PubMed Health⌕ Search

Biomedical subjects

V V Kondratenko

Publications and source records attributed to V V Kondratenko.

4 recordsLinked to original sources

Nanoimaging with a compact extreme-ultraviolet laser.

Images with a spatial resolution of 120-150 nm were obtained with 46.9 nm light from a compact capillary-discharge laser by use of the combination of a Sc-Si multilayer-coated Schwarzschild condenser and a free-standing imaging zone plate. The results are relevant to the development of compact extreme-ultraviolet laser-based imaging tools for nanoscience and nanotechnology.

Equipment Design↗

Damage to extreme-ultraviolet Sc/Si multilayer mirrors exposed to intense 46.9-nm laser pulses.

The damage threshold and damage mechanism of extreme-ultraviolet Sc/Si multilayer mirror coatings are investigated with focused nanosecond pulses at 46.9-nm radiation from a compact capillary-discharge laser. Damage threshold fluences of approximately 0.08 J/cm2 are measured for coatings deposited on both borosilicate glass and Si substrates. The use of scanning and transmission electron microscopy and small-angle x-ray diffraction techniques reveals the thermal nature of the damage mechanism. The results are relevant to the use of newly developed high-flux extreme-ultraviolet sources in applications.

Journal Article↗

Efficient method for the determination of extreme-ultraviolet optical constants in reactive materials: application to scandium and titanium.

The chemical reaction of a sample with atmospheric gases causes a significant error in the determinantion of the complex refractive index n = 1 - delta + ibeta in the extreme-ultraviolet region. The protection of samples removes this effect but hampers the interpretation of measurements. To overcome this difficulty, we derive the exact dependences on film thickness of the reflectivity and transmissivity of a protected film. These dependences greatly simplify the determination of delta and beta when the spectra of several films with different thickness and identical protection are measured. They also allow the verification of the delta(omega) obtained from the Kramers-Kronig relation and even make the Kramers-Kronig method unnecessary in many cases. As a practical application, the optical constants of Sc and Ti are determined at h omega = 18-70 eV and 18-99 eV, respectively. The essential feature of our experimental technique is deposition of a film sample directly on a silicon photodiode that allows easy operation with both thin (approximately 10-nm) and thick (approximately 100-nm) films. The comparison of calculated reflectivities of Si-Sc multilayers with the measured values shows the high accuracy of the determined delta(omega) and beta(omega).

Journal Article↗

Skylab 3600 groove/mm replica grating with a scandium-silicon multilayer coating and high normal-incidence efficiency at 38-nm wavelength.

A Sc-Si multilayer coating was applied to a replica of the 3600 groove/mm grating, developed for the SO82A spectroheliograph that flew on the Skylab mission, for the purpose of enhancing the normal-incidence efficiency in the extreme-ultraviolet region. The efficiency, measured at an angle of incidence of 6 degrees with synchrotron radiation, had a maximum value of 7.2% at a wavelength of 38 nm and was a factor of 3 higher than the efficiency of the gold-coated Skylab grating. The measured efficiency of the Sc-Si grating was in good agreement with the efficiency calculated by use of the modified integral method.

Journal Article↗