PubMed Health⌕ Search

Biomedical subjects

V V Cosofret

Publications and source records attributed to V V Cosofret.

7 recordsLinked to original sources

A conducting salt-based amperometric biosensor for measurement of extracellular lactate accumulation in ischemic myocardium.

In this paper, fabrication, characterization, and physiological application of a miniaturized amperometric lactate biosensor are described. The sensor is based on cross-linked lactate oxidase and tetrathiafulvalene-tetracyano-quinodimethane (TTF-TCNQ) charge transfer complex. The sensor was developed for continuous quantitative measurement of the lactate accumulation in ischemic myocardium under severe depletion of oxygen. The sensor was evaluated in vitro at an applied potential of 0.15 V vs Ag/AgCl; it proved to combine all the performance characteristics desired for the present application, such as proper response in absence of oxygen, good operational stability, good accuracy and precision (103.5 +/- 1.2%), adequate response time (t95% = 80 s), and wide linear dynamic range up to 27 mM (r = 0.9998) in N2-saturated solutions and at 37 degrees C. The prepared sensors (n = 12) showed sensitivity of 380 +/- 90 nA/mM, and a background current of 240 +/- 50 nA. The lower limit of detection is 0.4 +/- 0.15 mM with a S/N ratio equal to 3. Results obtained for direct lactate monitoring in ischemic rabbit papillary muscle under no-flow conditions and PO2 < 6 mm Hg are presented.

Animals↗

Ion-selective membranes with low plasticizer content: electroanalytical characterization and biocompatibility studies.

High molecular weight poly(vinyl chloride) and aliphatic polyurethane (Tecoflex)-based ion selective membranes, with normal and reduced amounts of plasticizer, as well as without plasticizer, were tested with respect to their analytical properties, their biocompatibility, and cellular responses. The analytical properties of the membranes did not change significantly within a wide range of polymer to plasticizer ratios. However, the membranes with reduced plasticizer content had better adhesive properties, less anion interference, extended life time, and better biocompatibility. Using the cage implant system, the results showed that an increase of plasticizer weight percent in Tecoflex membranes correlated positively with the increase in host inflammatory response up to 14 days of implantation. The results also demonstrated that both PVC and Tecoflex-based ion-selective membranes with the most common membrane composition (1:2 polymer to plasticizer ratio) exhibited a similar acute inflammatory response, but the PVC-based membrane elicited a reduced chronic inflammatory response when compared with the Tecoflex-based membrane.

Adhesiveness↗

Electroanalytical and biocompatibility studies on carboxylated poly(vinyl chloride) membranes for microfabricated array sensors.

Potassium ion-selective and pH membrane electrodes based on neutral carrier ionophores for K+ (valinomycin) and H+ (TDDA and ETH 5294), respectively, immobilized in carboxylated PVC (PVC-COOH) with normal (classical) and reduced amounts of plasticizer, were investigated with respect to their general analytical performances (linear range, slope, detection limit, selectivity, internal membrane resistance), their biocompatibility and cellular responses. The analytical performance of potassium selective electrodes was not affected by reducing the plasticizer content from 66% (m/m) to about 33% (m/m) while that of pH electrodes was significantly changed at the lower plasticizer concentration level. The adhesive properties of PVC-COOH membranes to an inert substrate such as polyimide-coated Kapton are greatly improved by reducing the plasticizer content of the membrane. In addition, as was reported earlier by this group, improved biocompatibility was observed with these membranes relative to those with increased plasticizer content. A ratio of 1:1 m/m for PVC-COOH to plasticizer is recommended for the construction of planar ISEs without massive use of internal solution.

Animals↗

A quinidine-responsive plastic membrane electrode.

A membrane electrode based on quinidine tetraphenylborate in a PVC matrix is described. The electrode exhibits a rapid and near-Nernstian response in the range 3.5 x 10(-5)-1 x 10(-2) M quinidine sulphate at pH 6-8. In an acidic medium the electrode responds to diprotonated quinidine. In sodium tetraphenylboron (Na TPB) solutions the response is linear in respect of log (TPB-) over the range 10(-4)-10(-2)M . Direct potentiometry and potentiometric titrations are used to determine quinidine in pharmaceutical preparations.

Journal Article↗