PubMed Health⌕ Search

Biomedical subjects

V S Venturella

Publications and source records attributed to V S Venturella.

12 recordsLinked to original sources

Simultaneous determination of phenolphthalein and phenolphthalein glucuronide from dog serum, urine and bile by high-performance liquid chromatography.

A procedure is described to simultaneously quantitate phenolphthalein and its glucuronide metabolite from dog serum, urine and bile using high-performance liquid chromatography. The major advantages of this over pre-existing methods include direct analysis of the parent compound and glucuronide metabolite without enzymatic hydrolysis, increased sensitivity and the potential for automation of a large number of samples. Analytes were extracted from serum and urine using a combination of liquid- and solid-phase extraction methodology. Bile samples were analyzed directly after a twenty-fold dilution with mobile phase. The components plus internal standard were separated by reversed-phase high-performance liquid chromatography using step gradient elution and quantitated by the absorbance of ultraviolet light at 230 nm. Limits of detection from 1 ml of serum, 0.1 ml of urine and 0.05 ml of bile were 0.1, 0.5 and 10 microgram/ml for phenolphthalein and 0.1, 10 and 50 microgram/ml for phenolphthalein glucuronide, respectively.

Animals↗

Determination of [3H]brifentanil, a potent narcotic analgesic, from rat serum by high-performance liquid chromatography with on-line radioactive detection.

A method for rapid analysis of [3H]brifentanil extracted from rat serum is described that has the advantages of sensitivity, speed and specificity. The method is based on extraction from serum via solid-phase extraction followed by chromatographic separation on a reversed-phase high-performance liquid chromatographic column. Detection of [3H]brifentanil is accomplished with an on-line radioactive detector, thus the laborious step of peak collection and subsequent liquid scintillation counting is eliminated. The developed method is sensitive to 0.1 ng/ml and has been successfully applied to pharmacokinetic studies in rats. In vivo metabolites retaining the radiolabel have been detected with the method and were more polar than the parent compound as based upon the elution order on the reversed-phase system.

Analgesics↗

Sensitive method for the determination of pentamorphone in serum by liquid chromatography-mass spectrometry with thermospray interface.

A liquid chromatographic-mass spectrometric method for the determination of 14-beta-n-pentylaminomorphinone (pentamorphone) and 14-beta-n-pentylaminocodeinone (PAC) as internal standard is developed. Concentration levels in serum were calculated by the ratio of the peak areas of pentamorphone to PAC versus the concentration of pentamorphone. Peak areas were measured using selected-ion-recording of the pseudo-molecular ions of pentamorphone and PAC (m/z 369 and m/z 383, respectively). Aliquots (50 microliters) of sample were injected on a C18 mu Bondapak column following solid-phase extraction. The lowest limit of quantitation observed was 43 pg/ml. The sensitivity, accuracy and reproducibility of the method were demonstrated to be satisfactory for application in pharmacokinetic study of pentamorphone.

Analgesics↗