PubMed Health⌕ Search

Biomedical subjects

V Pucci

Publications and source records attributed to V Pucci.

23 records · Page 2Linked to original sources

Transscleral diode laser photocoagulation in refractory glaucoma.

BACKGROUND AND OBJECTIVE: Patients with glaucoma refractory to medical or surgical treatment are difficult to treat. The aim of this study was to evaluate the effect of contact transscleral diode laser cyclophotocoagulation (DLPC) on these patients' intra-ocular pressure (IOP) and visual acuity. PATIENTS AND METHODS: 37 eyes of 36 patients who suffered from refractory glaucoma and who had undergone DLPC, were followed at the Eye Clinic of Verona University for an average of 14 +/- 4 months. The average age was 54 +/- 26 years. IOP, visual acuity and ocular complications were analysed. RESULTS: A total of 71 treatments were given. More than 1 treatment was given in 22 eyes (59%). The mean pretreatment IOP was 33.1 +/- 3.3 mm Hg. At the last follow-up, the mean IOP was 21 +/- 1.6 mm Hg. Mean total medications were reduced from 4.4 +/- 0.5 to 2.4 +/- 0.3. No serious complications occurred in 71 treatments. Visual acuity remained stable in 25 eyes (67.5%), improved in 6 eyes (16.2%) and decreased in 6 eyes (16.2%). CONCLUSIONS: DLPC is effective in lowering IOP in eyes with refractory glaucoma. It also serves to reduce the number of antiglaucoma medications. This procedure is relatively safe. Nevertheless, multiple DLPC applications may be needed.

Adolescent↗

Simultaneous determination of all-trans-retinoic acid, beta-carotene, and vitamin A in galenic preparations by liquid chromatography.

The concentrations of vitamin A, beta-carotene, and all-trans-retinoic acid in oral preparations were determined in a single analysis by a method based on isocratic, reversed-phase liquid chromatography (LC). The LC system consisted of a C18 column, a mobile phase of acetonitrile, dichloromethane, methanol, and water and a UV detector set at 330 nm. The linearity ranges were 25-250 ng/mL for trans-retinoic acid and vitamin A, and 100-1,000 ng/mL for beta-carotene. This LC method for the determination of retinoids is simple, precise, and accurate. No extraction procedure is required before the chromatographic analysis; only a suitable dilution is necessary. The method proved to be reliable, fast, and economical. Furthermore, this method is indicative of stability, because it allows for the determination of degradation products such as 13-cis-retinoic acid.

Chromatography, Liquid↗

Comparison of three analytical methods for quality control of clozapine tablets.

Three different analytical methods for the quality control of clozapine in commercial formulations were developed and compared: a liquid chromatographic (LC) method with UV detection, a capillary zone electrophoretic (CZE) method, and a linear scan voltammetric (LSV) method. The isocratic LC procedure used a C18 reversed-phase column; the CZE method used an uncoated fused-silica capillary and phosphate buffer containing polyvinylpyrrolidone as the background electrolyte; the LSV method analyzed clozapine solutions with acidic phosphate buffer as the supporting electrolyte. The 3 methods gave similar and satisfactory results, in terms of precision and accuracy. Repeatability and intermediate precision were good (RSD% < 2.2) and accuracy, resulting from recovery studies, was between 98 and 102%. The rapidity of analysis was high for all 3 methods, especially for the LSV.

Antipsychotic Agents↗

[Adenotonsillectomy: the evaluation of the long-term results after more than 7 years from the intervention].

A study was carried out on 110 patients with various diseases related to chronic inflammation of the tonsils and to hypertrophic adenoids. Sixty-two of these patients underwent adenotonsillectomy, while the others were followed clinically and, where necessary, given medical treatment. At the first observation the patients were between the ages of 2 and 12 (mean age 6.1 years). At the start of the present study the patients ages ranged from 10 to 22 (mean age 17 years). Clinical follow-up was carried out on the patients 2 and 7 years after the first observation and/or adenotonsillectomy. The patients were divided into homogeneous groups according to the severity of symptoms. The A.A. evaluated changes of the following clinical parameters: annual frequency of inflammatory pharyngotonsillar episodes, nasal respiratory obstruction, sore throat, otologic pathology. Evaluations were carried out statistically in each group. After more than 7 years from surgery, the significant reduction of various diseases related to chronic inflammation of the tonsils and to hypertrophic adenoids, in accordance with the findings after 2 years from surgery, underline the effectiveness of adenotonsillectomy in correctly selected candidates.

Adenoidectomy↗

CO2 laser in laryngeal microsurgery.

The CO2 Laser is used in the treatment of several laryngeal diseases and offers considerable advantages over traditional techniques. New applications of this surgical tool are currently under study for other laryngeal and ENT pathologies. It should be pointed out that there are some limitations to the use of the CO2 Laser; an accurate examination of its indications is needed, as well as a precise knowledge of its techniques and possibilities.

Carcinoma↗