transport by these methods; (2) to evaluate the safety issues associated with current application. Complementary biophysical methods were used to provide a complete picture of the stratum corneum. Even though the mechanism of drug transport is believed to be different, i.e., electrophoresis for iontophoresis and creation of new aqueous pathways for electroporation, the effects on the stratum corneum detected minutes after current application are very similar. For both methods, the major findings were: (1) a disorganisation of the lipid bilayers of the stratum corneum; (2) an increase in skin hydration; (3) a larger decrease in skin resistance induced by electroporation as compared to iontophoresis. These changes were partly reversible and depended on the amount of electrical charges transferred. The mechanisms of stratum corneum perturbations are discussed. These perturbations could explain partly the increase in drug transport. If iontophoresis is considered as a safe method of drug delivery, the data augurs for the safety of electroporation.

Journal Article↗

Intranasal immunization against influenza virus using polymeric particles.

The aim of this study was to evaluate the potential of poly(D,L-lactide-co-glycolide) nano-and microspheres, with a mean diameter of 220 nm and 8 microm, respectively, to enhance the nasal and systemic immune responses against influenza virus antigen. High encapsulation levels of antigen were achieved in all cases. Neither the molecular weight nor the antigenicity of the entrapped antigen were affected by the encapsulation procedure. Following nasal immunization, the nasal washes IgA and the serum IgG responses were evaluated. With the soluble antigen, relatively high immune responses were observed. With nanospheres, nasal washes IgA levels were significantly lower (p<0.01) and serum IgG levels were not significantly different (p>0.05) from those obtained with the soluble antigen. With microspheres, both nasal washes IgA and serum IgG levels were significantly lower (p<0.01 and <0.05, respectively) as compared to the levels found for the soluble antigen. In addition, fluorescent microspheres administered intranasally failed to reach the nasal-associated lymphoid tissue (NALT). This lack of particle uptake by NALT and the high immunogenicity of the antigen used in this study, could explain the absence of enhancement of the immune responses by the polymeric particles.

Administration, Intranasal↗

Transdermal permeation of neutral molecules by skin electroporation.

Electroporation of skin has recently been shown to enhance transport of charged molecules across skin by up to four orders of magnitude. This study demonstrates that high-voltage pulses can also increase transdermal permeation of two neutral model solutes, i.e. mannitol and water, up to 100-fold. The elevated flux results from the persistent increase in skin permeability following electroporation, rather than from electro-osmosis during pulsing. Control on transport was achieved by controlling the electrical parameters of the pulse, i.e. the pulse voltage, time constant and number.

Animals↗

Transdermal alniditan delivery by skin electroporation.

The aim of this study was to evaluate the transdermal permeation of alniditan by electroporation and to compare with iontophoretic delivery. The influence of the electrical parameters of electroporation was investigated in vitro using a factorial design study. The transdermal flux of alniditan was enhanced by two orders of magnitude by application of high voltage electrical pulses. The electrical parameters of electroporation-i.e. the voltage, the duration and the number of pulses-allowed a control of drug permeation. Both transport during and after pulsing were shown to be important for alniditan transdermal delivery by electroporation. Electroporation was found more efficient in promoting alniditan permeation than an iontophoresis transferring the same amount of charges.

Administration, Cutaneous↗

Transdermal delivery of fentanyl: rapid onset of analgesia using skin electroporation.

Skin electroporation has recently been shown to increase transdermal transport of small-size drugs as well as considerably larger molecules by up to 4 orders of magnitude in vitro. Nevertheless, no in vivo studies have proven that high-voltage pulses can induce therapeutic plasma levels of drug. The aim of the present report was precisely to study the potential of skin electroporation in transdermal delivery of fentanyl in vivo. Fentanyl was transdermally delivered to hairless rats using high-voltage pulsing. Following the administration, the pharmacokinetics and pharmacodynamics were assessed. Significant fentanyl plasma concentrations were rapidly achieved using skin electroporation. Immediately after the 5 min pulsing, fentanyl plasma levels reached one third of the maximal plasma concentration of approximately 30 ng/ml, the peak occurring 30 min after the electroporation. Deep analgesia and supraspinal effects were achieved, antinociception lasting for an hour. The magnitude of the effects was, however, dependent on the electrical parameters of the pulses.

Administration, Cutaneous↗