Improvised automatic lung ventilation for unanticipated emergencies.

OBJECTIVES: To design an improvised circuit that can be used to extend the capability of a single ventilator to ventilate two or more patients and that can be assembled from readily available parts in times of unanticipated emergency. DESIGN: Research and development, followed by technical analysis and evaluation. SETTING: Biomedical laboratory. MEASUREMENTS AND MAIN RESULTS: We describe two circuits that can be assembled from readily available inexpensive components to function as improvised ventilators. One circuit requires only a central mushroom valve driver and an additional source of fresh gas for each patient. The other circuit is configured as a number of secondary circuits in parallel, connected to a single ventilator. We constructed and tested the circuits using mechanical lung simulators. The secondary circuit configuration was more efficient in terms of fresh gas usage, but was more complex regarding operation and trouble-shooting. CONCLUSIONS: These two improvised circuits can extend the capability of a standard volume-cycled ventilator to provide automatic ventilation of the lungs in times of disaster.

Emergencies↗

Effect of supplemental nocturnal oxygen on gas exchange in patients with severe obstructive lung disease.

We studied the effect of supplemental nocturnal oxygen on blood gases in 15 patients with severe but stable chronic obstructive lung disease (ratio of forced expired volume in one second to forced vital capacity, 37.2 +/- 1.8 [mean +/- S.E.] per cent of predicted; arterial oxygen tension, 50.7 +/- 1.4 mm Hg; and arterial carbon dioxide tension [PCO2], 53.1 +/- 1.5 mm Hg). Sleep variables and measures of gas exchange were determined on two consecutive nights; on the first night the subjects breathed supplemental oxygen, and on the second they breathed room air. Transcutaneous PCO2 was measured with an infrared sensor, and arterial oxygen saturation with an ear oximeter. Breathing of supplemental oxygen sufficient to keep oxygen saturation at or above 90 per cent was associated with only small increases (less than 6 mm Hg) in PCO2 throughout sleep, as compared with values while subjects were breathing room air. The increase in PCO2 occurred early in the night and was not progressive. Only three patients, who were found to have obstructive sleep apnea in addition to obstructive lung disease, had larger increases in PCO2 during sleep and reported morning headaches. We conclude that nocturnal oxygen does not induce clinically important increases in PCO2 during sleep in patients with stable obstructive lung disease and therefore can safely be used to prevent the dangerous consequences of hypoxia.

Aged↗

Transcutaneous carbon dioxide monitoring.

We studied changes in transcutaneous PCO2 in healthy volunteers and patients to establish the accuracy and practicability of a new cutaneous capnometer (HP47201A). In 9 healthy volunteers, as many as 4 experiments each were performed during each laboratory session. After cutaneous electrode stabilization, a gas mixture of CO2 in O2 was rebreathed under "open-loop" conditions allowing a rapid progressive increase in alveolar PCO2. The electrode stabilized on the skin with a time constant of 2.87 +/- 0.72 min. During rebreathing, alveolar PCO2 increased 4.25 +/- 0.63mm Hg/min. The simultaneous rate of increase in transcutaneous PCO2 was 2.91 +/- 0.59 mm Hg of CO2/min. Electrode response was also studied during steady-state conditions after a step increase in alveolar PCO2 of 10 mm Hg more than the resting end-tidal PCO2. The time constant of the skin electrode's response under these conditions was 3.2 +/- 1.9 min. We compared the arterial PCO2 of 25 blood samples with simultaneous transcutaneous PCO2 measurements in hemodynamically and metabolically stable patients. The range of arterial PCO2 values varied between 24 and 98 mm Hg, and the electrode remained stable during each 12-h study. Observed values closely approximated arterial PCO2 measurements, with transcutaneous readings 4 mm Hg more than measured arterial values (r = 0.98). We conclude that the cutaneous capnometer accurately and consistently reflects arterial PCO2 and has delay and response characteristics that may allow its use in clinical monitoring of patients.

Adult↗

Decrease in lung recoil pressure after cessation of smoking.

Tests of lung mechanics and single-breath carbon monoxide diffusing capacity (DLCO) were done in 26 apparently healthy cigarette smokers before and 2 months after cessation of smoking. There was a significant increase in vital capacity and 1-sec forced expiratory volume as well as improvement in frequency dependence of lung dynamic compliance. Slope and phase III and density dependence of maximal expiratory flow showed a borderline improvement DLCO did not change. Static lung pressure-volume curves showed a small but significant (P less than 0.01) shift toward lower pressures. We concluded that the previously reported decrease in lung recoil pressure observed in smokers is even more accentuated after cessation of smoking.

Adult↗